Xin Lu

Prof. Xin Lu


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
Seyed Ataollah NaghaviSeyed Ataollah Naghavi
Seyed Ataollah Naghavi
MTMaryam Tamaddon
Maryam Tamaddon
AMArsalan Marghoub
Arsalan Marghoub
KWKatherine Wang
Katherine Wang
BBBehzad Bahrami Babamiri
Behzad Bahrami Babamiri
Chaozong LiuChaozong Liu
Chaozong Liu
Additive manufacturing has been used to develop a variety of scaffold designs for clinical and industrial applications. Mechanical properties (i.e., compression, tension, bending, and torsion response) of these scaffolds are significantly important for load-bearing orthopaedic implants. In this study, we designed and additively manufactured porous metallic biomaterials based on two different types of triply periodic minimal surface structures (i.e., gyroid and diamond) that mimic the mechanical properties of bone, such as porosity, stiffness, and strength. Physical and mechanical properties, including compressive, tensile, bending, and torsional stiffness and strength of the developed scaffolds, were then characterised experimentally and numerically using finite element method. Sheet thickness was constant at 300 μm, and the unit cell size was varied to generate different pore sizes and porosities. Gyroid scaffolds had a pore size in the range of 600–1200 μm and a porosity in the range of 54–72%, respectively. Corresponding values for the diamond were 900–1500 μm and 56–70%. Both structure types were validated experimentally, and a wide range of mechanical properties (including stiffness and yield strength) were predicted using the finite element method. The stiffness and strength of both structures are comparable to that of cortical bone, hence reducing the risks of scaffold failure. The results demonstrate that the developed scaffolds mimic the physical and mechanical properties of cortical bone and can be suitable for bone replacement and orthopaedic implants. However, an optimal design should be chosen based on specific performance requirements.
1

1 December 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
WXW. Xu
W. Xu
XLXin Lu
Xin Lu
LWL.N. Wang
L.N. Wang
ZSZ.M. Shi
Z.M. Shi
SLS.M. Lv
S.M. Lv
XQX.H. Qu
X.H. Qu

15 March 2018 in Metals
Verified
Journal Article
Open access
PDF file
WXWeo Xi
Weo Xi
XLXin Lu
Xin Lu
BZBing Zhang
Bing Zhang
LCLiu Chengcheng
Liu Chengcheng
Shaomin LvShaomin Lv
Shaomin Lv
Xuanhui QuXuanhui Qu
Xuanhui Qu
Porous binary Ti-10Mo alloys were prepared using non-spherical titanium, molybdenum powders by the powder metallurgy (PM) space holder technique. Based on the three-dimensional analysis of porosity characteristics, a detailed assessment of the effects of porosity on mechanical properties and corrosion resistances in phosphate-buffered saline (PBS) was carried out. For comparison, PM-fabricated CP-Ti with 50.5% porosity sintered at 1200 °C for 2 h and dense Ti-10Mo alloy sintered at 1450 °C for 2 h (relative density is 97.2% and porosity is 2.8%) were studied simultaneously. The results show that with the space-holder volume contents rising from 63 to 79%, the open porosity and average pore size (d50) increase remarkably, while the pore size distribution (d10–d90) tends to be stable at about 100 μm. The average pore sizes (d50) of porous Ti-10Mo alloy can be controlled in the range of 70–380 μm. The PM-fabricated porous Ti-10Mo alloy can achieve a wide range of mechanical properties, with yield compression strength of 248.2–76.9 MPa, and elastic modulus of 6.4–1.7 GPa. In addition, the yield compression strength and the elastic modulus meet the linear regression and exponential formula, respectively. With the porosity of Ti-10Mo alloy increasing from 2.8 to 66.9%, the corrosion rate rises exponentially from 1.6 g/m2·day to 17.1 g/m2·day. In comparison to CP Ti with nearly the same porosity, Ti-10Mo alloy shows significantly higher corrosion resistance. As a result, the relationships between porosity and mechanical properties, corrosion resistances of Ti-10Mo alloys were established, which can be used as a design reference in material selection for orthopedic applications.

