Rawan M. Jameel

Dr. Rawan M. Jameel

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
RJRawan M. Jameel
Rawan M. Jameel
AAAseel muhammed sadiq Alkhafaji
Aseel muhammed sadiq Alkhafaji
In different applied load scenarios, this study evaluates the distribution of stress in the implant and bone exerted by zirconia, lithium disilicate, and cobalt chromium alloy. A 3D virtual model of a mandibular three-unit implant-supported prosthesis was created using SolidWorks 2022. The model featured two 12-mm Straumann Ti-Zr (Roxolid) implants with diameters of 4.5 mm and 4 mm. Zirconia, lithium disilicate, and cobalt chromium alloy were used as superstructure materials. Vertical loads of 100 N and 200 N were applied to the central fossa of the implant-supported prosthesis. The finite element analysis demonstrated that doubling the applied load leads to a proportional increase in von Mises stress on both the implant and bone in a mandibular posterior three-unit implant-supported prosthesis model. Zirconia and chromium cobalt as superstructure materials result in similar stress levels due to their closely matched elastic moduli of 200 GPa and 218 GPa, respectively. In contrast, lithium disilicate leads to the highest stress levels, which is attributed to its lower elastic modulus of 95 GPa. These findings highlight the critical role of superstructure material properties in stress distribution. Zirconia emerges as the preferred material for implant-supported prosthetics due to its favorable stress distribution.

15 September 2025 in Journal of Baghdad College of Dentistry
Verified
Journal Article
Open access
PDF file
RJRawan M. Jameel
Rawan M. Jameel
LSLesovik V Stanislavovich
Lesovik V Stanislavovich
Background: Modern technologies in dentistry are one of ‎the effective ‏methods to obtain ‎results that are acceptable to the ‎‎patient, as well as reducing time, ‏effort, and ‏‎‎cost. ‏Materials and Methods: The effectiveness of the developed ‎digital ‎dental ‎treatment ‎‎‏planning was evaluated by assessing the results of ‎a survey of 50 ‎patients in need of ‎‎‎dental ‏‎implant prosthesis for aesthetic ‎‏faults ‎‎‎of the anterior tееth at the ‏prototype stage. The Oral ‏‎‎Health ‏Impact ‏Profile-14 (OHIP-14) was created to measure ‎the ‏impact that ‏oral health ‎issues can have on a person's life. ‎‎Results: after the mockup the ‏relative occlusal load distribution ‏‎between the right and left sides was 50.40 ± 0.90% with ‏balanced ‏‎occlusion.‏The dental closing time was 0.17± 0.07 s; and the dental ‎opening time ‏was 0.19 ±0.04 s. The difference in timing between the ‎left and right latеrntrusions is -0.030 ‎‎± 0.03. During protrusion, the ‎‎opening time was less than 0.6 s. (0.170 ± 0.07).‎‎ ‎‎ The ‏time ‎required to close the teeth to reach the maximum intercuspation was 0.20 ± 0.02 s, where the time required to open them was ‎‎0.170 ± 0.02 s. Conclusion: Prior to the mock-up, the patients' average relative occlusal load distribution was 51.5±1.20% on the left and right sides. After the mock-up, it was found that the relative occlusal load distribution between the left and right sides was 50.40±0.90%. These results point to stable and successful occlusal balance restoration following mock-up. After using the OHIP-14 questionnaire to summarize the survey results, we can say that patients' quality of life has enhanced by a factor of two.

1 January 2024
Verified
Journal Article
Open access
PDF file
RJRawan M. Jameel
Rawan M. Jameel
AAAseel muhammed sadiq Alkhafaji
Aseel muhammed sadiq Alkhafaji
This study was undertaken to assess the influence of different buccolingual offset of occlusal table on the stress distribution in bone, implant and prosthesis in four virtual models of 3_unit mandibular implant supported prosthesis. Materials and methods: Geometric models of prosthesis, implant, and mandibular bone were created using SolidWorks and Ansys. Four three-dimensional models of the mandibular posterior segment with a 3-unit implant-supported prosthesis were reconstructed. The models had buccolingual offsets of 70%, 80%, and 90%, and one model without an offset. Vertical forces of 100 N and 200 N were applied to analyze stress distribution. Results: At 100 N, optimal stress distribution is found in the 80% buccolingual offset model. At 200 N, the best stress distribution occurs in the 90% and 100% models. Stress behavior changes significantly with increased force. At 100 N, the second implant-supported molar in the 100% model experiences the least stress, while at 200 N, it experiences the most stress in the 70% model. Thus, the ideal stress distribution varies with load and buccolingual offset, with 80% being optimal at 100 N and higher offsets preferred at 200 N. Conclusion: The present research demonstrates that stress distribution in implant-supported prostheses varies with changes in the buccolingual width of the occlusal table. ANSYS calculations revealed that stress levels decrease as buccolingual width increases, with 80% buccolingual offset for appropriate stress distribution. Under a 100 N load, the ideal stress distribution is at 80% buccolingual offset. At a 200 N load, stress distribution varies significantly, with the lowest stress at 100% buccolingual width in the second implant-supported molar and the highest at 70% buccolingual width in the same area. Thus, stress transfer to the peri-implant bone varies with buccolingual offset, with 80% width being optimal under 100 N load.