Objective To investigate intrarater reliability and concurrent and construct validity of muscle strength, balance, and functional mobility measures in individuals with noncongenital myotonic dystrophy type 1 (DM1). Methods Seventy-eight adults with noncongenital DM1 participated in visit 1, and 73 of the them participated in visit 2 separated by 1 to 2 weeks. The assessments consisted of muscle strength tests with handheld dynamometry (HHD) and stationary dynamometry in the lower limb. The balance tests consisted of the step test, Timed Up and Go test, feet-together stance, tandem stance, 1-leg stance, and modified Clinical Test of Sensory Integration and Balance on a balance platform. The functional mobility tests consisted of the 10-m walk test (10mWT) and 10-times Sit-to-Stand test. Results The HHD and stationary dynamometry had sufficient intrarater reliability for most muscle groups on a group (SEM% ≤15%) and individual (minimal detectable difference [MDD95%] ≤30%) level, but the HHD was most reliable. Stationary dynamometry measured a higher torque than HHD for all extensor muscles, but for single individuals, none of the devices were favored. Overall, intrarater reliability and validity were sufficient only for the dynamic balance tests, not the static balance tests. Both functional mobility tests were sufficiently reliable and valid, but the 10mWT was most reliable. Conclusion Overall, HHD is recommended as a reliable and valid tool for single individuals and for flexor muscles on a group level. For balance assessments, the dynamic balance tests are recommended as the most valid and reliable balance tests. Both functional mobility tests are recommended for valid and reliable outcomes, but the 10mWT was superior for reliability.
Myotonic dystrophy type 1 (DM1) is an autosomal dominant multisystem disorder mainly characterized by gradual muscle loss, weakness, and delayed relaxation after muscle contraction. It is caused by an expanded CTG repeat in the 3′ UTR of DMPK, which is transcribed into a toxic gain-of-function mRNA that affects the splicing of a range of other genes. The repeat is unstable, with a bias towards expansions both in somatic cells and in the germline, which results in a tendency for earlier onset with each generation, as longer repeat lengths generally correlate with earlier onset. Previous studies have found hypermethylation in the regions flanking the repeat in congenital onset DM1 and in some patients with non-congenital DM1. We used pyrosequencing to investigate blood methylation levels in 68 patients with non-congenital DM1, compare the methylation levels between the blood and muscle, and assess whether methylation levels change over time in the blood. We found higher methylation levels in the blood of DM1 patients than in healthy controls and especially in the patients who had inherited the disease allele maternally. The methylation levels remained relatively stable over time and are a strong biomarker of the disease, as well as of the maternal inheritance of the disease.
Background: Charcot–Marie–Tooth (CMT) disease is a hereditary neuropathy associated with impaired walking capacity. Some patients are too weak in the lower extremity muscles to walk at gravity with sufficient intensity or duration to gain benefit.Aim: The aim was to investigate the effect of aerobic anti‐gravity exercise in weak patients with CMT 1A and X.Methods: Five adult patients performed moderate‐intensity aerobic anti‐gravity exercise 3/week for 10 weeks.Results: There was a significant positive difference in Berg balance scale and postural stability test between test occasions, and walking distance in the 6‐min walk test trended to increase.Conclusions: The study indicates that the anti‐gravity treadmill training of patients with CMT should be pursued in larger CMT cohorts.
Objective: As myotonic dystrophy type 1(DM1) evolves slowly and interventional trials often have a short duration, responsive outcomes in DM1 are needed. The objective of this study was to determine the responsiveness of muscle strength, balance, and functional mobility measurements after a 1-year follow-up period in individuals with DM1. Methods: Sixty-three adults with noncongenital DM1 completed the following assessments at baseline and at 1-year follow-up: Handheld dynamometry (lower limbs), stationary dynamometry (lower limbs), step test, timed-up-and-go test (TUG), modified clinical test of sensory integration and balance (mCTSIB), feet-together stance, tandem stance, one-leg stance, 10-meter walk test, and sit-to-stand test. Results: Change was captured by stationary dynamometry (proximal flexor and extensor muscles), handheld dynamometry (proximal flexor and distal extensor muscles), TUG, and mCTSIB (P <= 0.04). Ceiling or floor effects were shown for most static balance tests. Interpretation: Overall, adequate responsiveness was shown for both muscle strength dynamometers, TUG and mCTSIB. These outcomes are therefore likely candidate endpoints for clinical trials lasting 1 year. Most static balance tests are not responsive and not recommended in a heterogeneous DM1 population.