1 December 2019 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
WXWei Xu
Wei Xu
JTJingjing Tian
Jingjing Tian
ZLZhuo Liu
Zhuo Liu
XLXin Lu
Xin Lu
MHMuhammad Dilawer Hayat
Muhammad Dilawer Hayat
Cuie WenCuie Wen
Cuie Wen

30 January 2019 in Science China Materials
Verified
Journal Article
Open access
PDF file
WXWei Xu
Wei Xu
ZLZhuo Liu
Zhuo Liu
XLXin Lu
Xin Lu
JTJingjing Tian
Jingjing Tian
GCGang Chen
Gang Chen
Cuie WenCuie Wen
Cuie Wen
Porous Ti-10Mo alloys were fabricated by powder metallurgy using a space-holder method. The pore characteristics, microstructure, mechanical properties, in vitro biocompatibility, and in vivo osseointegration of the fabricated alloys were systematically investigated. The results show that with different weight ratios of the space-holder (NH4 HCO3) added, all of the porous Ti-10Mo alloys sintered at 1,300°C exhibited a typical Widmanstätten microstructure. The porosity and average pore size of the porous structures can be controlled in the range of 50.8%–66.9% and 70.1–381.4 μm, respectively. The Ti-10Mo alloy with 63.4% porosity exhibited the most suitable mechanical properties for implant applications with an elastic modulus of 2.9 GPa and a compressive yield strength of 127.5 MPa. In vitro, the alloyconditioned medium showed no deleterious effect on the cell proliferation. The cell viability in this medium was higher than that of the reference group, suggesting non-toxicity and good biological characteristics of the alloy specimens. In vivo, after eight weeks’ implantation, new bone tissue formed surrounding the alloy implants, and no noticeable inflammation was observed at the implantation site. The bone bonding strength of the porous Ti-10Mo alloy increased over time from 46.6 N at two weeks to 176.4 N at eight weeks. Suitable mechanical properties together with excellent biocompatibility in vitro and osteointegration in vivo make the porous Ti-10Mo fabricated by powder metallurgy an attractive orthopedic implant alloy. 本文中, 我们以元素粉末为原料, 采用粉末冶金造孔剂法制备了多孔Ti-10Mo合金, 系统探讨了所制备的多孔Ti-10Mo合金的孔隙特 征、显微组织、力学性能、体外生物相容性及体内骨整合能力. 结果表明, 随着造孔剂含量的增加(碳酸氢铵),在1300°C下烧结的多孔Ti- 10Mo合金均由魏氏体组织组成. 所制备的Ti-10Mo合金的孔隙率与平均孔尺寸能够分别控制在50.8%–66.9%与70.1–381.4 μm. 孔隙率为 63.4%的Ti-10Mo合金具有最适合植入应用的力学性能, 其弹性模量为2.9 GPa, 抗压屈服强度为127.5 MPa. 在体外, Ti-10Mo合金浸提液 对细胞增殖没有不良影响. 细胞在浸提液中的存活率高于对照组, 表明合金无毒性并且具有良好的生物学特征. 在体内, 植入8周后合金周 围被新生骨包围, 并且植入部分未见明显炎症. 随着植入时间由2周增加到8周, 多孔Ti-10Mo合金的骨结合强度从46.6 N增加到176.4 N. 适 合的力学性能以及良好的体外生物相容性和体内骨整合性使粉末冶金法制备的多孔Ti-10Mo成为一种具有吸引力的骨科植入合金.

6 July 2022 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
CHChenjin Hou
Chenjin Hou
YLYitong Liu
Yitong Liu
Wei XuWei Xu
Wei Xu
XLXin Lu
Xin Lu
Lijia GuoLijia Guo
Lijia Guo
Cuie WenCuie Wen
Cuie Wen