High-precision tracking and localization of the end of industrial robots is one of the most important technologies to realize high efficiency, high precision, and high safety of robots. Indoor global positioning system (iGPS), as a widely used indoor measurement system, has many advantages that cannot be replaced by other measurement devices, such as high scalability, simultaneous measurement of multiple targets, etc. However, due to the unique measurement principle of iGPS, it does not have good dynamic measurement performance. In order to enhance the dynamic measurement performance of iGPS and maximize its advantages, this paper proposes a correction algorithm that can effectively improve the dynamic measurement accuracy of iGPS based on the ideas of ‘transforming motion into static’ and ‘equivalent substitution’ after in-depth research on the measurement principle of iGPS. To verify the correctness of the mathematical principle of the algorithm and the value of engineering application, this paper has carried out a MATLAB simulation test and real measurement test. The experimental results show that the proposed correction algorithm can effectively improve the dynamic measurement accuracy of iGPS, and the correction algorithm can reduce the global error of the measurement results to within 0.1 mm in any robot trajectory and reasonable speed range, which is in line with the general requirements of industrial measurement.
As a result of the ongoing upgrading of the manufacturing industries, higher and higher requirements are being proposed for assembly precision. In particular, in the industries that involve assembly of large-sized products, it is hoped that assembly accuracy can still be guaranteed as the product size increases. The emergence of the indoor Global Positioning System (iGPS) will enable this demand to be met. In this work, we have conducted in-depth research on the measurement principles and the dynamic measurement performance of the iGPS measurement system. In addition, based on the motion equation for the tracked target, an analytical method to calculate the compensation amount required for dynamic measurements is proposed. This method is suitable for accurate measurement of the actual trajectory of a target in real time when the theoretical trajectory of this tracked target is known. We set up a simulation environment in MATLAB and tested the proposed method. The simulation testing proved that the method can compensate effectively for errors in iGPS dynamic measurement.
Hand to eye calibration is one of the most important steps to realize high flexibility and digitization of industry. In this paper, base on the research background of improving the degree of automation and flexibility in the field of aircraft fuselage inspection and detection, the hand to eye calibration under large size of operating volume is firstly studied based on indoor global positioning system (iGPS). A new calibration mathematical model A i x = Yb i is firstly proposed under this research background, and the solution of this model is given based on the orthogonal matrix property and multi-objective optimization algorithm includes the Particle Swarm Algorithm (PSO) and Difference Evolutionary Algorithm (DE). Verification experiments have shown that the method can achieve 3D camera calibration with an average error around 0.1021 mm in a large workspace. Thus, it is proved through experiments that this method can realize high-precision and high-robustness calibration of 3D camera, tool center point (TCP) coordinate, and tool axis vector in a large scale of operating environment.
The point cloud is one of the measurement results of local measurement and is widely used because of its high measurement accuracy, high data density, and low environmental impact. However, since point cloud data from a single measurement are generally small in spatial extent, it is necessary to accurately globalize the local point cloud to measure large components. In this paper, the method of using an iGPS (indoor Global Positioning System) as an external measurement device to realize high-accuracy globalization of local point cloud data is proposed. Two calibration models are also discussed for different application scenarios. Verification experiments prove that the average calibration errors of these two calibration models are 0.12 mm and 0.17 mm, respectively. The proposed method can maintain calibration precision in a large spatial range (about 10 m × 10 m × 5 m), which is of high value for engineering applications.