Jason Ina

Dr. Jason Ina


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PMPaul D. Marasco
Paul D. Marasco
DBDennis J. Bourbeau
Dennis J. Bourbeau
CSCourtney E. Shell
Courtney E. Shell
RGRafael Granja-Vazquez
Rafael Granja-Vazquez
JIJason Ina
Jason Ina
Kinesthesia is the sense of limb movement. It is fundamental to efficient motor control, yet its neurophysiological components remain poorly understood. The contributions of primary muscle spindles and cutaneous afferents to the kinesthetic sense have been well studied; however, potential contributions from muscle sensory group responses that are different than the muscle spindles have not been ruled out. Electrophysiological recordings in peripheral nerves and brains of male Sprague Dawley rats with a degloved forelimb preparation provide evidence of a rapidly adapting muscle sensory group response that overlaps with vibratory inputs known to generate illusionary perceptions of limb movement in humans (kinesthetic illusion). This group was characteristically distinct from type Ia muscle spindle fibers, the receptor historically attributed to limb movement sensation, suggesting that type Ia muscle spindle fibers may not be the sole carrier of kinesthetic information. The sensory-neural structure of muscles is complex and there are a number of possible sources for this response group; with Golgi tendon organs being the most likely candidate. The rapidly adapting muscle sensory group response projected to proprioceptive brain regions, the rodent homolog of cortical area 3a and the second somatosensory area (S2), with similar adaption and frequency response profiles between the brain and peripheral nerves. Their representational organization was muscle-specific (myocentric) and magnified for proximal and multi-articulate limb joints. Projection to proprioceptive brain areas, myocentric representational magnification of muscles prone to movement error, overlap with illusionary vibrational input, and resonant frequencies of volitional motor unit contraction suggest that this group response may be involved with limb movement processing.

1 April 2024 in JBJS Reviews
Verified
Journal Article
Closed access
LHLucas Haase
Lucas Haase
JIJason Ina
Jason Ina
EHEthan Harlow
Ethan Harlow
RCRaymond Chen
Raymond Chen
RGRobert Gillespie
Robert Gillespie
JCJacob Calcei
Jacob Calcei
» Reverse total shoulder arthroplasty was designed to function in the rotator cuff deficient shoulder by adjusting the glenohumeral center of rotation (COR) to maximize deltoid function. » Adjustments in the COR ultimately lead to changes in resting tension of the deltoid and remaining rotator cuff, which can affect implant stability and risk of stress fracture. » Soft-tissue balance and complication profiles can be affected by humeral component (version, neck shaft angle, and inlay vs. onlay) and glenoid component (sagittal placement, version, inclination, and lateralization) design and application. » A good understanding of the effects on soft-tissue balance and complication profile is critical for surgeons to best provide optimal patient outcomes.

13 March 2018 in Metals
Verified
Journal Article
Open access
PDF file
JIJason Ina
Jason Ina
MVMadhurima Vallentyne
Madhurima Vallentyne
FHFarah Mohammed Ridha A Hamandi
Farah Mohammed Ridha A Hamandi
KSKathleen Shugart
Kathleen Shugart
MBMichael Boin
Michael Boin
Tarun GoswamiTarun Goswami
Tarun Goswami
The failure of a proximal humerus internal locking system (PHILOS) used in a pantalar arthrodesis was investigated in this paper. PHILOS constructs are hybrids using locking and non-locking screws. Both the plate and the screws used in the fusion were obtained for analysis. However, only the plate failure analysis is reported in this paper. The implant had failed in several pieces. Optical and scanning electron microscopic analyses were performed to characterize the failure mode(s) and fracture surface. The chemical composition and mechanical properties of the plate were determined and compared to controlling specifications to manufacture the devices. We found that equivalent tensile strength exceeded at the locations of high stress, axial, and angular displacement and matched the specification at the regions of lower stress/displacement. Such a region-wise change in mechanical properties with in vivo utilization has not been reported in the literature. Evidence of inclusions was qualitatively determined for the stainless steel 316L plate failing the specifications. Pitting corrosion, scratches, discoloration and debris were present on the plate. Fracture surface showed (1) multi-site corrosion damage within the screw holes forming a 45° maximum shear force line for crack-linking, and (2) crack propagation perpendicular to the crack forming origin that may have formed due to the presence of inclusions. Fracture features such as beach marks and striations indicating that corrosion may have initiated the crack(s), which grew by fatigue over a period of time. In conclusion, the most likely mechanism of failure for the device was due to corrosion fatigue and lack of bony in-growth on the screws that may have caused loosening of the device causing deformity and pre-mature failure.

