Bujun Yu

Dr. Bujun Yu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WCWenhua Cai
Wenhua Cai
BYBujun Yu
Bujun Yu
Sakdirat KaewunruenSakdirat Kaewunruen
Sakdirat Kaewunruen
In this study, a series of shaking table tests of a ten storey concrete suspended structure equipped with viscous dampers were carried out to evaluate the dynamic responses and vibration damping performance of suspended structures. The effects of link types between the primary structure and suspended floors and different seismic excitations on the response of suspended structure models was verified. The responses include the damping ratio, the frequency, maximum relative displacements, accelerations and maximum strains of the suspended structures. Test results showed that the damping ratio and the frequency of suspended structures installed with dampers (called damping suspended structure) are adjusted compared with a conventional suspended structure with rigid-bar links (conventional suspended structure). Maximum relative displacements of the primary structure of the damping suspended structure were distinctly smaller than those of the conventional suspended structure. However, the maximum relative displacement between the primary structure and the suspended floors of the damping suspended structure was significantly larger than that of the conventional structure, indicating that the swing of the suspended floor can help dissipate seismic energy. The peak acceleration and acceleration amplification factors of the damping suspended structure were less than the conventional suspended structure. Moreover, the peak acceleration response of the damping suspended structure was slightly behind the conventional suspended structure. The damping suspended structure certainly had a considerable and stable reduction for strain response, and the maximum strain response was decreased by 42.3%–72.7% for the damping suspended structure compared with the conventional suspended structure.

10 April 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
WCWenhua Cai
Wenhua Cai
BYBujun Yu
Bujun Yu
JZJun Zhang
Jun Zhang
The original anchoring performance is not good enough, and the failure mode is not ideal. This paper improves and redesigns the clip anchor for CFRP tendon. The improved anchor has two-piece clips, eliminates the difference in taper angle between the anchor cup and the clip, and adjusts the slit on the clip. And then, through the uniaxial tensile static load tests of the anchorage assemblies, the failure modes and load-slip behaviour of CFRP tendon in the loading process are studied. The results showed that the improved anchor for CFRP tendon had a good anchoring performance, the CFRP tendons destructed outside the anchor that achieved an ideal breaking form. The treatment on the inner wall of the clip and the use of aluminum sheets can effectively reduce the slip of the anchor and enhance the anchoring performance. The research work done for clip anchorages of CFRP tendon had provided reliable basis for the wider application of CFRP tendons in civil engineering.