Ashraf Rasheed

Dr. Ashraf Rasheed


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2016 in Journal of Chromatographic Science
Verified
Journal Article
Closed access
PDF file
ARAshraf Rasheed
Ashraf Rasheed
BABashaer Abbas Al-Phalahy
Bashaer Abbas Al-Phalahy
ASAndreas Seubert
Andreas Seubert
Zwitterionic stationary phases with nearly identical capacities were prepared by graft polymerization of a series of sulfobetaine precursors onto the surface of porous PS/DVB particles. The different spacer lengths are used as an investigative tool for the retention behavior of carboxylic acids; namely malonic, succinic, glutaric and maleic acid. In zwitterionic ion chromatography-hydrophilic interaction liquid chromatography (ZIC-HILIC) separation mode, the retention characteristic of carboxylic acids was examined using sodium acetate/acetonitrile eluents and UV detection. The retention is based on partitioning in reversed as well as in HILIC mode and zwitterionic ion exchange resulting in a mixed separation mode for the carboxylic acids. This ion exchange behavior has never been observed before for sulfobetaine-based zwitterionic stationary phases.

14 June 2017 in Current Pharmaceutical Analysis
Verified
Journal Article
Closed access
ASAndreas Seubert
Andreas Seubert
ARAshraf Rasheed
Ashraf Rasheed
Background: Despite the numerous studies about ZIC and ZIC-HILIC retention modes, the mechanism has not been fully investigated and there are no detailed mechanistic concepts in the literature. Some of the pharmaceutical compounds can act as a strong chelator for multiple charged metal ions of biological importance. Trifluoperazine hydrochloride (TFPH) is a strong chelator for multiple charged metal ions of biological importance (Pd2+, Pt4+, V5+) and other metals. It will be interesting to see if the metal–complexes are also separated using the zwitterionic stationary phase. Methods and Result: The study of the influence of pH and eluent concentration of metal-TFPH complexes selectivity should give a clue about the properties of the individual zwitterionic stationary phases and thus about the separation mechanism. The retention factors of Pt(IV)-TFPH, Pd(II)-TFPH and V(V)-TFPH complexes decreased with an increasing buffer concentration. The ZIC5 stationary phase as well as the examined commercial stationary phases ZIC-HILIC and ZIC-pHILIC exhibit the same behavior. The retention of the TFPH-Pt(IV), TFPH-Pd(II) and TFPH-V(V) complexes with their positive charge decreased on ZIC5, ZIC-HILIC and ZIC-pHILIC columns when the pH increased in the range between 3 to 6. The results of variations of buffer concentration and mobile phase pH show that metal- TFPH complexes can be separated based cation-exchange interactions and electrostatic interaction between the stationary phase and analyte. Conclusion: The current study confirmed the ability of ZIC-HILIC stationary phases to separate metalcomplexes. It could be demonstrated that metal-TFPH separations on zwitterionic stationary phase are mainly driven by a cation exchange mechanism.

4 April 2016 in Current Chromatography
Verified
Journal Article
Closed access
ARAshraf Rasheed
Ashraf Rasheed
ASAndreas Seubert
Andreas Seubert
Background: Sulfobetaine zwitterionic stationary phases are offering various retention modes, but the influence of the capacity has never been investigated systematically. Objective: The capacity dependence of the retention and selectivity in zwitterionic ion chromatography mode has been investigated for common UV absorbing anions. Methods: Stationary phases with variable distances between the charged groups (one to four methylen groups) were prepared with capacities from 296 to 790 (one and two methylene groups as charge separator) or from 212 to 298 µeq g-1 (three and four methylene groups) by grafting polymerization on highly porous divinylbenzene polymers. The different spacer lengths and capacities are used as an investigative tool for the retention behavior of the anions nitrate, nitrite, bromide, iodide and thiocyanate. The separation mechanism is explored by varying eluent ionic strength and pH. Results: Remarkably, an increasing capacity leads depending on the charge distance to an increase for two and three methylen groups, decrease for four or no significant change in the retention times of inorganic anions for one methylene group charge distance. No significant change of selectivity occurred in investigated range of capacities. It should be noted that the higher capacity of the exchanger with two methylene groups between the oppositely charged groups exhibit a different separation behavior for inorganic anions in comparison to a previous study. Conclusions: The capacity plays in zwitterionic ion chromatography an important role for the retention behavior. The changes in retention behavior are depending on the spacer length between the charged groups.

