Weijia Shao

Prof. Dr. Weijia Shao

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2024 in Optics Express
Verified
Journal Article
Closed access
HTHe Tian
He Tian
Ke TianKe Tian
Ke Tian
HZHaoyang Zhang
Haoyang Zhang
LSLaipeng Shao
Laipeng Shao
YWYongmei Wang
Yongmei Wang
JHJunhui Hu
Junhui Hu
A vector magnetic field sensor based on a ferrofluid-encapsulated coreless D-shaped fiber is proposed and demonstrated. The core of the singlemode fiber (SMF) is completely removed by fiber polishing technology, and the remaining part transformed into a multimode interference (MMI) waveguide. The exposed side-polishing plane enable the evanescent field to interact with surrounding magnetic fluid (MF). Relying on the non-circularly symmetric geometry of the coreless D-shaped fiber and the MF refractive index modulation by the orientation and intensity of the applied magnetic field, vector magnetic field sensing is achieved. The magnetic field response characteristics of the coreless D-shaped fibers with different residual thicknesses (RTs) are investigated. The experimental results show that a reduced RT yields enhanced sensitivity, and the magnetic field intensity sensitivity reaches -0.231 nm/mT and -0.483 dB/mT at a RT of 42.7 µm. The developed coreless D-shaped fiber sensor exclusively utilizes SMF, thereby offering a cost-effective scheme for the fabrication of vector magnetic field sensors.

10 February 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
QZQiunan Zhang
Qiunan Zhang
CCCan'ER Cheng
Can'ER Cheng
CHChuanyang Huang
Chuanyang Huang
XLXiangyu Liao
Xiangyu Liao
YWYongmei Wang
Yongmei Wang
JLJun Liu
Jun Liu
This study introduces a bilaterally polished D-shaped surface plasmon resonance sensor based on Au-TiO2 for early detection of cancer cells. The refractive indices of the six different types of normal and cancer cells detected ranged from 1.36 ~ 1.401. The finite element method is used for numerical analysis. The spectral interrogation method is used to detect the refractive index variations of cancer cells. According to numerical results, blood cancer has the highest wavelength sensitivity (23643 nm/RIU) in the structure of the optimal parameters. The wavelength sensitivities for the rest of the cancer cells are 10150 nm/RIU for skin cancer basal cells, 18291 nm/RIU for cervical cancer HeLa cells, 20642 nm/RIU for adrenal gland cancer PC 12 cells, 13142 nm/RIU for breast cancer type 1 MDA-MB-231 cells and 9142 nm/RIU breast cancer type 2 MCF-7 cells. Moreover, the FOM reaches a maximum of 382.28 /RIU with a maximum resolution of 4.23×10-6 RIU. Compared to related studies, the sensor design exhibits superior sensitivity, resolution, and figure of merit, making it highly beneficial for medical applications in cancer detection.

5 December 2024 in Physica Scripta
Verified
Journal Article
Closed access
CCCaner Cheng
Caner Cheng
CHChuanyang Huang
Chuanyang Huang
QZQiunan Zhang
Qiunan Zhang
XLXiangyu Liao
Xiangyu Liao
JYJun Yang
Jun Yang
YWYongmei Wang
Yongmei Wang
Sensors have been instrumental in driving technological progress and enhancing quality of life by delivering precise data and enabling intelligent responses across a multitude of disciplines. In alignment with the advancement of technology and the demands of both industrial production and everyday life, a dual-core PCF-SPR sensor was developed. The sensor, based on D-type photonic crystal fiber and incorporating ITO and Au, was designed for the simultaneous detection of refractive index and temperature. Research results demonstrate that by using the finite element method, the maximum sensitivity of the structure in the refractive index detection range of 1.33–1.39 reached 18,100 nm RIU−1, and the maximum sensitivity in the temperature detection range of 10 °C-50 °C reached −12.3 nm °C−1. The refractive index and temperature detection channels operate independently of each other. This sensor architecture enables simultaneous dual-parameter measurement of refractive index and temperature, is lightweight and highly sensitive, and possesses potential applications in cancer cell detection and tsunami prevention.

