Jin W. Choi

Prof. Jin W. Choi

School of Electrical Engineering and Computer Science, Louisiana State University, Baton Rouge, LA 70803, USA
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Microelectronic Engineering
Verified
Journal Article
Closed access
WJWooseok Jung
Wooseok Jung
JHJungyoup Han
Jungyoup Han
JCJin W. Choi
Jin W. Choi
CAChong H. Ahn
Chong H. Ahn

7 August 2013 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ESEdward Song
Edward Song
JCJin W. Choi
Jin W. Choi
One dimensional polyaniline nanowire is an electrically conducting polymer that can be used as an active layer for sensors whose conductivity change can be used to detect chemical or biological species. In this review, the basic properties of polyaniline nanowires including chemical structures, redox chemistry, and method of synthesis are discussed. A comprehensive literature survey on chemiresistive/conductometric sensors based on polyaniline nanowires is presented and recent developments in polyaniline nanowire-based sensors are summarized. Finally, the current limitations and the future prospect of polyaniline nanowires are discussed.

10 February 2004 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CHChien-Chong Hong
Chien-Chong Hong
JCJin W. Choi
Jin W. Choi
CAChong H. Ahn
Chong H. Ahn
An innovative in-plane passive micromixer using modified Tesla structures, which are used as passive valves, has been designed, simulated, fabricated and successfully characterized in this paper. Simulation and experimental results of the developed novel micromixer have shown excellent mixing performance over a wide range of flow conditions in the micro scale. The micromixer realized in this work has achieved even better mixing performance at a higher flow rate, and its pressure drop is less than 10 KPa at the flow rate of 100 µl min−1. This micromixer shows characteristics similar to Taylor dispersion, with contributions from both diffusion and convection. The mixer has a diffusion domain region at low flow rate, but it moves to a convection domain region at high flow rate. Due to the simple in-plane structure of the novel micromixer explored in this work, the mixer can be easily realized and integrated with on-chip microfluidic devices and micro total analysis systems (μ-TAS).

6 December 2001 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
JCJin W. Choi
Jin W. Choi
KOKwang W. Oh
Kwang W. Oh
JTJennifer H. Thomas
Jennifer H. Thomas
WHWilliam R. Heineman
William R. Heineman
HHH. Brian Halsall
H. Brian Halsall
CAChong H. Ahn
Chong H. Ahn
This paper presents the development and characterization of an integrated microfluidic biochemical detection system for fast and low-volume immunoassays using magnetic beads, which are used as both immobilization surfaces and bio-molecule carriers. Microfluidic components have been developed and integrated to construct a microfluidic biochemical detection system. Magnetic bead-based immunoassay, as a typical example of biochemical detection and analysis, has been successfully performed on the integrated microfluidic biochemical analysis system that includes a surface-mounted biofilter and electrochemical sensor on a glass microfluidic motherboard. Total time required for an immunoassay was less than 20 min including sample incubation time, and sample volume wasted was less than 50 μl during five repeated assays. Fast and low-volume biochemical analysis has been successfully achieved with the developed biofilter and immunosensor, which is integrated to the microfluidic system. Such a magnetic bead-based biochemical detection system, described in this paper, can be applied to protein analysis systems.

1 January 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
YSYoung-Ho Shin
Young-Ho Shin
MGM. Teresa Gutierrez-Wing
M. Teresa Gutierrez-Wing
JCJin W. Choi
Jin W. Choi
Portable fluorescence sensors have been developed for biochemical detection, water quality monitoring, biomedical sensing, and many other applications. With help of advancement in modern electronics, conventional fluorescence-based instrumentations are now integrated into portable sensing devices for remote and resource-limited settings. In this work, fluorescence sensing technology is introduced and different applications of portable fluorescence sensors and their characteristics are reviewed. Current issues, technological challenges, and future direction of the portable fluorescence sensor development are discussed. The goal is to provide a comprehensive survey on the recent advancements in optics, semiconductors, smartphones, and many other manufacturing technologies that increased the portability, miniaturization, and sensitivity of portable fluorescence sensor devices.

26 October 2012 in Nanomaterials
Verified
Journal Article
Open access
PDF file
CLChao-Xuan Liu
Chao-Xuan Liu
JCJin W. Choi
Jin W. Choi
The polymer nanocomposite used in this work comprises elastomer poly(dimethylsiloxane) (PDMS) as a polymer matrix and multi-walled carbon nanotubes (MWCNTs) as a conductive nanofiller. To achieve uniform distribution of carbon nanotubes within the polymer, an optimized dispersion process was developed, featuring a strong organic solvent—chloroform, which dissolved PDMS base polymer easily and allowed high quality dispersion of MWCNTs. At concentrations as high as 9 wt.%, MWCNTs were dispersed uniformly through the polymer matrix, which presented a major improvement over prior techniques. The dispersion procedure was optimized via extended experimentation, which is discussed in detail.