Exoskeleton robots found application in neurorehabilitation, telemanipulation, and power augmentation. The human–robot attachment system of an exoskeleton should transmit all the interaction forces while keeping the anatomical and robotic joint axes aligned. Existing attachment concepts were bounding the performance of modern exoskeletons due to insufficient stiffness for high-performance force control, time-consuming adaption processes, and/or bulkiness. Therefore, we developed an augmented attachment system for a recent fully actuated nine-degree-of-freedom upper limb exoskeleton. The proposed system was compared to a conventional solution in a case study with four participants. The proposed attachment system lowered the relative motion between the human and the robot under static loads for all defined landmarks by 45% on average. The occurrence of undesired contacts in the trials was mitigated by 74%, thus improving conditions for closed-loop force control. Furthermore, the proposed system adapted better to the user's anatomy facilitating more accurate alignment and less obstruction. On average, self-attachment took $\mathbf {43(8.3)}$$\mathrm{s}$ to don(doff). Thereby, the alignment of anatomic landmarks had typically less than 15 mm offset to a thorough expert alignment, making self-attachment eligible. The augmented attachment system and the insights gained by the case study are expected to enable improvement of the physical human–robot interaction of exoskeletons.
Robots were introduced in the field of upper limb neurorehabilitation to relieve the therapist from physical labor, and to provide high-intensity therapy to the patient. A variety of control methods were developed that incorporate patients' physiological and biomechanical states to adapt the provided assistance automatically. Higher level states, such as selected type of assistance, chosen task characteristics, defined session goals, and given patient impairments, are often neglected or modeled into tight requirements, low-dimensional study designs, and narrow inclusion criteria so that presented solutions cannot be transferred to other tasks, robotic devices or target groups. In this work, we present the design of a modular high-level control framework based on invariant states covering all decision layers in therapy. We verified the functionality of our framework on the assistance and task layer by outlaying the invariant states based on the characteristics of 20 examined state-of-the-art controllers. Then, we integrated four controllers on each layer and designed two algorithms that automatically selected suitable controllers. The framework was deployed on an arm rehabilitation robot and tested on one participant acting as a patient. We observed plausible system reactions to external changes by a second operator representing a therapist. We believe that this work will boost the development of novel controllers and selection algorithms in cooperative decision-making on layers other than assistance, and eases transferability and integration of existing solutions on lower layers into arbitrary robotic systems.
Exoskeletons operate in continuous haptic interaction with a human limb. Thus, this interaction is a key factor to consider during the development of hardware and control policies for these devices. Physics simulations can complement real-world experiments for prototype validation, leading to higher efficiency in hardware and software development iterations as well as increased safety for participants and robot hardware. Here, we present a simulation framework of the full rigid-body dynamics of a coupled human and exoskeleton arm built to validate the full software stack. We present a method to model the human-robot interaction dynamics as decoupled spring-damper systems based on anthropometric data. Further, we demonstrate the application of the simulation framework to predict the closed-loop haptic-rendering performance of a 9-DOF exoskeleton in interaction with a human. The simulation was capable of simulating the closed-loop system’s reaction to an impact on a haptic wall. The intrusion into the compliant walls was predicted with a relative accuracy of 6% to 13%. Admissible control gains could be predicted with an accuracy of around 14%, and higher prediction accuracy is indicated when modeling the torque tracking bandwidth of the actuators. Hence, the simulation is valuable for validating prototype software, developing intuition, and a better understanding of the complex characteristics of the coupled system dynamics, even though the quantitative prediction is limited.
Currently, therapists struggle with interaction of rehabilitation robots due to non-intuitive interfaces. Therefore their acceptance of these robots are limited. This paper presents the development of ARMStick, a lightweight and small robotic interface in the shape of a human arm with 4 actuated and 3 unactuated joints, to facilitate the interaction between therapists and rehabilitation robots. It allows therapists to intuitively perceive joint-dependent data as recorded by rehabilitation robots, and teach poses and trajectories to individualize therapy to the patient. It’s range of motion (RoM) covers the RoM of a healthy human. The device’s measuring accuracy of CI 95% $ \lt \pm 0.322^{\circ}$ and movement accuracy of CI 70% $ \lt \pm 5.23^{\circ}$ lie within the confidence interval of average visual perception. A demonstration of the device to 5 therapists indicated that it could indeed improve efficiency and efficacy bottlenecks in current robot-assisted therapy. Comparison of ARMStick to two visual user interfaces showed a decrease in mean adaptation time from 15s to 5s for three arm configurations presented to the therapists.
Upper-limb spasticity, frequent after central nervous system lesions, is typically treated with botulinum neurotoxin type A (BoNT-A) injections to reduce muscle tone and increase range of motion. However, performing adjunct physical therapy post-BoNT-A can be challenging due to residual weakness or spasticity. This study evaluates the feasibility of hand therapy using a robotic hand orthosis (RELab tenoexo) with a mobile phone application as an adjunct to BoNT-A injections. Five chronic spastic patients participated in a two-session pilot study. Functional (Box and Block Test (BBT), Action Research Arm Test (ARAT)), and muscle tone (Modified Ashworth Scale (MAS)) assessments were conducted to assess functional abilities and impairment, along with usability evaluations. In the first session, subjects received BoNT-A injections, and then they performed a simulated unsupervised therapy session with the RELab tenoexo in a second session a month later. Results showed that BoNT-A reduced muscle tone (from 12.2 to 7.4 MAS points). The addition of RELab tenoexo therapy was safe, led to functional improvements in four subjects (two-cube increase in BBT as well as 2.8 points in grasp and 1.3 points in grip on ARAT). Usability results indicate that, with minor improvements, adjunct RELab tenoexo therapy could enhance therapy doses and, potentially, long-term outcomes.