ATP-dependent RAD51 recombinases play an essential role in eukaryotic homologous recombination by catalyzing a four-step process: 1) formation of a RAD51 single-filament assembly on ssDNA in the presence of ATP, 2) complementary DNA strand-exchange, 3) ATP hydrolysis transforming the RAD51 filament into an ADP-bound disassembly-competent state, and 4) RAD51 disassembly to provide access for DNA repairing enzymes. Of these steps, filament dynamics between the ATP- and ADP-bound states, and the RAD51 disassembly mechanism, are poorly understood due to the lack of near-atomic-resolution information of the ADP-bound RAD51–DNA filament structure. We report the cryo-EM structure of ADP-bound RAD51–DNA filaments at 3.1 Å resolution, revealing a unique RAD51 double-filament that wraps around ssDNA. Structural analysis, supported by ATP-chase and time-resolved cryo-EM experiments, reveals a collapsing mechanism involving two four-protomer movements along ssDNA for mechanical transition between RAD51 single- and double-filament without RAD51 dissociation. This mechanism enables elastic change of RAD51 filament length during structural transitions between ATP- and ADP-states.
1 January 2020 in Annals of Mathematical Sciences and Applications
2D classification plays a pivotal role in analyzing single particle cryo-electron microscopy images. Here, we introduce a simple and loss-less pre-processor that incorporates a fast dimension-reduction (2SDR) de-noiser to enhance 2D classification. By implementing this 2SDR pre-processor prior to a representative classification algorithm like RELION and ISAC, we compare the performances with and without the pre-processor. Tests on multiple cryo-EM experimental datasets show the pre-processor can make classification faster, improve yield of good particles and increase the number of class-average images to generate better initial models. Testing on the nanodisc-embedded TRPV1 dataset with high heterogeneity using a 3D reconstruction workflow with an initial model from class-average images highlights the pre-processor improves the final resolution to 2.82 Å, close to 0.9 Nyquist. Those findings and analyses suggest the 2SDR pre-processor, of minimal cost, is widely applicable for boosting 2D classification, while its generalization to accommodate neural network de-noisers is envisioned.
Background: Much of the microarray data published at Stanford is based on mouse and human arrays produced under controlled and monitored conditions at the Brown and Botstein laboratories and at the Stanford Functional Genomics Facility (SFGF). Nevertheless, as large datasets based on the Stanford Human array began to accumulate, a small but significant number of discrepancies were detected that required a serious attempt to track down the original source of error. Due to a controlled process environment, sufficient data was available to accurately track the entire process leading to up to the final expression data. In this paper, we describe our statistical methods to detect the inconsistencies in microarray data that arise from process errors, and discuss our technique to locate and fix these errors. Results: To date, the Brown and Botstein laboratories and the Stanford Functional Genomics Facility have together produced 40,000 large-scale (10–50,000 feature) cDNA microarrays. By applying the heuristic described here, we have been able to check most of these arrays for misidentified features, and have been able to confidently apply fixes to the data where needed. Out of the 265 million features checked in our database, problems were detected and corrected on 1.3 million of them. Conclusion: Process errors in any genome scale high throughput production regime can lead to subsequent errors in data analysis. We show the value of tracking multi-step high throughput operations by using this knowledge to detect and correct misidentified data on gene expression microarrays.
Cell division in Escherichia coli is intricately regulated by the MinD and MinE proteins, which form oscillatory waves between cell poles. These waves manifest as concentration gradients that reduce MinC inhibition at the cell center, thereby influencing division site placement. This study explores the plasticity of the MinD gradients resulting from the interdependent interplay between molecular interactions and diffusion in the system. Through live cell imaging, we observed that as cells elongate, the gradient steepens, the midcell concentration decreases, and the oscillation period stabilizes. A one-dimensional model investigates kinetic rate constants representing various molecular interactions, effectively recapitulating our experimental findings. The model reveals the nonlinear dynamics of the system and a dynamic equilibrium among these constants, which underlie variable concentration gradients in growing cells. This study enhances quantitative understanding of MinD oscillations within the cellular environment. Furthermore, it emphasizes the fundamental role of concentration gradients in cellular processes.
1 October 2025 in Proceedings on Privacy Enhancing Technologies
Third-generation Fully Homomorphic Encryption (FHE), particularly the FHEW/TFHE schemes, is recognized for its balanced security requirements, small parameters, and low memory usage, though the current methods in the scenarios of Deep Neural Network (DNN) inference still have high computational costs, limiting the practical applicability. This work demonstrates how to improve practicality of the third-generation technologies for DNN tasks while preserving its key advantages. Our work focuses on two main contributions. First, we developed a computational architecture called FHE-Neuron, which reconfigures the parameters and bootstrapping structure of traditional FHEW/TFHE Boolean operations. This architecture significantly reducing the cost of encrypted DNN inference by dynamically switching the precision of encrypted data during computation—using high precision for cost-effective linear operations and low precision for computationally expensive nonlinear operations. Second, we introduced an FHE-aware Quantization and Fine-tuning framework that optimizes model parameters to align with FHE-Neuron’s constraints, ensuring high accuracy in encrypted inference. We validate our approach on various neural network models across several computing platforms. In our experiments, our method achieves one-image inference time on average 4.5 milliseconds for MNIST and 17 milliseconds for Fashion MNIST, achieving accuracy rates of 96.52% and 88.57% respectively. For the CIFAR-10 dataset, our system completes one image inference in 30 seconds with a 90.5% accuracy rate.