The CD/DVDs used as radon (222Rn) and thoron (220Rn) detectors can provide a sufficiently sensitive and cost-efficient option for passive radiation monitoring in underground mines. This note presents results of measurements made under real environmental conditions by CD/DVDs. Comparison with conventional diffusion chambers was made and good correspondence was observed. Correlation between 222Rn and 220Rn was studied by CD/DVDs and no signs for any correlation were observed. Dedicated study in a mine gallery showed that CD/DVDs can be successfully used for the purposes of ventilation diagnostics by identifying sources of air contaminated with radon.
A new generation of compact radon detectors with high sensitivity and fine spatial resolution (1–2 cm scale) was used to investigate indoor radon distribution and identify potential entry pathways. Solid-state nuclear track detectors (Kodak-Pathe LR-115 type II, Dosirad, France), combined with activated carbon fabric (ACC-5092-10), enabled sensitive, spatially resolved radon measurements. Two case studies were conducted: Case 1 involves a room with elevated radon levels suspected to originate from the floor. Case 2 involves a house with persistently high indoor radon concentrations despite active basement ventilation. In the first case, radon emission from the floor was found to be highly inhomogeneous, with concentrations varying by more than a factor of four. In the second, unexpectedly high radon levels were detected at electrical switches and outlets on walls in the living space, suggesting radon transport through wall voids and entry via non-hermetic electrical fittings. These novel detectors facilitate fine-scale mapping of indoor radon concentrations, revealing ingress routes that were previously undetectable. Their use can significantly enhance radon diagnostics and support the development of more effective mitigation strategies.
This study presents the results of a pilot survey utilizing an innovative DVD-based method to measure outdoor radon and thoron levels. Twenty-six discriminative radon/thoron detectors were deployed across four different territorial zones in Bulgaria. Positioned 1 m above the ground, these detectors were left in place for several months. Notably, the dataset reveals significant variability in measurements, even over short distances, with thoron exhibiting greater variability than radon. Radon levels ranged from 7 ± 1 to 34 ± 3 Bq m−3 (average: 21 Bq m−3), while thoron levels ranged from 13 ± 5 to 307 ± 54 Bq m−3 (average: 170 Bq m−3). A weak but statistically significant correlation (correlation coefficient: 0.559) was observed between radon and thoron levels, which improved significantly when averaged across the four zones. These findings underscore the importance of measuring both radon and thoron in outdoor surveys. High thoron levels can significantly bias radon measurements, particularly when radon concentrations are substantially lower than those of thoron. If further studies confirm the good correlation between area averages, the observed correlation between area-average values could be used to correct average radon levels in large areas (e.g., radon priority areas) for thoron interference when thoron data are missing from the analyzed radon dataset.