Virus-like particles (VLPs) are highly immunogenic and versatile subunit vaccines composed of multimeric viral proteins that mimic the whole virus but lack genetic material. Due to the lack of infectivity, VLPs are being developed as safe and effective vaccines against various infectious diseases. In this study, we generated a chimeric VLP-based COVID-19 vaccine stably produced by HEK293T cells. The chimeric VLPs contain the influenza virus A matrix (M1) proteins and the SARS-CoV-2 Wuhan strain spike (S) proteins with a deletion of the polybasic furin cleavage motif and a replacement of the transmembrane and cytoplasmic tail with that of the influenza virus hemagglutinin (HA). These resulting chimeric S-M1 VLPs, displaying S and M1, were observed to be enveloped particles that are heterogeneous in shape and size. The intramuscular vaccination of BALB/c mice in a prime-boost regimen elicited high titers of S-specific IgG and neutralizing antibodies. After immunization and a challenge with SARS-CoV-2 in K18-hACE2 mice, the S-M1 VLP vaccination resulted in a drastic reduction in viremia, as well as a decreased viral load in the lungs and improved survival rates compared to the control mice. Balanced Th1 and Th2 responses of activated S-specific T-cells were observed. Moderate degrees of inflammation and viral RNA in the lungs and brains were observed in the vaccinated group; however, brain lesion scores were less than in the PBS control. Overall, we demonstrate the immunogenicity of a chimeric VLP-based COVID-19 vaccine which confers strong protection against SARS-CoV-2 viremia in mice.
Wastewater surveillance is considered a promising approach for COVID-19 surveillance in communities. In this study, we collected wastewater samples between November 2020 and February 2022 from twenty-three sites in the Bangkok Metropolitan Region to detect the presence of SARS-CoV-2 and its variants for comparison to standard clinical sampling. A total of 215 wastewater samples were collected and tested for SARS-CoV-2 RNA by real-time PCR with three targeted genes (N, E, and ORF1ab); 102 samples were positive (42.5%). The SARS-CoV-2 variants were determined by a multiplex PCR MassARRAY assay to distinguish four SARS-CoV-2 variants, including Alpha, Beta, Delta, and Omicron. Multiple variants of Alpha–Delta and Delta–Omicron were detected in the wastewater samples in July 2021 and January 2022, respectively. These wastewater variant results mirrored the country data from clinical specimens deposited in GISAID. Our results demonstrated that wastewater surveillance using multiple signature mutation sites for SARS-CoV-2 variant detection is an appropriate strategy to monitor the presence of SARS-CoV-2 variants in the community at a low cost and with rapid turn-around time. However, it is essential to note that sequencing surveillance of wastewater samples should be considered complementary to whole genome sequencing of clinical samples to detect novel variants.
In 2023, Nepal faced its second largest dengue outbreak ever, following a record-breaking number of dengue cases in 2022, characterized by the expansion of infections into areas of higher altitudes. However, the characteristics of the 2023 circulating dengue virus (DENV) and the vector density remain poorly understood. Therefore, we performed DENV serotyping, clinical and laboratory assessment, and entomological analysis of the 2023 outbreak in central Nepal. A total of 396 fever cases in Dhading hospital suspected of being DENV positive were enrolled, and blood samples were collected and tested by different techniques including PCR. Of these, 278 (70.2%) had confirmed DENV infection. Multiple serotypes (DENV-1, -2, and -3) were detected. DENV-2 (97.5%) re-emerged after six years in Dhading while DENV-3 was identified for the first time. Dengue inpatients had significantly higher frequency of anorexia, myalgia, rash, diarrhea, nausea, vomiting, abdominal pain, and thrombocytopenia (p < 0.05). In this area, Aedes mosquitoes largely predominated (90.7%) with the majority being A. aegypti (60.7%). We also found high levels of Aedes index (20.0%) and container index (16.7%). We confirmed multiple DENV serotype circulation with serotype re-emergence and new serotype introduction, and high vector density in 2023. These findings call for the urgent initiation and scaling up of DENV molecular surveillance in human and mosquito populations for dengue control and prevention in Nepal.
: Here, we describe the development of the in-house anti-Zika virus (ZIKV) IgM antibody capture ELISA (in-house ZIKV IgM ELISA) for the detection and diagnosis of acute ZIKV infections. We compared the in-house ZIKV IgM ELISA assay performance against two commercial kits, Euroimmun ZIKV IgM and InBios 2.0 ZIKV IgM ELISA. We tested the assays’ ability to detect anti-ZIKV IgM using a well-defined serum sample panel. This panel included 80 ZIKV negative samples (20 negative, 20 found to be primary dengue virus [DENV][ infections, 20 secondary DENV infections, and 20 Japanese encephalitis virus [JEV] infections) and 67 ZIKV reverse transcriptase–polymerase chain reaction–positive acute serum samples. The OD values were calculated to enzyme immunoassay (EIA) unts by comparing them to weak positive controls. The results demonstrated the high sensitivity (88.06%) and specificity (90.00%) of our in-house ZIKV IgM ELISA and its 89.12% overall percentage agreement. The kappa values were deemed to be within excellent range and comparable to the InBios ZIKV IgM ELISA. Some cross-reactivity was observed among secondary DENV and JEV samples, and to a much lower extent, among primary DENV samples. These data indicate that our in-house ZIKV IgM ELISA is a reliable assay for the detection of anti-ZIKV IgM antibodies in serum.
14 December 2020 in The American Journal of Tropical Medicine and Hygiene
Dengue is a re-emerging global public health problem, the most common arbovirus causing human disease in the world, and a major cause of hospitalization in endemic countries causing significant economic burden. Data were analyzed from passive surveillance of hospital-attended dengue cases from 2002 to 2018 at Phramongkutklao Hospital (PMKH) located in Bangkok, Thailand, and Kamphaeng Phet Provincial Hospital (KPPH) located in the lower northern region of Thailand. At PMKH, serotype 1 proved to be the most common strain of the virus, whereas at KPPH, serotypes 1, 2, and 3 were the most common strains from 2006 to 2008, 2009 to 2012, and 2013 to 2015, respectively. The 11–17 years age-group made up the largest proportion of patients impacted by dengue illnesses during the study period at both sites. At KPPH, dengue virus (DENV)-3 was responsible for most cases of dengue fever (DF), whereas it was DENV-1 at PMKH. In cases where dengue hemorrhagic fever was the clinical diagnosis, DENV-2 was the predominant serotype at KPPH, whereas at PMKH, it was DENV-1. The overall disease prevalence remained consistent across the two study sites with DF being the predominant clinical diagnosis as the result of an acute secondary dengue infection, representing 40.7% of overall cases at KPPH and 56.8% at PMKH. The differences seen between these sites could be a result of climate change increasing the length of dengue season and shifts in migration patterns of these populations from rural to urban areas and vice versa.