Just-in-time burn severity assessment plays a vital role in burn treatment and care. However, it is still difficult to quantitatively and promptly evaluate burn severity by existing medical imaging methods via initial burn depth measurement since burn wounds are usually dynamically developed. As an elastic skeleton of skin, the degree of conformational changes of collagen fibers caused by overheating can reflect the burn severity in a timelier manner. Herein, the polarized photoacoustic technique (PPAT) for just-in-time quantitative evaluation of burn severity via collagen fiber anisotropy assessment is proposed. First, phantom experiments demonstrate the ability of PPAT for deep imaging in a transport mean free path and accurately quantify changes in microstructural order by thermal damage. Then, the Pearson correlation coefficient of the PPAT in assessing burn severity is shown to be up to 0.95, validated by burn skin samples. The PPAT provides a just-in-time quantitative strategy for burn severity evaluation.
Polarization optical imaging can be used to characterize anisotropy in biological tissue microstructures and has been demonstrated to be a powerful tool for clinical diagnosis. However, the approach is limited by an inability to image targets deeper than due to strong optical scattering in biological tissues. As such, we propose a novel polarization microwave-induced thermoacoustic imaging (P-MTAI) technique to noninvasively detect variations in deep tissue by exploiting the thermoacoustic signals induced by four pulsed microwaves of varying polarization orientations. The proposed P-MTAI method overcomes the penetration limits of conventional polarization optical imaging and provides submillimeter resolution over depths of several centimeters. As part of the paper, the structural characteristics of tissues were quantified using a new parameter, the degree of microwave absorption anisotropy. P-MTAI was also applied to the noninvasive detection of morphological changes in cardiomyocytes as they transitioned from ordered to disordered states, providing a potential indication of myocardial infarction.
Reconstructing sparsely sampled data is fundamental for achieving high spatiotemporal resolution photoacoustic microscopy (PAM) of microvascular morphology in vivo. Convolutional networks (CNN) and generative adversarial networks (GAN) have been introduced to high-speed PAM, but due to the use of upsampling in CNN-based networks to restore details and the instability in GAN training, they struggle to learn the entangled microvascular network structure and vascular texture features, resulting in only achieving low detail-fidelity imaging of microvascular. The diffusion models is richly sampled and can generate high-quality images, which is very helpful for the complex vascular features in PAM. Here, we propose an approach named parallel diffusion models (PDM) with parallel learning of Noise task and Image task, where the Noise task optimizes through variational lower bounds to generate microvascular structures that are visually realistic, and the Image task improves the fidelity of the generated microvascular details through image-based loss. With only 1.56% of fully sampled pixels from photoacoustic human oral data, PDM achieves an LPIPS of 0.199. Additionally, using PDM in high-speed 16x PAM prevents breathing artifacts and image distortion issues caused by low-speed sampling, reduces the standard deviation of the Row-wise Self-Correlation Coefficient, and maintains high image quality. It achieves high confidence in reconstructing detailed information from sparsely sampled data and will promote the application of reconstructed sparsely sampled data in realizing high spatiotemporal resolution PAM.
Surgery represents the mainstream therapeutic modality in oncology. Aggressive radical surgery to achieve no residual tumor would improve survival, which is mainly affected by vascular involvement and accuracy of judging the negative margin of tumor resection. However, there is currently no intraoperative tool that can simultaneously perform microscopic analysis of the peritumoral vasculature in vivo and the surgical margin pathology of the tumor ex vivo, which leads to the randomness of one-time complete resection of the tumor, and the patient may have to undergo secondary surgery. To address this critical need, we developed a 532/266 nm dual-wavelength photoacoustic (PA) microscopy imaging (532/266-PAI) system that enables both in vivo tumor regional vascular involvement analysis and pathological margin assessment of fresh ex vivo tumor samples. A mammary tumor animal model was established to mimic the process of tumor resection, from in vivo imaging vascular involvement of tumor to intraoperative judgment of negative tumor margins. It is proved that the 532/266-PAI technology can identify the tumor vascular involvement through vascular visualization, determine the surgical plan, and then judge whether the tumor is completely removed through ultraviolet PA (UPA) tumor pathological imaging. Re-excision and secondary margin evaluation are performed when margin positive is diagnosed in the intraoperation UPA imaging. The 266/532-PAI technique has great potential for complete tumor resection in surgical navigation.
Anisotropic two-dimensional (2D) materials, such as black phosphorus (BP), normally possess unique directional in-plane electrical, optical, and thermal properties that are highly correlated with their crystalline orientations. Nondestructive visualization of their crystalline orientation is an indispensable premise for the 2D materials to harness their distinctive strengths in optoelectronic and thermoelectric applications. Here, by photoacoustically recording the anisotropic optical absorption variation under linearly polarized laser beams, an angle-resolved polarized photoacoustic microscopy (AnR-PPAM) is developed, capable of non-invasively determining and visualizing BP’s crystalline orientation. We theoretically deduced the physical relationship between the crystalline orientation and polarized photoacoustic (PA) signals, and experimentally proved the ability of AnR-PPAM to universally visualize BP’s crystalline orientation regardless of its thickness, substrate, and encapsulation layer. This method provides a new, to the best of our knowledge, strategy for crystalline orientation recognition of 2D materials with flexible measurement conditions, prefiguring important potential for the applications of anisotropic 2D materials.