17 February 2022 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
JIJason Ina
Jason Ina
AVAjit Vakharia
Ajit Vakharia
OAOzan Akkus
Ozan Akkus
CRClare M. Rimnac
Clare M. Rimnac
Background: Structural cortical bone allografts are a reasonable treatment option for patients with large cortical bone defects caused by trauma, tumors, or complications of arthroplasty. Although structural cortical bone allografts provide the benefit of an osteoconductive material, they are susceptible to fatigue failure (fracture) and carry a risk of disease transmission. Radiation-sterilization at the recommended dose of 25 kGy decreases the risk of disease transmission. However, previous studies demonstrated that radiation sterilization at this dose can negatively impact the high cycle-fatigue life of cortical bone. Although the effects of higher doses of radiation on cortical bone allografts are well described, the effects of lower doses of radiation on a high-cycle fatigue life of cortical bone are poorly understood. Questions/purposes: (1) Does the cycle-fatigue life of human cortical allograft bone vary with gamma radiation dose levels of 0 (control), 10 kGy, 17.5 kGy, and 25 kGy? (2) What differences in Raman spectral biomarkers are observed following varying doses of gamma radiation exposure? Methods: The high-cycle fatigue behavior of human cortical bone specimens was examined at different radiation sterilization doses under physiologic stress levels (35 MPa) and in a 37° C phosphate-buffered saline bath using a custom-designed rotating-bending fatigue device. Six human femora from three donors were obtained for this study (two male, 63 and 61 years old, respectively, and one female, 48 years old). Test specimens were allocated among four treatment groups (0 kGy [control], 10 kGy, 17.5 kGy, and 25 kGy) based on donor and anatomic location of harvest site (both length and cross-sectional quadrant of femoral diaphysis) to ensure equal variation (n = 13 per group). Specimens underwent high-cycle fatigue testing to failure. The number of cycles to failure was recorded. Raman spectroscopy (a noninvasive vibrational spectroscopy used to qualitatively assess bone quality) was used to detect whether any changes in Raman spectral biomarkers occurred after varying doses of gamma radiation exposure. Results: There was a decrease in the log-transformed mean high-cycle fatigue life in specimens irradiated at 25 kGy (5.39 ± 0.32) compared with all other groups (0 kGy: 6.20 ± 0.50; 10k Gy: 6.35 ± 0.79; 17.5 kGy: 6.01 ± 0.53; p = 0.001). Specimens irradiated at 25 kGy were also more likely to exhibit a more brittle fracture surface pattern than specimens with more ductile fracture surface patterns irradiated at 0 kGy, 10 kGy, and 17.5 kGy (p = 0.04). The Raman biomarker for the ratio of the relative amount of disordered collagen to ordered collagen showed a decrease at the 10 kGy radiation level from 1.522 ± 0.025 preirradiation to 1.489 ± 0.024 postirradiation (p = 0.01); no other detectable changes in Raman biomarkers were observed. Conclusion: The high-cycle fatigue life of cortical bone undergoes a nonlinear, dose-dependent decrease with an increase in gamma radiation sterilization in a clinically relevant dose range (0-25 kGy). Importantly, a notable drop-off in the high-cycle fatigue life of cortical bone appeared to occur between 17.5 kGy and 25 kGy, correlating to a sixfold decrease in mean cycles to failure. We speculate that the decrease in the Raman biomarker for disordered collagen at 10 kGy with no loss in high-cycle fatigue life may be caused by an increased amount of nonenzymatic crosslinking of the collagen backbone relative to collagen chain-scission (whereas the benefits of crosslinking may be outweighed by excess scission of the collagen backbone at higher radiation doses), but future studies will need to ascertain whether this in fact is the case. Clinical Relevance: Radiation sterilization at the industry standard of 25 kGy has a substantial negative impact on the high-cycle fatigue life of cortical bone. Given these findings, it is possible to provide a meaningful increase in the high-cycle fatigue life and improve the overall functional lifetime of cortical bone allografts by lowering the radiation-sterilization dose below 25 kGy. Future work on radiation-sterilization methods at these clinically relevant doses is warranted to aid in preserving the high cycle fatigue life of cortical bone allografts while maintaining sterility.

