Hongkai Yang

Hongkai Yang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2025 in Current Medical Imaging
Verified
Journal Article
Open access
PDF file
WWWuling Wang
Wuling Wang
XQXuan Qi
Xuan Qi
YHYongsheng He
Yongsheng He
HYHongkai Yang
Hongkai Yang
DQDong Qi
Dong Qi
QCQiong Chen
Qiong Chen
Objective: The global incidence of lung cancer highlights the need for improved assessment of nodule characteristics to enhance early detection of lung adenocarcinoma presenting as ground-glass nodules (GGNs). This study investigated the applicability of radiomics features of vascular structures within GGNs for predicting invasiveness of GGNs. Methods: In total, 165 pathologically confirmed pulmonary GGNs were retrospectively analyzed. The nodules were classified into preinvasive and invasive groups and randomly categorized into training and validation sets in a 7:3 ratio. Four models were constructed and evaluated: radiomics-GGN, radiomics-vascular, clinical-radiomics-GGN, and clinical-radiomics-vascular. The predictive performance of these models was assessed using receiver operating characteristic curves, decision curve analysis, calibration curves, and DeLong’s test. Results: Significant differences and density were observed between the preinvasive and invasive groups in terms of age, nodule length, average diameter, morphology, lobulation sign (P = 0.006, 0.038, 0.046, 0.049, 0.002 and0.008 respectively). In the radiomics-GGN model, the support vector machine (SVM) approach outperformed logistic regression (LR), achieving an area under the curve (AUC) of 0.958 in the training set and 0.763 in the validation set. Similarly, in the radiomics-vascular model, the SVM approach outperformed LR. Furthermore, the clinical-radiomics-vascular model demonstrated superior predictive performance compared with the clinical-radiomics-GGN model, with an AUC of 0.918 in the training set and 0.864 in the validation set. DeLong’s test indicated significant differences in predicting the invasiveness of pulmonary nodules between the clinical-radiomics-vascular model and the clinical-radiomics-GGN model, both in the training and validation sets (P < 0.01). Conclusion: The radiomics models based on internal vascular structures of GGNs outperformed those based on GGNs alone, suggesting that incorporating vascular radiomics analysis can improve the noninvasive assessment of GGN invasiveness, thereby aiding in clinical decision-making and guiding biopsy selection and treatment planning.

18 February 2025 in Abdominal Radiology
Verified
Journal Article
Open access
PDF file
YHYongsheng He
Yongsheng He
XQXuan Qi
Xuan Qi
MZMin-Xiong Zhou
Min-Xiong Zhou
MLMengxiao Liu
Mengxiao Liu
HYHongkai Yang
Hongkai Yang
XYXu Yan
Xu Yan
Purpose: This study aims to compare the performance of mono-exponential (Mono), fractional-order-calculus (FROC), and multi-compartment (MC) diffusion models in differentiating prostate lesions, including benign prostatic hyperplasia (BPH) and prostate cancer (PCa), as well as classifying PCa by clinical significance and risk levels. Methods: \A prospective study was conducted with 224 men (aged 50–80) undergoing 3 T MR imaging. Regions of interest (ROIs) analyses were performed on quantitative parameters from Mono, FROC, and MC models. These parameters were evaluated for their ability to distinguish BPH from PCa, clinically significant (CS) from clinically insignificant (CInS) PCa, and among PCa risk levels. Group differences were assessed using the Mann–Whitney U test and Kruskal–Wallis test, followed by post-hoc Dunn’s test. ROC curves were plotted, and AUC was calculated. Logistic regression was used for parameter combinations, and performance was evaluated via 1000 bootstrap samples. The correlation between parameter pairs was analyzed. The image quality and PCa detection capability were also evaluated visually. Results: In distinguishing PCa from BPH, the F1, ADC, and D parameters from the three models achieved high AUCs of 0.92, 0.91, and 0.91, respectively. For differentiating CS-PCa from CInS-PCa, the F2 parameter and the combination of C1 + F2 from the MC model showed the highest AUCs (0.75 and 0.76). In assessing PCa risk levels, F2 and C1 + F2 from the MC model showed the highest AUCs (0.73 and 0.74) for low vs. intermediate-risk PCa. For intermediate vs. high-risk PCa, F1, F1F2, and β + F1F2 from MC and FROC models had the highest AUCs (0.66, 0.66, and 0.71). In addition, ADC was strongly or moderately correlated to D, μ, F1, F1F2, F3, C1 and C3, and not correlated to β and F2. ADC and C1 demonstrated high image quality and strong PCa detection capability. Conclusion: Advanced diffusion models, particularly the MC model, demonstrated a significant improvement over ADC in differentiating prostate lesions, especially between low and intermediate-risk PCa, between intermediate and high-risk PCa, and between clinically significant and insignificant PCa. Comparable performance was observed in distinguishing BPH from PCa among three models. Moreover, the combination of MC and FROC models further enhanced differentiation accuracy, particularly in the more challenging classifications between intermediate and high-risk PCa, where ADC alone proved inadequate. These results highlight the potential clinical value of MC model and combining MC and FROC models for more precise PCa risk stratification. Graphical