Recent advances in medical X-ray imaging have enabled the development of new techniques capable of assessing not only bone quantity but also structure. This article provides (a) a brief review of the current X-ray methods used for quantitative assessment of the skeleton, (b) data on the levels of radiation exposure associated with these methods and (c) information about radiation safety issues. Radiation doses associated with dual-energy X-ray absorptiometry are very low. However, as with any X-ray imaging technique, each particular examination must always be clinically justified. When an examination is justified, the emphasis must be on dose optimisation of imaging protocols. Dose optimisation is more important for paediatric examinations because children are more vulnerable to radiation than adults. Methods based on multi-detector CT (MDCT) are associated with higher radiation doses. New 3D volumetric hip and spine quantitative computed tomography (QCT) techniques and high-resolution MDCT for evaluation of bone structure deliver doses to patients from 1 to 3 mSv. Low-dose protocols are needed to reduce radiation exposure from these methods and minimise associated health risks.
1 September 2003 in Journal of Bone and Joint Surgery
Background: Personnel assisting in or performing fluoroscopically guided procedures may be exposed to high doses of radiation. Accurate occupational dosimetric data for the orthopaedic theater staff are of paramount importance for practicing radiation safety.
Background — The aim of the current study was to estimate the conceptus radiation dose and risk associated with fluoroscopic imaging during a catheter ablation procedure for supraventricular tachycardia performed on the expectant mother. Methods and Results — Exposure parameters and fluoroscopy times for each projection of the cardiac ablation procedure performed in 20 female patients of childbearing age were recorded. Radiation doses for a potential conceptus were estimated by using dose data obtained in anthropomorphic phantoms simulating pregnancy at the first, second, and third trimesters. Dose measurements were carried out using thermoluminescent dosimeters. For a typical examination, the average radiation dose to the conceptus was <1 mGy in all periods of gestation. Average excess fatal cancer was 14.5/10 6 unborn children irradiated during the first postconception weeks. Corresponding values for the second and third trimesters were 30 and 55.7/10 6 , respectively. The risk for hereditary effects in future generations was 1.5/10 6 cases for conceptus irradiation during the first postconception weeks. Corresponding values for the second and third trimesters were 3.0 and 5.6/10 6 , respectively. Formulas and dose data are presented for estimating the conceptus risk from any technique and x-ray system used for catheter ablation procedures. Conclusions — A typical catheter ablation procedure results in a very small increase in risk of harmful effects to the conceptus. However, estimation of conceptus dose from catheter ablation procedures is always needed to assess the risk to the individual developing in utero.
Although the Diagnostic Reference Levels (DRLs) have been shown to be an important tool for optimising patient radiation protection, there are still difficulties related to the methodology that should be used to establish and use local DRL values. This statement represents the current view of the EuroSafe Imaging ‘Clinical DRLs’ working group formed with the purpose to produce scientific and educational material on DRLs and promote the concept of local DRLs. Guidelines on how to establish and how to use local DRLs presented herein can be implemented using a multidisciplinary team approach. Local DRLs are easy to determine and implement and they reflect local equipment performance and local clinical needs. They can be updated more frequently than the national DRLs, especially if a dose management system is available. To establish local DRLs, a practical approach could be to collect a reasonable set, i.e., at least 20–30 procedures, of data for well-defined clinical indications and calculate the 3rd quartile values. The median values of the distribution can be set to define the ‘typical values’. The International Commission of Radiological Protection (ICRP) suggests setting ‘typical values’ for newer technologies that enable decreased amounts of radiation exposure for a similar level of image quality. Local DRLs should be similar or lower to the national DRLs. They could be higher only if the clinical benefits for some medical indications are fully explained and reported. Local DRLs may be used as a quality benchmark to track outliers and can be also used as alert values.