Richard Kutame

Mr. Richard Kutame


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
RKRichard Kutame
Richard Kutame
GBGifty Boateng
Gifty Boateng
YAYaw Adusi-Poku
Yaw Adusi-Poku
FSFelix Sorvor
Felix Sorvor
LALorreta Antwi
Lorreta Antwi
FAFranklin Asiedu-Bekoe
Franklin Asiedu-Bekoe
Interferon-gamma release assays (IGRAs) have gained attention for the diagnosis of latent tuberculosis infection (LTBI) due to their higher specificity compared to the tuberculin skin test (TST). However, the IGRA’s performance varies across different populations. This study evaluated the diagnostic performance of three IGRAs (TBF-FIA, TBF-ELISA, and QFT-Plus) in Ghana, comparing them among individuals exposed and unexposed to MTB infection. Conducted in TB clinics across three regions, this prospective and cross-sectional study included healthy individuals with no known TB exposure (unexposed group) and patients with confirmed active TB (exposed group). Blood samples were tested using all three assays as per the manufacturers’ guidelines. The TBF-ELISA showed 3.4% higher sensitivity but 4.6% lower specificity compared to QFT-Plus. The TBF-FIA had sensitivity of 78.5–87.3% and specificity of 82.9–90.0%. These findings indicate that while the three IGRAs offer similar diagnostic accuracy, the variations in specificity and limited data on assays like TBF-FIA require further investigation.

22 August 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
RKRichard Kutame
Richard Kutame
GBGifty Boateng
Gifty Boateng
YAYaw Adusi-Poku
Yaw Adusi-Poku
FSFelix Sorvor
Felix Sorvor
LALorreta Antwi
Lorreta Antwi
FAFranklin Asiedu-Bekoe
Franklin Asiedu-Bekoe
Interferon-gamma release assays (IGRAs) gained attention for diagnosing latent tuberculosis infection (LTBI) due to their higher specificity compared to the tuberculin skin test (TST). However, IGRA performance varied across different populations. This study evaluated the diagnostic performance of three IGRA assays (TBF-FIA, TBF-ELISA, and QFT-Plus) in Ghana, comparing them among individuals exposed and unexposed to MTB infection. Conducted in TB clinics across three regions, this prospective and cross-sectional study included healthy individuals with no known TB exposure (unexposed group) and patients with confirmed active TB (exposed group). Blood samples were tested using all three assays per manufacturers’ guidelines. The TBF-ELISA showed 3.4% higher sensitivity, but 4.6% lower specificity compared to QFT-Plus. The TBF-FIA had a sensitivity of 78.5%-87.3% and a specificity of 82.9%-90.0%. These findings indicated that while the three IGRA assays offered similar diagnostic accuracy, variations in specificity and limited data on point-of-care assays like TBF-FIA required further investigation.