Jan Kodet

Dr. Jan Kodet

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2020 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
AGAndré Gebauer
André Gebauer
MTMonika Tercjak
Monika Tercjak
KSKarl Ulrich Schreiber
Karl Ulrich Schreiber
HIHeiner Igel
Heiner Igel
JKJan Kodet
Jan Kodet
JWJon-Paul R. Wells
Jon-Paul R. Wells
Absolute rotation rate sensing with extreme sensitivity requires a combination of several large scale gyroscopes in order to obtain the full vector of rotation. We report on the construction and operation of a four-component, tetrahedral laser gyroscope array as large as a five story building and situated in a near surface, underground laboratory. It is demonstrated that reconstruction of the full Earth rotation vector can be achieved with sub-arcsecond resolution over more than six weeks.

16 December 2015 in Metrologia
Verified
Journal Article
Open access
PDF file
JKJan Kodet
Jan Kodet
PPPetr Pánek
Petr Pánek
IPIvan Procházka
Ivan Procházka
We are reporting on analysis, design, construction, and key parameters of the device for a two-way time transfer via an optical fiber. The dominant source of errors in the two-way optical time transfer (TWOTT) via relatively short optical fibers is the temperature dependence of internal delays within the terminal units. We have performed an analysis of the influence of the internal delays and their temperature dependence on the TWOTT process considering two different configurations of the terminals with the feedback coupling in optical and electrical domains. The achieved results have been used for the optimal design of a TWOTT system implementing standard small form-factor pluggable optical transceivers. The operational tests of this new TWOTT system confirmed the precision of the time transfer on the subpicosecond level, the time transfer stability characterized by TDEV better than 60 fs for averaging intervals from 100 s to 10 000 s, and the temperature stability better than 100 fs K-1 .

20 December 2017 in Space Science Reviews
Verified
Journal Article
Open access
PDF file
KSKarl Ulrich Schreiber
Karl Ulrich Schreiber
JKJan Kodet
Jan Kodet
Highly precise time and stable reference frequencies are fundamental requirements for space geodesy. Satellite laser ranging (SLR) is one of these techniques, which differs from all other applications like Very Long Baseline Interferometry (VLBI), Global Navigation Satellite Systems (GNSS) and finally Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS) by the fact that it is an optical two-way measurement technique. That means that there is no need for a clock synchronization process between both ends of the distance covered by the measurement technique. Under the assumption of isotropy for the speed of light, SLR establishes the only practical realization of the Einstein Synchronization process so far. Therefore it is a powerful time transfer technique. However, in order to transfer time between two remote clocks, it is also necessary to tightly control all possible signal delays in the ranging process. This paper discusses the role of time and frequency in SLR as well as the error sources before it address the transfer of time between ground and space. The need of an improved signal delay control led to a major redesign of the local time and frequency distribution at the Geodetic Observatory Wettzell. Closure measurements can now be used to identify and remove systematic errors in SLR measurements.

17 September 2022 in The European Physical Journal C
Verified
Journal Article
Open access
PDF file
AVAngela Dora Vittoria Di Virgilio
Angela Dora Vittoria Di Virgilio
GTG. Terreni
G. Terreni
ABA. Basti
A. Basti
NBNicolo' Beverini
Nicolo' Beverini
GCGiorgio Carelli
Giorgio Carelli
KSKarl Ulrich Schreiber
Karl Ulrich Schreiber
The absolute measurement of the Earth angular rotation rate with ground-based instruments becomes challenging if the 1 part in $$10^9$$ 10 9 of precision has to be obtained. This threshold is important for fundamental physics and for geodesy, to investigate effects of General Relativity and Lorentz violation in the gravity sector and to provide the fast variation of the Earth rotation rate. High sensitivity Ring Laser Gyroscopes (RLG) are currently the only promising technique to achieve this task in the near future, but their precision has been so far limited by systematics related to the laser operation. In this paper we analyze two different sets of observations, each of them three days long. They were obtained from the G ring laser at the Geodetic Observatory Wettzell. The applied method has been developed for the GINGERINO ring laser in order to identify and extract the laser systematics. For the available data sets the residuals show mostly white noise behavior and the Allan deviation drops below 1 part in $$10^9$$ 10 9 after an integration time of about $$10^4$$ 10 4 s.

17 January 2018 in Journal of Geodesy
Verified
Journal Article
Closed access
PDF file
JKJan Kodet
Jan Kodet
KSKarl Ulrich Schreiber
Karl Ulrich Schreiber
JEJ. Eckl
J. Eckl
CPC. Plötz
C. Plötz
SMS. Mähler
S. Mähler
SRS. Riepl
S. Riepl

1 May 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
IPIvan Prochazka
Ivan Prochazka
JKJan Kodet
Jan Kodet
JBJosef Blazej
Josef Blazej
The laser time transfer link is under construction for the European Space Agency in the frame of Atomic Clock Ensemble in Space. We have developed and tested the flying unit of the photon counting detector optimized for this space mission. The results are summarized in this Note. An extreme challenge was to build a detector package, which is rugged, small and which provides long term detection delay stability on picosecond level. The device passed successfully all the tests required for space missions on the low Earth orbits. The detector is extremely rugged and compact. Its long term detection delay stability is excellent, it is better than ±1 ps/day, in a sense of time deviation it is better than 0.5 ps for averaging times of 2000 s to several hours. The device is capable to operate in a temperature range of −55 °C up to +60 °C, the change of the detection delay with temperature is +0.5 ps/K. The device is ready for integration into the space structure now.