The bipolar short circuit fault, which is the most destructive DC side fault of MMC-HVDC systems, and its riding through strategy is a current hotspot. Hybrid MMC is a promising topology for HVDC applications with the capability of DC fault isolation, however, it still suffers from the high cost. This paper proposes a mechanical DC breakers and hybrid MMC based coordinated DC fault ride-through strategy that can reduce the ratio of the full-bridge submodules (FBSMs) in the hybrid MMC and obviously cut the cost. To be specific, this strategy mainly depends on the FBSM’s negative output to suppress the fault current and eventually block it with the mechanical DC breakers. The impact on the performance of fault ride-through by the ratio of FBSMs in the hybrid MMC is analyzed, and the superiority of the strategy proposed in this paper has been proved with the analysis of conventional strategies. Finally, the effectiveness of the proposed strategy is validated with the RT-LAB experimental platform, and the optimal ratio range is obtained through the multiple groups of simulation experiments with different ratios of FBSMs in hybrid MMC base on MATLAB/Simulink.
As the share of renewable energy in a grid increases, the grid’s frequency support capability weakens, and the spatial distribution of grid frequency becomes more pronounced. As a result, control strategies based on system frequency consistency and traditional frequency regulation dominated by synchronous machines are becoming increasingly inadequate for meeting the frequency regulation requirements of new-type power systems. To enhance the system’s frequency support capability, it is imperative to fully utilize the frequency regulation resources within the power system. To address this issue, this paper first introduces a system frequency security posture assessment method that accounts for the spatial distribution characteristics of the grid. Subsequently, a parameter optimization method for diverse frequency regulation resources is proposed in conjunction with the proposed comprehensive evaluation method for frequency regulation. Next, using a renewable energy feeder regional grid as an example, an integrated frequency regulation method based on the system frequency security posture is presented. Finally, the frequency regulation performance and economic costs of different frequency regulation methods are analyzed under various operating scenarios and disturbances using a model based on actual data from the renewable energy feeder regional grid. The simulation and index calculation results demonstrate that the method proposed in this paper effectively enhances the system’s frequency support capability, reduces the frequency disparity between different nodes within the grid, and maintains high economic performance.