Goal: To develop bending angle sensors based on double-layer capacitance for monitoring joint angles during cycling exercises. Methods: We develop a bending angle sensor based on double-layer capacitive and conducted three stretching, bending, and cycling tests to evaluate its validity. Results: We demonstrate that the bending angle sensor based on double-layer capacitance minimizes the change in the capacitance difference in the stretching test. The hysteresis and root mean square error (RMSE) compared with the optical motion capture show hysteresis: 8.0% RMSE and 3.1° in the bending test. Moreover, a cycling experiment for human joint angle measurements confirm the changes in accuracy. The RMSEs ranged from 4.7° to 7.0°, even when a human wears leggings fixed with the developed bending-angle sensor in the cycling test. Conclusion: The developed bending angle sensor provides a practical application of the quantitative and observational evaluation tool for knee joint angles.
In this study, we focused on the relationship between mental stress and gastric motility and have tried to develop a measurement system of human gastric motility for the quantification of mental stress. A mental stress measurement system should be used easily in daily life. However, general measurement system as electrogastrography, endoscopy, CT, ultrasonic echogram isn't suitable for the home use. Then, we have developed non-invasive and compact measurement system of gastric motility using near-infrared (NIR) light. This system consists of NIR LEDs and an avalanche photodiode (APD). APD receives the NIR light transmitting outside the body from NIR LEDs and reflecting on the gastric wall. In the experiment, an ultrasonic echogram was used simultaneously to confirm our new method. The result showed that the waveform got by our method coincides with the cycle of contractile activity of stomach, and it was proved that our measurement system using NIR light could measure gastric motility. In addition, we performed chronic mental stress measurement intended for students to examine relationship between chronic mental stress and gastric motility. Experimental period was from two weeks before graduation examination to two weeks after graduation examination. The result showed that chronic mental stress may invoke gastric dysrhythmia, and chronic mental stress could be evaluated by long term monitoring of gastric motility using our NIR measurement system
1 January 2005 in The Proceedings of the JSME Conference on Frontiers in Bioengineering
In this study, we focused on the relationship between mental stress and gastric motility and have tried to develop a measurement system of human gastric motility for the quantification of mental stress. A mental stress measurement system should be used easily in daily life. However, general measurement system as electrogastrography, endoscopy, CT, ultrasonic echogram isn't suitable for the home use. Then, we have developed non-invasive and compact measurement system of gastric motility using near-infrared (NIR) light. This system consists of NIR LEDs and an avalanche photodiode (APD). APD receives the NIR light transmitting outside the body from NIR LEDs and reflecting on the gastric wall. In the experiment, an ultrasonic echogram was used simultaneously to confirm our new method. The result showed that the waveform got by our method coincides with the cycle of contractile activity of stomach, and it was proved that our measurement system using NIR light could measure gastric motility. In addition, we performed chronic mental stress measurement intended for students to examine relationship between chronic mental stress and gastric motility. Experimental period was from two weeks before graduation examination to two weeks after graduation examination. The result showed that chronic mental stress may invoke gastric dysrhythmia, and chronic mental stress could be evaluated by long term monitoring of gastric motility using our NIR measurement system