Yeo Jin Kim

Yeo Jin Kim

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
SCSanghyun Cho
Sanghyun Cho
HYHyun Jung Yoon
Hyun Jung Yoon
YLYoung Lee
Young Lee
IKInjoong Kim
Injoong Kim
JGJe Ryung Gil
Je Ryung Gil
YKYeo Jin Kim
Yeo Jin Kim
Background: Fluoroscopy-guided PTNB for fluoroscopy-identifiable lung lesions has been suggested as a useful method for the pathological diagnosis of lung lesions; however, it is lacking in accuracy and safety compared to CT-guided PTNB. Thus, we aimed to investigate the diagnostic accuracy and complications of fluoroscopy-guided percutaneous transthoracic needle biopsy (PTNB) with the aid of pre-procedural planning cone-beam computed tomography (CBCT) in order to take advantage of their respective strengths. Methods: A total of 255 fluoroscopy-guided PTNBs with the aid of planning CBCT were performed. Pre-procedural planning CBCT was conducted to calculate the shortest length from the skin puncture site to the margin of the target lesion for the needle trajectory. No intra-procedural CBCT was performed. The diagnostic performance of fluoroscopy-guided PTNB with the aid of planning CBCT was calculated. The prognostic factors for diagnostic failures and complications were evaluated using logistic regression analysis. Results: The accuracy, sensitivity, specificity, PPV, and NPV were 97.3%, 88.0%, 90.9%, 100%, and 62.5%, respectively. There were 29 diagnostic failures (11.8%), and the multivariable analysis showed that a longer lesion depth on CBCT and a shorter specimen length were each associated with diagnostic failure (p = 0.010 and 0.012, respectively). Complications occurred in 34 PTNBs (13.3%). The multivariable analysis showed that an increased total number of biopsies per lesion, a longer length of lung aeration via needle insertion, a smaller lesion size on CT imaging (≤20 mm), and the presence of an air bronchogram were associated with the occurrence of complications (p = 0.027, <0.001, 0.003, and 0.020, respectively). Conclusions: Excellent diagnostic accuracy was obtained by fluoroscopy-guided PTNB with the aid of planning CBCT. Compared to that of CT- or CBCT-guided PTNB, the procedure-related complication rate was acceptably low, but the radiation dose to patients could be potentially reduced.

1 January 2024 in Journal of the Korean Society of Radiology
Verified
Journal Article
Open access
PDF file
SYSeong Hee Yeo
Seong Hee Yeo
HYHyun Jung Yoon
Hyun Jung Yoon
IKInjoong Kim
Injoong Kim
YKYeo Jin Kim
Yeo Jin Kim
YLYoung Lee
Young Lee
SBSo Hyeon Bak
So Hyeon Bak
여성희, et al. J Korean Soc Radiol. 2024 Mar;85(2):394-408. https://doi.org/10.3348/jksr.2023.0011

1 January 2026 in Journal of the Korean Society of Radiology
Verified
Journal Article
Open access
PDF file
YSYun Kyoung Shin
Yun Kyoung Shin
JGJe Ryung Gil
Je Ryung Gil
HYHyun Jung Yoon
Hyun Jung Yoon
YKYeo Jin Kim
Yeo Jin Kim
신윤경, et al. J Korean Soc Radiol. 2026 ;87:e7. https://doi.org/10.3348/jksr.2024.0103

1 January 2026 in Journal of the Korean Society of Radiology
Verified
Journal Article
Open access
YSYun Kyoung Shin
Yun Kyoung Shin
YKYeo Jin Kim
Yeo Jin Kim
JGJe Ryung Gil
Je Ryung Gil
HYHyun Jung Yoon
Hyun Jung Yoon