George Naveen Thomas

Dr. George Naveen Thomas

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2012 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
Carol Y. L. CheungCarol Y. L. Cheung
Carol Y. L. Cheung
GTGeorge Naveen Thomas
George Naveen Thomas
WTWanting Tay
Wanting Tay
MIM. Kamran Ikram
M. Kamran Ikram
WHWynne Hsu
Wynne Hsu
TWTien Yin Wong
Tien Yin Wong

2 December 2016 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
SYStephanie M Young
Stephanie M Young
GSGangadhara Sundar
Gangadhara Sundar
TLThiam-Chye Lim
Thiam-Chye Lim
SLStephanie S Lang
Stephanie S Lang
GTGeorge Naveen Thomas
George Naveen Thomas
SAShantha Amrith
Shantha Amrith
Purpose Bioresorbable implants offer several advantages over permanent implants and serve as a useful alternative in the reconstruction of orbital fractures. Our aim of the study was to evaluate the clinical effectiveness and safety of various bioresorbable implants in the repair of orbital fractures. Methods A retrospective review of all patients who had undergone orbital fracture repair with bioresorbable implants in a single tertiary trauma centre from January 2005 to December 2014 was performed. Main outcome measures included improvement in ocular motility, diplopia, enophthalmos and infraorbital hypoaesthesia, as well as complication rates. Results Our study comprised 94 patients and 98 orbits. The types of fractures included orbital floor blow-out fractures (56.1%), zygomaticomaxillary complex fractures (20.4%), combined orbital floor and medial wall fractures (15.3%) and medial wall blow-out fractures (5.1%). The implants evaluated included poly-L/DL-lactide implants (P[L/DL]LA) 85/15 (Rapidsorb), (P[L/DL]LA) 70/30 (PolyMax), polycaprolactone (Osteomesh) and (P[L/DL]LA) 70/30 (MacroPore). There was significant improvement in ocular motility, diplopia, enophthalmos and infraorbital hypoaesthesia postoperatively at week 1, 1 month and 6 months (p<0.001). Comparison of results between the various implants and types of fractures showed no significant difference in postoperative outcome and complications. Late postoperative imaging at 15–24 months showed complete resorption of implants and features of neobone formation in all patients. Conclusion Our experience with bioresorbable implants shows them to be safe and clinically effective in the reconstruction of orbital fractures.

8 November 2016 in Orbit
Verified
Journal Article
Closed access
GTGeorge Naveen Thomas
George Naveen Thomas
JCJ. Chan
J. Chan
GSG. Sundar
G. Sundar
SAS. Amrith
S. Amrith
Both the Müller muscle-conjunctiva resection (MMCR) and levator advancement (LA) procedures can be used to manage ptosis in patients with good levator function. The aim of this article is to evaluate the efficacy and cosmetic outcomes of the two procedures. The clinical records of 29 consecutive eyelids of 26 patients undergoing MMCR and 30 eyelids of 23 patients undergoing LA were analysed. Eleven (42%) in the LA group and 9 (39%) in the MMCR group were male. The preoperative eyelid measurements were significantly different in the LA compared to the MMCR groups, in terms of palpebral aperture (PA) (6.3 vs 7.4, p = 0.01), marginal reflex distance 1 (MRD1) (-0.1 vs 1.5, p < 0.001) and levator function (LF) (12.1 vs 13.4, p = 0.03). The MRD1 1 month post-surgery was slightly less in the LA group compared to the MMCR group (2.6 vs 3.18 mm, p = 0.047) but not significantly different at months 3 and 6. The final change in MRD1 was significantly higher in the LA group (2.93 vs 1.76, p = 0.004). The MMCR group had a lower incidence of lid contour abnormalities (0% vs 20%, p = 0.01) and overcorrection (0% vs 13%, p = 0.04). There was no statistically significant difference in the rates of undercorrection in either group. Both the MMCR as well as LA procedures are effective for mild to moderate ptosis in patients with good levator function. Patients undergoing MMCR had higher success rates, better preservation of the natural lid contour, and a lower incidence of overcorrection than patients undergoing LA.

