Aims: Several large studies have documented the outcome of transvenous lead extraction (TLE), focusing on laser and mechanical methods. To date there has been no large series addressing the results obtained with rotational lead extraction tools. This retrospective multicentre study was designed to investigate the outcomes of mechanical and rotational techniques. Methods and results: Data were collected on a total of 2205 patients (age 66.0 ± 15.7 years) with 3849 leads targeted for extraction in six European lead extraction centres. The commonest indication was infection (46%). The targeted leads included 2879 pacemaker leads (74.8%), 949 implantable cardioverter-defibrillator leads (24.6%), and 21 leads for which details were unknown; 46.6% of leads were passive fixation leads. The median lead dwell time was 74 months [interquartile range (IQR) 41–112]. Clinical success was obtained in 97.0% of procedures, and complete extraction was achieved for 96.5% of leads. Major complications occurred in 22/2205 procedures (1%), with a peri-operative or procedure-related mortality rate of 4/2205 (0.18%). Minor complications occurred in 3.1% of procedures. A total of 1552 leads (in 992 patients) with a median dwell time of 106 months (IQR 66–145) were extracted using the Evolution rotational TLE tool. In this subgroup, complete success was obtained for 95.2% of leads with a procedural mortality rate of 0.4%. Conclusion: Patient outcomes in the PROMET study compare favourably with other large TLE trials, underlining the capability of rotational TLE tools and techniques to match laser methods in efficacy and surpass them in safety.
Aims: Cardiac implantable electronic device (CIED) infection rates are increasing. Worldwide compliance and disparities to published guidelines for the prevention, diagnosis and management of these conditions are not well elucidated. The purpose of this survey, therefore, was to clarify these issues through an inquiry to arrhythmia-related associations and societies worldwide. Methods and results: A questionnaire comprising 15 questions related to CIED infections was distributed among members of seven arrhythmia societies worldwide. A total of 234 centres in 62 countries reported implantation rates of which 159 (68.0%) performed more than 200 device implantations per year and 14 (6.0%) performed fewer than 50 implantations per year. The reported rates of CIED infections for 2017 were ≤2% in 78.7% of the centres, while the infection rates exceeded 5% in 7.8% of the centres. Preventive measures for CIED infection differed from published recommendations and varied among different regions mainly in terms of pocket irrigation and administering post-operative antimicrobial therapy the use of which was reported by 39.9% and 44% of the respondents, respectively. Antibacterial envelopes were used by 37.7% of the respondents in selected circumstances. In terms of pocket infection management, 62% of the respondents applied complete system removal as an initial step. Diagnostic pocket needle aspiration and pocket surgical debridement were reported by 15.8% and 11.8% of centres, respectively. Conclusion: Clinical practices for prevention and management of CIED do not fully comply with current recommendations and demonstrate considerable regional disparities. Further education and programmes for improved implementation of guidelines are mandatory.
Upon cardiac implantable electronic device (CIED) exchange, upgrade, or revision surgery patients are exposed to a considerable risk of adverse events. The presence of firm fibrotic tissue endangers these procedures. Leads can be damaged in the attempt of freeing them from fibrotic tissue. Hematoma can form as result of capsulectomy, pocket debridement and leads dissection. Due to the increasing number of CIED exchange, upgrade and revision surgeries, the incidence of related complications is expected to rise in the near future.The aim of the study was to evaluate the feasibility, safety, and performance of a rationally micro-engineered non-resorbable biosynthesized cellulose (BC) membrane as conformal wrapping protection around CIED implants. Protective membranes were generated by means of a recently established method to transfer on-demand microscale geometries onto the surface of BC. A chronic minipig animal model was selected to investigate the performance of the BC anti-fibrotic protection, directly measured as reduction of fibrotic tissue formation. Sixteen (n = 16) animals received each one BC coated pacemaker (PMC) and one native pacemaker (BI) at equivalent anatomical sites. BC protective layers were juxtaposed around pacemakers through a fast and well-repeatable procedure. Explants were performed at 3 and 12 months after implantation. Endpoint analysis showed that the BC protective layers were 100% integer, with no sign of chemical or mechanical degradation and appeared as a thin layer of white-tan material, adherent to the surrounding thin fibrous capsule, from which it could be peeled off by gently pulling with forceps. The protective effect of micro-engineered BC yielded an average thickness reduction of 66% of the fibrotic tissue thickness generated around PMC, as compared to that measured around the naked counterpart (i.e. the BI). When protected by in BC, both the generator and the proximal parts of the leads were completely free from fibrotic tissue. The insertion of an anti-adhesive, non-resorbable and well-tolerated BC interface between the implant and the surrounding tissue in the surgical pocket significantly reduced the formation of fibrotic tissue, ensuring an easy access to the device pocket, and thus creating the conditions for simplified CIED revision surgeries.
Up to one-third of patients referred for transcatheter tricuspid valve intervention (TTVI) have a transvalvular pacemaker (PPM) or implantable cardioverter-defibrillator (ICD) lead in place. Both the electrophysiology and interventional cardiology communities have been alerted to the complexity of decision-making in this situation due to potential interactions between the leads and the TTVI material, including the risk of jailing or damage to the leads. This document, commissioned by the European Heart Rhythm Association and the European Association of Percutaneous Cardiovascular Interventions of the ESC, reviews the scientific evidence to inform Heart Team discussions on the management of patients with a PPM or ICD who are scheduled for or have undergone TTVI.
1 November 2019 in Annals of Cardiothoracic Surgery
Aims: Treatment of patients with systemic cardiac implantable electronic device (CIED) infection with large lead vegetations is challenging and associated with relevant morbidity and mortality. To avoid complications from open surgical extraction, a novel approach with percutaneous aspiration of large vegetations prior to transvenous lead extraction was instituted. The results of this treatment concept were retrospectively analysed in this multicentre study. Methods and results: One hundred and one patients [mean age 68.2 ± 13.1 (30–92) years] were treated in four centres for endovascular CIED infection with large lead vegetations. Mean lead vegetation size was 30.7 ± 13.5 mm. Two hundred and forty-seven leads were targeted for extraction (170 pacemaker leads, 77 implantable cardioverter-defibrillator leads). Mean lead implant duration was 81.7 (1–254) months. The transcatheter aspiration system with a specialized long venous drainage cannula and a funnel-shaped tip was based on a veno-venous extracorporeal circuit with an in-line filter. The aspiration of vegetations showed complete procedural success in 94.0% (n = 95), partial success in 5.0% (n = 5). Three major complications (3.0%) were encountered. Complete procedural success (per lead) of the subsequently performed transvenous lead extraction procedure was 99.2% (n = 245). Thirty-day mortality was 3.0% (n = 3). Five patients (5.0%) died in the further course on Days 51, 54, 68, 134, and 182 post-procedure (septic complications: n = 4; heart failure: n = 1). Conclusion: The percutaneous aspiration procedure is highly effective and is associated with a low complication profile. The aspiration of vegetations immediately prior and during the lead extraction procedure may avoid septic embolization into the pulmonary circulation. This may potentially lead to a long-term survival benefit.