Michel Bernier

Dr. Michel Bernier


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2011 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
PEParham Eslami-Nejad
Parham Eslami-Nejad
MBMichel Bernier
Michel Bernier

3 October 2014 in HVAC&R Research
Verified
Journal Article
Closed access
ASAli Salim Shirazi
Ali Salim Shirazi
MBMichel Bernier
Michel Bernier
This article reports on the design and construction of a small-scale laboratory tank to study transient heat transfer in innovative ground heat exchangers designs. The tank is 1.35 m high and has a diameter of 1.4 m. It is filled with well-characterized laboratory-grade sand and instrumented with precisely positioned thermocouples. Experimental results for a 73-h heat injection period followed by a 5-day recovery period for a single U-tube borehole are reported. A comparison is performed against results obtained with an axisymmetric numerical model of the ground surrounding the borehole. It is shown that the agreement between both set of results is very good indicating that accurate experimental data can be obtained with the apparatus.

6 February 2012 in Journal of Building Performance Simulation
Verified
Journal Article
Closed access
SBStephane Bertagnolio
Stephane Bertagnolio
MBMichel Bernier
Michel Bernier
MKMichaël Kummert
Michaël Kummert
The main objective of this article is to establish a set of test cases for analytical verification and inter-model comparison of vertical ground heat exchanger (GHX) models used in building simulation programs. Several test cases are suggested. They range from steady-state heat rejection in a single borehole to varying hourly loads with relatively large yearly thermal imbalance in multiple borehole configurations. The usefulness of the proposed test cases is illustrated with different GHX models. This comparison exercise has shown that analytical one-dimensional (1D) models compare favourably well with three-dimensional (3D) models for relatively short-simulation periods, where axial effects are not significant. Cyclic heat rejection/collection tests proved to be useful to characterize the accuracy and the computational performance of different load aggregation algorithms. Finally, different spatial superposition methods have been compared for various bore field sizes and configurations and various loads.

29 January 2018 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
MAMohammadamin Ahmadfard
Mohammadamin Ahmadfard
MBMichel Bernier
Michel Bernier
The current article proposes modifications to the ASHRAE sizing equation for vertical ground heat exchangers. The proposed method uses the same three pulse approach as the current sizing equation but uses g-functions to calculate the effective ground thermal resistances. One key feature of the iterative methodology is the ability to calculate new g-functions as the geometry morphs during the solution process. Long-term g-functions are evaluated analytically using the finite line source (FLS) solution over borehole segments while so-called short-term g-functions are calculated based on a hybrid analytical/numerical method to account for the borehole thermal capacity. The current article examines three aspects of the proposed methodology. First, it is shown that the time-consuming evaluation of the full g-function curve, typically obtained by temporal superposition, is not necessarily required. Second, the optimum number of borehole segments to obtain an accurate bore field length with reasonable calculation time is examined. The selection of a convergence criteria and its impact on calculation time is also discussed. The excellent agreement between results obtained with the proposed alternative method and the ones obtained from other design software tools confirms the validity of the proposed method. Finally, it is shown that short-term effects can have a relatively significant effect on the calculation of the required borehole length.

12 April 2024 in Energies
Verified
Journal Article
Open access
PDF file
GVGeoffrey Viviescas
Geoffrey Viviescas
MBMichel Bernier
Michel Bernier
An experimental validation of a steady-state model for water-to-water heat pumps is conducted on a 10 kW test bench. The objective of the model is to predict the capacity and the required compressor power, based on the inlet conditions of the secondary fluids in the evaporator and condenser. Detailed manufacturer performance maps based on the AHRI 540-2020 standard are utilized to model the fixed-speed scroll compressor. A new semi-empirical model for the thermostatic expansion valve incorporates condensing temperature effects on superheating prediction. Sub-models for individual components, including detailed representations of the evaporator and condenser, are integrated into a global model, resulting in a set nonlinear equation solved using an equation solver with appropriate guess values. The validation of the model is conducted in an experimental test facility equipped with two precisely controlled secondary fluid loops. The heat pump is instrumented to measure condensation and evaporation pressures, the compressor discharge temperature, compressor power, superheating, and sub-cooling. The results are divided into three sub-sections: the first validates the complete heat pump model by comparing its power consumption and COPs in heating and cooling; the second compares the predicted and measured operational conditions; finally, it is shown how the model can be used to predict the non-operational conditions of the heat pump for specific scenarios.

31 August 2012 in International Journal of Refrigeration
Verified
Journal Article
Closed access
DNDemba Ndiaye
Demba Ndiaye
MBMichel Bernier
Michel Bernier