1 April 2014 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
GTGeorge Naveen Thomas
George Naveen Thomas
SOShin-Yeu Ong
Shin-Yeu Ong
YTYih Chung Tham
Yih Chung Tham
WHWynne Hsu
Wynne Hsu
MLMong Li Lee
Mong Li Lee
Carol Y. L. CheungCarol Y. L. Cheung
Carol Y. L. Cheung
Purpose. Macular diseases may be associated with an altered retinal vasculature. We describe and test new software for the measurement of retinal vascular fractal dimension to quantify the complexity of retinal vasculature at the macula (Dmac) and to compare this with fractal dimension measured around the optic disc (Ddisc). Methods. A total of 342 macular-centered and optic disc-centered digital retinal photographs from 171 subjects was selected randomly from a population-based study. Retinal vascular fractional dimension (Df) was measured by two trained graders using a computer-assisted program (SIVA-FA, software version 1.0, National University of Singapore) on macula-centered (Dmac) and optic disc-centered (Ddisc) photographs, to assess intergrader reliability. Measurements were repeated after two weeks to determine intragrader reliability. A separate 50 pairs of consecutively repeated images were selected and measured using SIVA-FA to assess intrasession reliability. Reliability analyses were conducted using intraclass correlation coefficients (ICC), and multiple linear regression analyses were performed to compare factors associated with Dmac and Ddisc measurements. Results. The mean (SD) Dmac and Ddisc values were 1.453 (0.060) and 1.484 (0.043), respectively, and were highly correlated (r = 0.70, P < 0.001). Intragrader, intergrader, and intrasession reliability for both Df measures was high (ICCs ranging from 0.88–0.99). In multiple regression analyses, age (both β = −0.03, P < 0.001) and hypertension (β = −0.02, P = 0.011; β = −0.02, P = 0.021, respectively) were independently associated with Dmac and Ddisc. Conclusions. The complexity of the retinal vasculature in the macula can be measured reliably and may be a useful tool to study parafoveal vascular networks in macula diseases, such as diabetic maculopathy.

3 July 2012 in Journal of Cardiovascular Translational Research
Verified
Journal Article
Open access
PDF file
HCHelen H. L. Chan
Helen H. L. Chan
ZHZaal Meher Homji
Zaal Meher Homji
RGRenata SM Gomes
Renata SM Gomes
DSDominic Sweeney
Dominic Sweeney
GTGeorge Naveen Thomas
George Naveen Thomas
Carolyn CarrCarolyn Carr
Carolyn Carr
To investigate the effects of age and disease on endogenous cardiac progenitor cells, we obtained right atrial and left ventricular epicardial biopsies from patients (n = 22) with chronic ischaemic heart disease and measured doubling time and surface marker expression in explant- and cardiosphere-derived cells (EDCs, CDCs). EDCs could be expanded from all atrial biopsy samples, but sufficient cells for cardiosphere culture were obtained from only 8 of 22 ventricular biopsies. EDCs from both atrium and ventricle contained a higher proportion of c-kit+ cells than CDCs, which contained few such cells. There was wide variation in expression of CD90 (atrial CDCs 5–92 % CD90+; ventricular CDCs 11–89 % CD90+), with atrial CDCs cultured from diabetic patients (n = 4) containing 1.6-fold more CD90+ cells than those from non-diabetic patients (n = 18). No effect of age or other co-morbidities was detected. Thus, CDCs from atrial biopsies may vary in their therapeutic potential.

3 October 2024 in Cancers
Verified
Journal Article
Open access
PDF file
GTGeorge Naveen Thomas
George Naveen Thomas
I-Ling ChouI-Ling Chou
I-Ling Chou
LGLingam Gopal
Lingam Gopal
Plaque radiotherapy is an effective treatment modality for medium-sized ocular tumors such as uveal melanoma. The authors review the available literature and concisely summarize the current state of the art of ophthalmic plaque brachytherapy. The choice of radioisotope, which includes Ruthenium-106 and Iodine-125, depends on the intended treatment duration, tumor characteristics, and side effect profiles. Ophthalmic plaques may be customized to allow for the delivery of a precise radiation dose by adjusting seed placement and plaque shape to minimize collateral tissue radiation. High dose rate (HDR) brachytherapy, using beta (e.g., Yttrium-90) and photon-emitting sources (e.g., Ytterbium-169, Selenium-75), allows for rapid radiation dose delivery, which typically lasts minutes, compared to multiple days with low-dose plaque brachytherapy. The efficacy of Ruthenium-106 brachytherapy for uveal melanoma varies widely, with reported local control rates between 59.0% and 98.0%. Factors influencing outcomes include tumor size, thickness, anatomical location, and radiation dose at the tumor apex, with larger and thicker tumors potentially exhibiting poorer response and a higher rate of complications. Plaque brachytherapy is effective for selected tumors, particularly uveal melanoma, providing comparable survival rates to enucleation for medium-sized tumors. The complications of plaque brachytherapy are well described, and many of these are treatable.