1 August 2021 in JBJS Reviews
Verified
Journal Article
Closed access
JIJason Ina
Jason Ina
YRYazdan Raji
Yazdan Raji
JSJohn T. Strony
John T. Strony
CSCharles Su
Charles Su
SNShane Nho
Shane Nho
MSMichael J. Salata
Michael J. Salata
» Femoroacetabular impingement (FAI) is one of the most common causes of early hip articular cartilage wear and labral damage, and subsequently leads to the onset of hip osteoarthritis. » Cam-type FAI impingement lesions can be best identified with a 90° Dunn lateral radiograph and a cross-table lateral radiograph with 15° of internal rotation; the alpha angle and the femoral head-neck offset are the most used predictive radiographic markers. » FAI lesions with pincer impingement are associated with acetabular retroversion and are more difficult to identify on traditional radiographic imaging; however, the presence of a crossover sign, an ischial spine sign, and/or a posterior wall sign can be useful radiographic markers. » Advanced imaging modalities such as magnetic resonance imaging (MRI) and/or magnetic resonance arthrography (MRA) can also be beneficial in the evaluation of FAI and labral pathology; MRA is more sensitive than MRI in detecting intra-articular pathology. » Computer-assisted navigation for preoperative planning and intraoperative surgical assistance are promising technologies; however, additional studies are needed before they can be utilized safely and effectively.

26 July 2021 in HIP International
Verified
Journal Article
Closed access
PDF file
CSCharles A Su
Charles A Su
MLMark W LaBelle
Mark W LaBelle
JIJason Ina
Jason Ina
LSLakshmanan Sivasundaram
Lakshmanan Sivasundaram
SNShane Nho
Shane Nho
MSMichael J Salata
Michael J Salata
To define the anatomical relationship of the major neurovascular structures to the standard endoscopic portals used in endoscopic hamstring repair. A secondary outcome was to determine the safest angle of insertion from each standard portal. Endoscopic portals were established in the 3 standard locations (lateral, medial, and inferior) and Steinmann pins inserted at various angles. Each hip was dissected and the distance between the pins and the pertinent anatomy measured. The lateral portal placed the sciatic and posterior femoral cutaneous (PFC) nerves at greatest risk: direct injury to the sciatic nerve was seen in 11/30 (37%) of the lateral portals sited. A lateral portal with an approach at 60° was the most dangerous orientation with a mean distance of 0.36 ± 0.49 mm and 4.30 ± 2.69 mm from the sciatic and PFC nerves, respectively (p < 0.001). The 60° medial portal was the safest of all portals measured, at a mean distance of 67.37 ± 11.06mm (range, 47–78 mm) from the sciatic nerve and 58.90 ± 10.57 mm (range 40–70 mm) from the PFC nerve. While currently described techniques recommend establishing the standard lateral portal first, this study shows that it carries the highest risk of injury if used blind. We recommend that the standard medial endoscopic portal is established first to identify the neurovascular structures and minimise iatrogenic neurovascular injury. The inferior and lateral portals can then be established created under direct vision. The lateral portal should be inserted in a more horizontal orientation to decrease the risk of nerve injury.