Elaheh Mashhour

Dr. Elaheh Mashhour

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
NDNoushin Davari
Noushin Davari
GAGholamreza Akbarizadeh
Gholamreza Akbarizadeh
EMElaheh Mashhour
Elaheh Mashhour
As one of the non-contact methods for incipient fault diagnosis of power distribution lines, UV-Visible imaging has become popular due to its good performance and robustness against environmental parameters. This paper presents a deep learning-based method for UV-Visible video processing. First, for preparing the dataset, some videos are acquired from distribution lines using CoroCam 6D2 considering observation distance, the imager's gain, air pressure, and humidity as effective parameters on the discharge area in the images. Then, based on the logged information of unplanned power outages in the system and also planned inspections over a year, the incipient fault type and the severity level of the incipient fault are determined for each video. For processing each video, frames are extracted with the rate according to the nominal voltage of the line. Power devices are detected in each frame using Faster R-CNN and are tracked through the whole video frames to compensate the camera movement. Then, color thresholding is used for each device to identify corona discharges in the frames. In-depth median filtering is also used through the video to eliminate noises in the UV channel. Finally, based on the ratio of the detected discharge area to the area of the equipment, the severity level of the incipient fault is determined. The proposed method not only performs better than the state-of-the-art but also is a practical method, and with the least dependence on environmental conditions, can automatically identify incipient faults in distribution lines, even in videos containing several possible defective devices.

29 September 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
NDNoushin Davari
Noushin Davari
GAGholamreza Akbarizadeh
Gholamreza Akbarizadeh
EMElaheh Mashhour
Elaheh Mashhour
This paper presents a deep learning-based method for defect detection and classification of power distribution lines using video analysis. The first stage is dataset preparation in which different videos are recorded by a CoroCam 6D2 camera from distribution lines and labeled based on the defect type and the severity level of the defect. Then, a process is followed in such a way that a limited number of frames are used for processing, and power devices are detected in each frame using Faster R-CNN. The detector performance is improved by increasing the training dataset and changing the training hyper-parameters. Next, an equipment tracking technique is applied through the video frames. In the following, a method based on the classification of power equipment is presented. In this method, by corona color thresholding in all frames and applying a median filter over time, the connected components representing the corona are identified. Then, the frame containing the closest component to the component in the median image is selected. In the selected frame, the area around the component is cut and given to AlexNet or GoogleNet to determine the equipment type and the severity level of defect is determined. Also, the defective equipment phase is determined based on the insulators detected in the video. The proposed method not only performs better than the state-of-the-art but also is a practical method, and with the least dependence on environmental conditions, can automatically identify defects in distribution lines, even in videos containing several possible defective devices.

1 June 2020 in Energy
Verified
Journal Article
Closed access
ARAmir Rafati
Amir Rafati
MJMahmood Joorabian
Mahmood Joorabian
EMElaheh Mashhour
Elaheh Mashhour


6 September 2024 in Algorithms
Verified
Journal Article
Open access
PDF file
QAQUSAY ALHAMD
QUSAY ALHAMD
MSMohsen Saniei
Mohsen Saniei
SSSeyyed Ghodratollah Seifossadat
Seyyed Ghodratollah Seifossadat
EMElaheh Mashhour
Elaheh Mashhour
Power transformers are vital and costly components in power systems, essential for ensuring a reliable and uninterrupted supply of electrical energy. Their protection is crucial for improving reliability, maintaining network stability, and minimizing operational costs. Previous studies have introduced differential protection schemes with harmonic restraint to detect internal transformer faults. However, these schemes often struggle with computational inaccuracies in fault detection due to neglecting current transformer (CT) saturation and associated uncertainties. CT saturation during internal faults can produce even harmonics, disrupting relay operations. Additionally, CT saturation during transformer energization can introduce a DC component, leading to incorrect relay activation. This paper introduces a novel feature extracted through advanced wavelet transform analysis of differential current. This feature, combined with differential current amplitude and bias current, is used to train a deep learning system based on long short-term memory (LSTM) networks. By accounting for existing uncertainties, this system accurately identifies internal transformer faults under various CT saturation and measurement uncertainty conditions. Test and validation results demonstrate the proposed method’s effectiveness and superiority in detecting internal faults in power transformers, even in the presence of CT saturation, outperforming other recent modern techniques.

2 August 2023 in Sustainable Energy, Grids and Networks
Verified
Journal Article
Closed access
SASaeed Azarhazin
Saeed Azarhazin
HFHossein Farzin
Hossein Farzin
EMElaheh Mashhour
Elaheh Mashhour