Sleep monitoring in an unattended home setting provides important information complementing and extending the clinical polysomnography findings. The validity of a wearable textile electrocardiography (ECG)-belt has been proven in a clinical setting. For evaluation in a home setting, ECG signals and features were acquired from 12 patients (10 males and 2 females, showing an interquartile range for age of 48–59 years and for body mass indexes (BMIs) of 28.0–35.5) over 28 nights. The signal quality was assessed by artefacts detection, signal-to-noise ratio, and Poincaré plots. To assess the validity, the data were compared to previously reported data from the clinical setting. It was found that the artefact percentage was slightly reduced for the ECG-belt from 9.7% ± 14.7% in the clinical setting, to 7.5% ± 10.8% in the home setting. The signal-to-noise ratio was improved in the home setting and reached similar values to the gel electrodes in the clinical setting. Finally, it was found that for artefact percentages above 3%, Poincaré plots are instrumental to evaluate the origin of artefacts. In conclusion, the application of the ECG-belt in a home setting did not result in a reduction in signal quality compared to the ECG-belt used in the clinical setting, and thus provides new opportunities for patient pre-screening or follow-up.

28 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
PFPiero Fontana
Piero Fontana
NMNeusa R. Adão Martins
Neusa R. Adão Martins
MCMartin Camenzind
Martin Camenzind
René RossiRené Rossi
René Rossi
Florent BatyFlorent Baty
Florent Baty
SASimon Annaheim
Simon Annaheim
Even for 1-lead electrocardiography (ECG), single-use gel conductive electrodes are employed in a clinical setting. However, gel electrodes show limited applicability for long-term monitoring due to skin irritation and detachment. In the present study, we investigated the validity of a textile ECG-belt suitable for long-term measurements in clinical use. In order to assess the signal quality and validity of the ECG-belt during sleep, 242 patients (186 males and 56 females, age 52 (interquartile range 42–60) years, body mass index 29 (interquartile range 26–33) kg·m−2) with suspected sleep apnoea underwent overnight polysomnography including standard 1-lead ECG recording. The single intervals between R-peaks (RR-intervals) were calculated from the ECG-signals. We found a mean difference for average RR-intervals of −2.9 ms, a standard error of estimate of 0.39%, as well as a Pearson r of 0.91. Furthermore, we found that the validity of the ECG-belt decreases when lying on the side, which was potentially due to the fitting of the belt. In conclusion, the validity of RR-interval measurements using the ECG-belt is high and it may be further improved for future applications by optimizing wear fitting.

26 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Florent BatyFlorent Baty
Florent Baty
DCDragan Cvetkovic
Dragan Cvetkovic
MBMaximilian Boesch
Maximilian Boesch
FBFrederik Bauer
Frederik Bauer
NMNeusa R. Adão Martins
Neusa R. Adão Martins
MBMartin Brutsche
Martin Brutsche
Sleep apnea (SA) is a prevalent disorder characterized by recurrent events of nocturnal apnea. Polysomnography (PSG) represents the gold standard for SA diagnosis. This laboratory-based procedure is complex and costly, and less cumbersome wearable devices have been proposed for SA detection and monitoring. A novel textile multi-sensor monitoring belt recording electrocardiogram (ECG) and breathing frequency (BF) measured by thorax excursion was developed and tested in a sleep laboratory for validation purposes. The aim of the current study was to evaluate the diagnostic performance of ECG-derived heart rate variability and BF-derived breathing rate variability and their combination for the detection of sleep apnea in a population of patients with a suspicion of SA. Fifty-one patients with a suspicion of SA were recruited in the sleep laboratory of the Cantonal Hospital St. Gallen. Patients were equipped with the monitoring belt and underwent a single overnight laboratory-based PSG. In addition, some patients further tested the monitoring belt at home. The ECG and BF signals from the belt were compared to PSG signals using the Bland-Altman methodology. Heart rate and breathing rate variability analyses were performed. Features derived from these analyses were used to build a support vector machine (SVM) classifier for the prediction of SA severity. Model performance was assessed using receiver operating characteristics (ROC) curves. Patients included 35 males and 16 females with a median age of 49 years (range: 21 to 65) and a median apnea-hypopnea index (AHI) of 33 (IQR: 16 to 58). Belt-derived data provided ECG and BF signals with a low bias and in good agreement with PSG-derived signals. The combined ECG and BF signals improved the classification accuracy for SA (area under the ROC curve: 0.98; sensitivity and specificity greater than 90%) compared to single parameter classification based on either ECG or BF alone. This novel wearable device combining ECG and BF provided accurate signals in good agreement with the gold standard PSG. Due to its unobtrusive nature, it is potentially interesting for multi-night assessments and home-based patient follow-up.