Standard roadside vegetated swales often do not provide consistent pollutant removal. To increase infiltration and pollutant removal, bioswales are designed with an underlying soil media and an underdrain. However, there are little data on the ability of these stormwater control measures (SCMs) to reduce pollutant concentrations. A bioswale treating road runoff was monitored, with volume-proportional, composite stormwater runoff samples taken for the inlet, overflow, and underdrain outflow. Samples were tested for total suspended solids (TSS), total volatile suspended solids (VSS), enterococcus, E. coli, and turbidity. Underdrain flow was significantly cleaner than untreated road runoff for all monitored pollutants. As expected, the water quality of overflow was not significantly improved, since little to no interaction with soils occurred for this portion of the water balance. However, overflow bacteria concentrations were similar to those from the underdrain perhaps due to a first flush of bacteria which was treated by the soil media. For all sampling locations, enterococci concentrations were always higher than the USEPA geometric mean recommendation of 35 Most Probable Number (MPN)/100 mL, but there were events where the fecal coliform concentrations was below the USEPA’s 200 MPN/100 mL limit. A reduction in TSS concentration was seen for both overflow and underdrain flow, and only the underdrain effluent concentrations were below the North Carolina’s high quality water limit of 20 mg/L. Comparing results herein to standard swales, the bioswale has the potential to provide greater treatment and become a popular tool.
Bioswales are a promising stormwater control measure (SCM) for roadway runoff management, but few studies have assessed performance on a field scale. A bioswale is a vegetated channel with underlying engineered media and a perforated underdrain to promote improved hydrologic and water quality treatment. A bioswale with a rip-rap lined forebay was constructed along state highway NC 211 in Bolivia, North Carolina, USA, and monitored for 12 months. Thirty-seven of the 39 monitored rain events exfiltrated into underlying soils, resulting in no appreciable overflow or underdrain volume. The bioswale completely exfiltrated a storm event of 86.1 mm. The one event to have underdrain-only flow was 4.8 mm. The largest and third-largest rainfall depth events (82.6 and 146 mm, respectively) had a large percentage (85%) of volume exfiltrated, but also had appreciable overflow and underdrain volumes exiting the bioswale, resulting in no peak flow mitigation. Overall, this bioswale design was able to capture and manage storms larger than the design storm (38 mm), showing the positive hydrologic performance that can be achieved by this bioswale. The high treatment capabilities were likely due to the high infiltration rate of the media and the underlying soil, longer forebay underlain with media, gravel detention layer with an underdrain, and shallow slope.