Pingping Jiang

Dr. Pingping Jiang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
WWWei Wang
Wei Wang
GYGuozheng Yan
Guozheng Yan
ZWZhiwu Wang
Zhiwu Wang
PJPingping Jiang
Pingping Jiang
YMYicun Meng
Yicun Meng
RXRongrong Xue
Rongrong Xue
In order to make the gastrointestinal microrobot (GMR) expand and anchor in the gastrointestinal tract reliably, a novel expanding mechanism of the GMR is proposed in this paper. The overlapping expanding arm is designed to be used to increase the variable diameter ratio (ratio of fully expanded diameter to fully folded diameter) to 3.3, which makes the robot more adaptable to the intestinal tract of different sections of the human body. The double-layer structure of the expanding arm increases the contact area with the intestine, reducing the risk of intestinal damage. The kinematics and mechanical model of the expanding arm are established, and the rigid velocity, rigid acceleration, and expanding force of the expanding arm are analyzed. The elastodynamics model of the expanding arm is established. Through the finite element analysis (FEA), the velocity, acceleration, and the value and distribution of the stress of the expanding arm under elastic deformation are obtained. Based on the elastodynamics analysis, the structure of the expanding arm is optimized. By the structure optimization, the thickness of the expanding mechanism is reduced by 0.4mm, the weight is reduced by 31%, and the stress distribution is more uniform. Through the mechanical test, the minimum expanding force of the expanding mechanism is 1.3 N and the maximum expanding force is 6.5 N. Finally, the robot is tested in the rigid pipeline and the isolated intestine to verify the reliability and safety of the expanding mechanism.

21 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MLMian Liu
Mian Liu
ZWZhiwu Wang
Zhiwu Wang
PJPingping Jiang
Pingping Jiang
GYGuozheng Yan
Guozheng Yan
Piezoresistive pressure sensors have broad applications but often face accuracy challenges due to temperature-induced drift. Traditional compensation methods based on discrete data, such as polynomial interpolation, support vector machine (SVM), and artificial neural network (ANN), overlook the thermal hysteresis, resulting in lower accuracy. Considering the sequence-dependent nature of temperature drift, we propose the RF-IWOA-GRU temperature compensation model. Random forest (RF) is used to interpolate missing values in continuous data. A combination of gated recurrent unit (GRU) networks and an improved whale optimization algorithm (IWOA) is employed for temperature compensation. This model leverages the memory capability of GRU and the optimization efficiency of the IWOA to enhance the accuracy and stability of the pressure sensors. To validate the compensation method, experiments were designed under continuous variations in temperature and actual pressure. The experimental results show that the compensation capability of the proposed RF-IWOA-GRU model significantly outperforms that of traditional methods. After compensation, the standard deviation of pressure decreased from 10.18 kPa to 1.14 kPa, and the mean absolute error and root mean squared error were reduced by 75.10% and 76.15%, respectively.

27 September 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
DHDing Han
Ding Han
GYGuozheng Yan
Guozheng Yan
ZWZhiwu Wang
Zhiwu Wang
PJPingping Jiang
Pingping Jiang
DLDasheng Liu
Dasheng Liu
JMJin Ma
Jin Ma
Intestinal-related diseases all around the world are increasing nowadays, and gradually become stubborn diseases threatening human health, and even lives. Diagnosis methods have attracted more and more attention. This article concerns a non-invasive way, a novel micro-robot, to diagnose intestinal diseases. This proposed micro-robot is a swallowable device, 14 mm in diameter, like a capsule. In order to make it possible for the micro-robot to move forward, backward, or anchor itself at a suspicious lesion point in the intestine with different lumen diameter sections, two key mechanisms have been proposed. One is an expanding mechanism with two-layer folded legs for anchoring. The designed expanding mechanism could realize a large variable diameter ratio, upwards of 3.43. In addition, a pair of specific annular gears instead of a traditional pinion drive is devised not only saving limited space, but also reducing energy loss. The other mechanism is a telescoping mechanism, possessing a self-locking lead screw nut system, which is used to obtain axial motion of the micro-robot. Then, the kinematics and dynamics of the micro-robot are analyzed. After that, the following experiments, including force tests and locomotion tests, are constructed. A good match is found between the theoretical results and the experimental data. Finally, in vitro experiments are performed with a prototype to verify the safety and reliability of the proposed micro-robot in porcine intestine.

28 January 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DHDing Han
Ding Han
RWRenqing Wen
Renqing Wen
GYGuozheng Yan
Guozheng Yan
Dahong QianDahong Qian
Dahong Qian
SKShuai KUANG
Shuai KUANG
ZWZhiwu Wang
Zhiwu Wang
Wireless power transfer (WPT) in weak coupling has recently received widespread attention because it could be used to supply energy to capsule robots (CRs), allowing CRs (580 mW needed) to diagnose and treat diseases in the human body. In particular, exciting a three-dimensional (3-D) alternating magnetic field (AMF) for powering CRs has always been challenging since the randomly changing attitude and position can destabilize the induced power received by the coil on the CR. In this article, a novel WPT system based on three-dimensional hybrid transmitting coils (3DHTC) is proposed to generate stable energy for the CR. 3DHTC is a 3-D orthogonal coil system, consisting of a Helmholtz coil pair and two saddle-shaped coil pairs. The dimension of the 3DHTC is Φ70 × 35 mm. It can basically cover a 30 cm × 30 cm area of the human abdomen the design and implementation details of the new 3DHTC system are presented in this article. The 3DHTC system has been proven to excite a uniform and stable AMF covering the CR workspace by both analytical calculation and simulation analysis. Furthermore, a 1-D receiving coil (1DRC, Φ14 × 14 mm) is employed in the experiments to measure the AMF generated by the 3DHTC for its performance evaluation. The experiments illustrate the 3DHTC can supply stable energy of at least 777.63 mW to the 1DRC with randomly changing attitudes and positions, and the corresponding transfer efficiency ranges from 8.1% to 13.61%.

26 January 2021 in Journal of Shanghai Jiaotong University (Science)
Verified
Journal Article
Closed access
PDF file
FCFanji Chen
Fanji Chen
PJPingping Jiang
Pingping Jiang
GYGuozheng Yan
Guozheng Yan
WWWei Wang
Wei Wang
YMYicun Meng
Yicun Meng

30 July 2025 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
RWRenqing Wen
Renqing Wen
GYGuozheng Yan
Guozheng Yan
DHDing Han
Ding Han
SKShuai Kuang
Shuai Kuang
PJPingping Jiang
Pingping Jiang
ZWZhiwu Wang
Zhiwu Wang