XU GUO

Mr. XU GUO


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
YCYuzhe Chen
Yuzhe Chen
Feng WuFeng Wu
Feng Wu
LSLinjun Shi
Linjun Shi
YLYang Li
Yang Li
PQPeng Qi
Peng Qi
XGXU GUO
XU GUO
To reduce errors in sub-synchronous oscillation (SSO) modal identification and improve the accuracy and noise resistance of the traditional Prony algorithm, this paper focuses on SSOs caused by the integration of doubly fed induction generators (DFIGs) with series compensation into the grid. A novel SSO modal identification method based on the hippopotamus optimization–variational mode decomposition (HO-VMD) and singular value decomposition–regularized total least squares–Prony (SVD-RTLS-Prony) algorithms is proposed. First, the energy ratio function is used for real-time monitoring of the system to identify oscillation signals. Then, to address the limitations of the VMD algorithm, the HO algorithm’s excellent optimization capabilities were utilized to improve the VMD algorithm, leading to preliminary denoising. Finally, the SVD-RTLS-improved Prony algorithm was employed to further suppress noise interference and extract oscillation characteristics, allowing for the accurate identification of SSO modes. The performance of the proposed method was evaluated using theoretical and practical models on the Matlab and PSCAD simulation platforms. The results indicate that the algorithms effectively perform denoising and accurately identify the characteristics of SSO signals, confirming its effectiveness, accuracy, superiority, and robustness against interference.

9 October 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
YCYuzhe Chen
Yuzhe Chen
Feng WuFeng Wu
Feng Wu
LSLinjun Shi
Linjun Shi
YLYang Li
Yang Li
XGXU GUO
XU GUO
PQPeng Qi
Peng Qi
The doubly fed variable speed pumped storage (DFVSPS) system is a hydraulically, mechanically, and electrically coupled system, and the characteristics of the components from the water conveyance system to the transmission line need to be fully considered in the oscillation analysis. Hence, the model of the water conveyance system is included to investigate the oscillation characteristics of the DFVSPS connecting to the grid via a series-compensated line. A small-signal state-space model of the DFVSPS system in the generation mode is first established. The oscillation characteristics of the DFVSPS are studied, and the dominant state variables for each oscillation mode are identified. The impact of system parameters on oscillations is further studied, and simulations are carried out to validate the accuracy of the model. The results indicate the oscillation mode of the DFVSPS comprises the electrical sub-synchronous oscillation (SSO) mode and the hydraulically, mechanically coupled low-frequency mechanical oscillation modes. When the series compensation level is high, the SSO becomes divergent, and the system is more likely to be unstable. Optimizing the rotor-side control parameters and the governor control parameters, sub-synchronous and low-frequency oscillations could be effectively suppressed, respectively. This study provides reference suggestions for the development and use of the future DFVSPS system.

8 September 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
XGXU GUO
XU GUO
YLYang Li
Yang Li
Feng WuFeng Wu
Feng Wu
LSLinjun Shi
Linjun Shi
YCYuzhe Chen
Yuzhe Chen
HWHailun Wang
Hailun Wang
With the continuous development of renewable energy worldwide, the issue of frequency stability in power systems has become increasingly serious. Enhancing the inertia level of power systems by configuring battery storage to provide virtual inertia has garnered significant research attention in academia. However, addressing the non-linear characteristics of frequency stability constraints, which complicate model solving, and managing the uncertainties associated with renewable energy and load, are the main challenges in planning energy storage for high-proportion renewable power systems. In this context, this paper proposes a battery storage configuration model for high-proportion renewable power systems that considers minimum inertia requirements and the uncertainties of wind and solar power. First, frequency stability constraints are transformed into minimum inertia constraints, primarily considering the rate of change of frequency (ROCOF) and nadir frequency (NF) indicators during the transformation process. Second, using historical wind and solar data, a time-series probability scenario set is constructed through clustering methods to model the uncertainties of wind and solar power. A stochastic optimization method is then adopted to establish a mixed-integer linear programming (MILP) model for the battery storage configuration of high-proportion renewable power systems, considering minimum inertia requirements and wind-solar uncertainties. Finally, through a modified IEEE-39 bus system, it was verified that the proposed method is more economical in addressing frequency stability issues in power systems with a high proportion of renewable energy compared to traditional scheduling methods.