In this study, PMMA/SiO2 composites were fabricated with monodispersed SiO2 and PMMA using four distinct methods—physical blending, in situ polymerization, random copolymerization, and block copolymerization—to investigate the composites’ thermal, mechanical, and optical properties. In the physical blending approach, SiO2 nanoparticles were dispersed in a PMMA solution, while during in situ polymerization, silica nanoparticles were incorporated during the synthesis of PMMA/SiO2 composites. 3-methacryloxypropyltrimethoxysilane (MPS) was modified on the SiO2 surface to introduce the reactive double bonds. The MPS@SiO2 was either random- or block-copolymerized with PMMA through RAFT polymerization. The PMMA/SiO2 composites prepared via these different methods were characterized using FTIR, TGA, and DSC to determine their chemical structures, thermal degradation temperatures, and glass transition temperatures, respectively. Scanning electron microscopy (SEM) was employed to observe the microstructures and dispersion of the composites. This comprehensive analysis revealed that the PMMA/SiO2 composites prepared via block copolymerization exhibited thermal stability at temperatures between 200 and 300 °C. Additionally, they demonstrated excellent transparency (86%) and scratch resistance (≥6H) while maintaining mechanical strength, suggesting their potential application in thermal insulation materials.
11 September 2017 in BMC Musculoskeletal Disorders
Burst fracture is a common thoracolumbar injury that is treated using posterior pedicle instrumentation and fusion combined with transpedicular intracorporeal grafting after reduction. In this study, we compared the outcome of these two techniques by using radiologic imaging and functional outcome. Sixty-one patients with acute thoracolumbar burst fracture were operated with kyphoplasty (n = 31) or vertebroplasty (n = 30) and retrospectively reviewed in our institution between 2011 and 2014. All 61 patients underwent surgery within 5 days after admission to the hospital and then followed-up for 12 to 24 months after surgery. Significant improvement was found in the anterior vertebral height (92 ± 8.9% in the kyphoplasty group, 85.6 ± 7.2% in the vertebroplasty group, p < 0.01) at 1 month post-operatively and (89 ± 7.9% in the kyphoplasty group, 78 ± 6.9% in the vertebroplasty group, p < 0.01) at the 24-month follow-up. Significant improvement was also observed in the kyphotic angle (1.2 ± 0.5° in the kyphoplasty group, 10.5 ± 1.2° in the vertebroplasty group, p < 0.01) at 1 month post-operatively and (5.4 ± 1.2° in the kyphoplasty group, 11.5 ± 8.5° in the vertebroplasty group, p < 0.01) at the 24-month follow-up. Both operations led to significant improvement of the patients’ pain and the Oswestry disability index (p < 0.01). Cement leakage was noted in 29% of patients after kyphoplasty and 77% of patients after vertebroplasty (p < 0.01). Only one implant failure (3.3%), which required further surgical intervention, was reported in the vertebroplasty group. Reduction with additional balloon at the fractured site is better than indirect reduction only by posterior instrumentation. The better reduction of kyphotic angle and the lower cement leakage rate in the kyphoplasty group indicate that additional balloon kyphoplasty is safe and effective for acute thoracolumbar burst fracture.
22 August 2022 in European Journal of Orthopaedic Surgery & Traumatology
Routine implant removal after fracture healing remains controversial. However, it has been suggested that implant removal should be performed in cases of joint impingement, painful scar adhesion, and implant malposition. Entrance selection is relatively critical in patients with poor soft tissue conditions or sloughing coverage. We propose an innovative technique using endoscopy. Consecutive surgeries of endoscopic implant removal performed between 2005 and 2016 by a single experienced arthroscopic surgeon were included. Overall, 73 patients were enrolled; 44 were not eligible for inclusion and were excluded from the study. Twenty-nine patients, including 32 surgical sites, were included. Twenty-four plates and 166 screws were removed using this technique. There were five complications during the follow-up period (range, 0.5 to 104 months; mean, 8.8), including one broken screw, one persistent knee joint contracture, and three wound dehiscence. There were no infections or neurovascular injuries. Implant removal using endoscopy is a minimally invasive surgery that ensures that the screw axis does not strip, and treats the intra-articular pathology concomitantly. This innovative technique may be considered as an alternative to the traditional open method in cases with good surgical indications.
2 February 2026 in Archives of orthopaedic and trauma surgery
Introduction Minimally invasive plate osteosynthesis (MIPO) has become an established method for treating humeral shaft fractures; however, achieving accurate intraoperative rotational alignment remains challenging. This study describes an intraoperative evaluation technique using combined fluoroscopic and endoscopic assistance to improve the precision and objectivity of rotational correction during MIPO. Materials and methods From September 2019 to June 2023, twenty adult patients with simple transverse or wedge-type midshaft humeral fractures (AO/OTA type A or B) who underwent MIPO fixation were retrospectively reviewed. Demographic data, operative time, intraoperative fluoroscopy time, and postoperative outcomes were analyzed. Rotational difference (RD) between the operated and contralateral arms was measured using computed tomography (CT). Continuous variables between AO type A and B fractures were compared using the Mann–Whitney U test (p < 0.05). Results The mean operative time was 113.5 min, and the mean fluoroscopy time was 75.9 s, which was significantly longer in AO type B fractures (p < 0.05). The average RD was 7.4° ± 4.7° (range, 1.9˚–17.5°). All fractures achieved union, with 18 cases healing within 3–6 months and 2 cases within 9–12 months. Mean angulation was 2.1° (coronal) and 2.0° (sagittal), and mean translation was 1.1 mm (coronal) and 1.3 mm (sagittal). No iatrogenic neurovascular injuries or infections were observed. There were no significant differences between AO type A and type B fractures in union rate or alignment parameters. Conclusions Combined fluoroscopic–endoscopic assistance enables objective intraoperative evaluation of humeral rotational alignment during MIPO without compromising soft-tissue preservation. This technique provides reliable reduction quality and consistent healing outcomes in AO type A and B humeral shaft fractures, representing a practical refinement of standard MIPO principles.
19 May 2025 in European Journal of Orthopaedic Surgery & Traumatology
Purpose Simultaneous ipsilateral sacroiliac joint (SIJ) injury and acetabular fracture are relatively common. Inadequate SIJ reduction may compromise the anatomical alignment of associated acetabular fractures. However, the optimal surgical approach for managing both injuries remains uncertain. In this study, we aimed to compare the efficacy of pelvic ring injury reduction using either the lateral window or the pararectus approach and to analyze associated radiological outcomes in patients with concurrent SIJ injury and acetabular fracture. Methods This retrospective study included 44 patients who underwent open reduction and internal fixation (ORIF) for SIJ injury. Patients were divided into two groups based on the surgical approach: L group (lateral window of the ilioinguinal approach) and P group (pararectus approach). A subgroup of patients with simultaneous ipsilateral SIJ injury and acetabular fracture was selected for comparative analysis using postoperative computed tomography (CT) to assess SIJ reduction and acetabular fracture alignment. Results Improvements in SIJ distance on axial and coronal CT planes were observed in both groups, with greater reductions observed in the P group. Among patients with combined injuries, the P group demonstrated significantly improved SIJ reduction in the coronal plane (P = 0.008), which was associated with smaller residual fracture gaps and articular step-offs in the axial, coronal, and sagittal planes. Conclusion When ORIF is indicated for SIJ injury, the pararectus approach may offer enhanced SIJ reduction in the coronal plane. This technique is also associated with improved acetabular fracture alignment in patients with simultaneous ipsilateral injuries.