24 July 2025 in Physica Scripta
Verified
Journal Article
Closed access
QZQiunan Zhang
Qiunan Zhang
XLXiangyu Liao
Xiangyu Liao
YWYongmei Wang
Yongmei Wang
CCCaner Cheng
Caner Cheng
CHChuanyang Huang
Chuanyang Huang
JLJun Liu
Jun Liu
The sensor proposed in the present study is a novel bilateral polished D-type photonic crystal fiber (PCF)-based dual-parameter device that operates on the principle of surface plasmon resonance (SPR). It was designed for the simultaneous detection of six types of cancer—skin cancer, cervical cancer, blood cancer, adrenal gland cancer, and two subtypes of breast cancer (type 1 and type 2)—alongside temperature measurement. Numerical simulations employing the full-vector finite element method indicate that, within the refractive index (RI) range of 1.360 – 1.401, the sensor achieved a maximum wavelength sensitivity of 32,000 nm RIU−1 for breast cancer type 2 detection, with a high figure of merit (FOM) of 914 RIU−1 and a detection resolution of 3.125 × 10−6 RIU. Further, the sensor exhibited an ultrahigh temperature sensitivity of −28.7 nm °C−1 within the 0 °C–50 °C range, accompanied by a FOM of −0.164 °C−1 and a resolution of 3.484 × 10−3 °C. Compared to similar designs, the proposed sensor enfs independent and highly sensitive detection of both refractive index and temperature, while featuring a simplified structure and low fabrication complexity. These characteristics underscore its strong potential for application in biomedical diagnostics, particularly for cancer detection and monitoring.

29 June 2022 in Optics Express
Verified
Journal Article
Closed access
WSWeijia Shao
Weijia Shao
JHJunhui Hu
Junhui Hu
YWYongmei Wang
Yongmei Wang
Cost-effective and high-responsivity photodetectors at a telecommunication wavelength of 1550 nm are highly desired in optical communication systems. Differing from conventional semiconductor-based photodetectors, several planar hot-electron photodetectors (HE PDs) that operate at 1550 nm have been reported. However, these devices were often comprised of many planar layers and exhibited relatively low responsivities. Herein, we propose a design of high-performance planar HE PDs consisting of five layers. Utilizing Fabry-Pérot (FP) resonance, the nearly perfect absorption of the proposed device can be achieved at the targeted wavelength of 1550 nm. Simulation results show that FP resonance orders are crucial for the optical absorption efficiencies, and then electrical responses. Analytical electrical calculations reveal that, benefiting from the strong absorption (>0.6) in the ultrathin Au layer with a thickness of 5 nm and the low Schottky barrier (0.5 eV) of Au-MoS2 contact, predicted responsivity of proposed HE PD at zero-order FP resonance is up to ∼10 mA/W. Our design provides a new approach to realize low-cost and efficient photodetection for optical communication technology.

15 April 2024 in Nanotechnology
Verified
Journal Article
Closed access
WSWeijia Shao
Weijia Shao
WCWeihao Cui
Weihao Cui
YXYixiao Xin
Yixiao Xin
JHJunhui Hu
Junhui Hu
XLXiaofeng Li
Xiaofeng Li
Although outstanding detectivities, InGaAs photodetectors for optic fiber communication are often costly due to the need for cooling. Therefore, cryogen-free and cost-effective alternatives working in telecommunication bands are highly desired. Here, we present a design of hot-electron photodetectors (HE PDs) with attributes of room-temperature operation and strong optical absorption over S and C bands (from 1460 to 1565 nm). The designed HE PD consists of a metal–semiconductor–metal hot-electron stack integrated with a front grating. Optical simulations reveal that mode hybridizations between Fabry–Pérot resonance and grating-induced surface plasmon excitation lead to high absorption efficiencies (≥0.9) covering S and C bands. Probability-based electrical calculations clarify that device responsivity is mainly determined by working wavelength on the premise of broadband strong absorption. Moreover, through comparison studies between the grating-assisted HE PD and purely planar microcavity system that serves as a reference, we highlight the design superiorities in average absorption and average responsivity with optimized values of 0.97 and 0.73 mA W−1, respectively. The upgraded peformances of the designed device are promising for efficient photoelectric conversion in optic fiber communication systems.