17 August 2020 in Current Pharmaceutical Analysis
Verified
Journal Article
Closed access
PDF file
FAFatma H. Abdulla
Fatma H. Abdulla
ARAshraf Rasheed
Ashraf Rasheed
Background: Esculin (ESCN) is used in the pharmaceutical industry with intravenous effect, stimulant and anti-inflammatory capillaries, like vitamin P. It is a significant component of many anti-inflammatory remedies such as esqusan, esflazid and anavenol [14]. It is also found in numerous other remedies available in the market such as proctosone, anustat, and ariproct.Objective: To determine experimental conditions, to elucidate retention behavior of esculin in HILIC mode. Moreover, to suggest new ways to separate and determinate esculin in ointments.Methods: Two hydrophilic columns were obtained by attaching molecules of sulfobetaine to polystyrene- divinylbenzene particles were studied for chromatographic separation of esculin. The various lengths of the chain are used as an investigative instrument for esculin retention conduct. The change of ACN percentage, buffer concentrations and pH of mobile phase in order to study the retention conduct of esculin.Results: A mixed mode hydrophilic interaction and ion exchange is the separation mechanism of esculin. A calibration graph was created for two columns. The concentration range was 8-1200 ng.ml-1, LOD 2.33 and 1.40, RSD% 0.31-1.02, , LOQ 7.07 and 4.25 ng.ml-1, Erel% 0.83 ± 0.68 and 0.545 ± 0.45, Recovery% 100.86 ± 0.68 and 1054 ± 0.45.Conclusion: The findings of the current study introduced new ZIC-HILIC methods for the separation and quantitation of esculin.

16 September 2022 in Current Pharmaceutical Analysis
Verified
Journal Article
Closed access
PDF file
ARAshraf Rasheed
Ashraf Rasheed
AWAli Amer Waheb
Ali Amer Waheb
MHMohammed Jasim M. Hassan
Mohammed Jasim M. Hassan
Background: Non-steroidal anti-inflammatory drugs (NSAIDs) are widely used worldwide for their analgesic, anti-inflammatory, and antipyretic properties. Objective: The article highlights the development of zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) methods to quantify three NSAIDs as active ingredients in pharmaceutical formulations simultaneously. Method: For NSAIDs analysis, two homemade ZIC-HILIC stationary phases were carried out by adding sulfobetaine monomers to polystyrene-divinylbenzene particles. The methods were developed by examining the effect of HILIC mode parameters like the kind of organic modifier (methanol or acetonitrile), acetonitrile content, pH and concentration of the acetate buffer in the eluent. Results: The experimental data exhibit the predominant mechanism of NSAIDs with two ZICHILIC stationary phases. The different chain lengths in the two ZIC-HILIC stationary phases are employed to investigate NSAIDs retention behaviour. The strategies were evaluated for their specificity, linearity, accuracy, and precision. The linear ranges were 0.01-5.0, 0.05-17.5 and 0.12-13.5 μg ml-1, LOD 0.005. 0.015 and 0.046 μg ml-1 and LOQ 0.015, 0.045 and 0.139 μg ml-1 for nimesulide, tenoxicam and diclofenac, respectively. Conclusion: They represent interactions with three NSAIDs, ZIC-HILIC columns, and mobile phase in a mixed-mode of hydrophilic and hydrophobic interactions. In contrast to the ZICHILIC- 1 stationary phase with a shorter chain length, the ZIC-HILIC-4 stationary phase with a longer chain length exhibited a longer retention time, lower detection and limit of quantitation for three NSAIDs.The verification findings demonstrate the suitability of the proposed ZIC-HILIC methods for quantifying NSAIDs in pharmaceutical formulations.

1 January 2016 in Asian Journal of Chemistry
Verified
Journal Article
Open access
BABashaer Abbas Al-Phalahy
Bashaer Abbas Al-Phalahy
YMYasmeen H. Muhamad
Yasmeen H. Muhamad
ARAshraf Rasheed
Ashraf Rasheed