Capacitive-coupling inverters (CCIs) have low operation voltage and enhanced reactive power control capability. It is a promising alternative to provide reactive power and voltage regulation in microgrids (MGs). Droop control is one of the most widely used primary controllers under a hierarchical framework in an MG. However, conventional droop control performance needs improvement since the droop curve assumption is not valid in part of CCI's operational area. At the same time, reactive power sharing error due to the uncertainty factor of feeder impedance needs to be minimized. In this article, virtual-impedance droop control is proposed for CCIs to solve the two issues. A virtual impedance selection method is developed with consideration of CCI's second-order LC coupling branch. First, the virtual impedance is selected for reducing the coupling between the active and reactive power of CCIs. The stability and sensitivity of the system are also evaluated based on a small-signal model to provide guidelines for virtual impedance selection. The proposed control varies the equivalent impedance via a feedback loop in CCI's control for accurate power control and sharing in MGs under mismatched feeder impedance. The validity of the proposed virtual-impedance droop control is verified through simulation and experimental results.
Hydrogen energy, as a zero-carbon emission type of energy, is playing a significant role in the development of future electricity power systems. Coordinated operation of hydrogen and electricity will change the direction and shape of energy utilization in the power grid. To address the evolving power system and promote sustainable hydrogen energy development, this paper initially examines hydrogen preparation and storage techniques, summarizes current research and development challenges, and introduces several key technologies for hydrogen energy application in power systems. These include hydrogen electrification technology, hydrogen-based medium- and long-term energy storage, and hydrogen auxiliary services. This paper also analyzes several typical modes of hydrogen–electricity coupling. Finally, the future development direction of hydrogen energy in power systems is discussed, focusing on key issues such as cost, storage, and optimization.
8 October 2025 in International Journal of Electrical Power & Energy Systems
With the advantages of the low cost of transmission lines and high efficiency, the DC microgrid has become a rising star in the low‐voltage network. However, multi‐source and multi‐transformation characteristics in DC microgrids will lead to the existence of various forms of ripple generation sources in the system. The existence of a large amount of ripple not only directly cause the reduction of power quality of DC microgrids, but also decreases the accuracy of electricity billing. It is vital to achieving accurate ripple detection for the reliable power supply of the DC microgrid. A DC‐side ripple detection method, which combines the Whale Optimization Algorithm (WOA), Variational Modal Decomposition (VMD), and Hilbert Transform (HT), is therefore investigated and proposed here. Firstly, the sample entropy (SampEn) is used as the fitness function, applied the whale optimization algorithm, is to determine the optimal decomposition scale and penalty factor, of the variational modal decomposition; then, the ripple‐containing DC signal is decomposed into a series of eigenmodal components (imf) by the optimized variational modal decomposition algorithm. Finally, the Hilbert Transform is performed to obtain the amplitude and frequency of the ripple components. To prove the effectiveness, the proposed method is compared with the conventional Empirical Mode Decomposition (EMD) and the VMD algorithm, by testing simulated DC signals without and with noise. Results show that the proposed method has higher accuracy and noise robustness than the EMD and VMD algorithms.
23 May 2026 in International Journal of Electrical Power & Energy Systems
Compared with the traditional solution, the microgrid (MG) employed capacitive coupling inverters (CCIs) with higher reactive power capacity can effectively reduce the probability of low voltage. However, because of the special coupling structure, different power flow control methods will greatly affect the cost and operation efficiency of the CCI. A multi‐layer and timescale optimal power flow control considering inverter‐layer is therefore proposed in this paper. Firstly, the power output characteristics of CCI are analyzed, and the power flow control model of CCI with an energy storage unit is established. Secondly, an optimal control method on different timescales was proposed. By coordinating the active power output and the reserved charging state margin of the energy storage unit, the CCI‐MG reactive power regulation with the most economical and minimum loss was realized, so as to achieve long‐term voltage stability and dynamic satisfaction of load demands. Furthermore, the optimal power flow control of CCI is proposed. The simulation results show that the proposed method can effectively realize the optimal control of active and reactive power of MG, and also improve the voltage stability of AC bus under the economical operation of CCI.