Background: The identification of neck lymph node (LN) metastases represents a very important issue in the management of patients with differentiated thyroid carcinoma (DTC). To this purpose, in the present study, we used 131I-SPECT/CT as a diagnostic imaging procedure.Methods: A consecutive series of 224 DTC patients with ascertained neck radioiodine-avid foci at131I-SPECT/CT during long-term follow-up was evaluated. All patients had already undergone total thyroidectomy and radioiodine therapy and had been classified as follows: 62 at high risk (H), 64 at low risk (L) and 98 at very low risk (VL).131I-Whole body scan (WBS) followed by SPECT/CT was performed in all cases.Results: In the 224 patients, 449 neck iodine avid foci were ascertained at SPECT/CT, while 322 were evidenced at WBS in 165/224 patients. WBS classified as residues 263/322 foci and as unclear 59/322 foci; among the former foci SPECT/CT correctly characterized 8 LN metastases and 3 physiologic uptakes and among the latter, it pinpointed 26 LN metastases, 18 residues, and 15 physiologic uptakes. SPECT/CT also classified 127 foci occult at WBS as 59 LN metastases and 68 residues. Globally, SPECT/CT identified 93 LN metastases in 59 patients (26 H, 20 L, 13 VL), while WBS evidenced 34 in 25 cases. All 13 VL patients, T1aN0M0, 5 of whom with LN near sub-mandibular glands, had thyroglobulin undetectable or < 2.5 ng/ml. Globally, SPECT/CT obtained an incremental value than WBS in 45.5% of patients, a more correct patient classification changing therapeutic approach in 30.3% of cases and identified WBS false-positive findings in 8% of cases.Conclusions: 131I-SPECT/CT proved to correctly detect and characterize neck LN metastases in DTC patients in long-term follow-up, improving the performance of planar WBS. SPECT/CT routine use is thus suggested; its role is particularly relevant in patients with WBS inconclusive, VL, T1aN0M0 and with undetectable or very low thyroglobulin levels.
Planar scintimammography (SM) acquired with a conventional γ camera has proved a useful complementary tool to mammography (Mx) in breast cancer (BC) diagnosis, but with unsatisfactory sensitivity in small size carcinomas. In this study we assessed the role of planar SM with a high-resolution dedicated breast camera (DBC) in BC diagnosis, comparing the results with those of Mx. A consecutive series of 145 patients scheduled for biopsy for suspected BC underwent Tc-99m tetrofosmin planar SM using a newly developed DBC. Scintigraphic data were compared with Mx findings and correlated to histology. Histopathologic analysis revealed 165 lesions: 143 malignant and 22 benign. SM detected 139/143 carcinomas (overall sensitivity: 97.2%) and was true negative in 19/22 benign lesions (overall specificity: 86.4%). SM sensitivity was 91% in ≤10-mm carcinomas. SM was more accurate than Mx in 42/145 cases (29%), detecting cancer in 9 patients with Mx indeterminate for dense breasts (8/9 tumors were <10 mm), assessing additional tumor foci (all <10 mm) in 5 points with multifocal disease and correctly classifying 28 patients with inconclusive mammographic findings as affected by cancer or by benign disease. Mx was more accurate than SM in 3 patients, in each detecting 1 subcentimeter BC false negative on SM. DBC planar SM seems a highly sensitive diagnostic tool in the detection of BC, even when small in size, and in the assessment of multifocal disease. A wider employment of this procedure is thus suggested, especially in indeterminate or inconclusive mammographic findings to improve sensitivity and specificity of Mx.
Ductal carcinoma in situ (DCIS) is a subtype of breast cancer encountered increasingly in clinical practice because of the widespread use of screening mammography. In the present study, we evaluated the usefulness of breast-specific γ-camera (BSGC) scintigraphy in DCIS identification, describing the scintigraphic findings and their correlation with mammography and histologic subtype. Methods: Thirty-three women, aged 41–81 y, with surgically proven DCIS were retrospectively reviewed. Before surgery, all patients underwent breast scintigraphy using a high-resolution semiconductor-based BSGC, starting 10 min after intravenous injection of 740 MBq of 99mTc-tetrofosmin. All patients had previously undergone mammography. A definitive histologic diagnosis was obtained in all cases after scintigraphy, and the scintigraphic findings were correlated with mammography and histologic subtype. Results: Mammography was positive in 30 of 33 patients (sensitivity, 90.9%), showing calcifications in 22 of 30 (73.3%), masses in 3 of 30 (10%), and masses plus calcifications in the remaining 5 of 30 (16.7%). Scintigraphy was positive in 31 of 33 patients (sensitivity, 93.9%), showing patchy irregular uptake in patients with calcifications and focal uptake in masses; sensitivity was higher in low- to intermediate-grade DCIS than in intermediate/high- and high-grade DCIS (100% vs. 91.3%), but the difference was not statistically significant. Two comedo-type DCIS (one 20-mm intermediate/high-grade and one 15-mm high-grade) with heterogeneously or highly dense breasts at mammography and one papillary low/intermediate-grade DCIS associated with Paget disease were true positive only at scintigraphy. Moreover, scintigraphy better assessed disease extent than did mammography in 5 additional patients. Two comedo-type DCIS (one 6-mm intermediate/high-grade and one 15-mm high-grade) were true positive only at mammography. The difference in sensitivity between scintigraphy and mammography was not statistically significant. The combined use of mammography and scintigraphy achieved 100% sensitivity. Conclusion: BSGC scintigraphy proved to be a highly sensitive diagnostic tool in the detection of DCIS, irrespective of histologic subtype, and with a scintigraphic pattern of uptake that correlated well with mammography findings. In our series, BSGC scintigraphy demonstrated a slightly higher sensitivity than mammography and a better assessment of local disease extent. Thus, BSGC scintigraphy should represent a useful adjunctive tool in breast cancer diagnosis.
131I Single-photon emission computerized tomography/computerized tomography (SPECT/CT) in the management of patients thyroidectomized for differentiated thyroid carcinoma (DTC) was further investigated. Retrospectively, 106 consecutive DTC patients were enrolled at the first radioiodine ablation, 24 at high risk (H), 61 at low risk (L) and 21 at very low risk (VL). 131I whole-body scan (WBS) and SPECT/CT were performed after therapeutic doses using a hybrid dual-head gamma camera. At ablation, SPECT/CT correctly classified 49 metastases in 17/106 patients with a significantly (p < 0.001) more elevated number than WBS which evidenced 32/49 foci in 13/17 cases. In this case, 86/106 patients could be monitored in the follow-up including 13/17 cases with metastases already at post-therapeutic scans. SPECT/CT after radioiodine diagnostic doses more correctly than WBS ascertained disease progression in 4/13 patients, stable disease in other 4/13 cases and disease improvement in the remaining 5/13 cases. Further 13/86 patients with only residues at post-therapeutic scans showed at SPECT/CT 16 neck lymph node (LN) metastases, three unclear and 13 occult at WBS. Significant involvement of some tissue risk factors with metastasis appearance was observed, such as minimal extrathyroid tumor extension and neck LN metastases. These risk factors should be carefully considered in DTC patient follow-up where 131I-SPECT/CT routinely use is suggested as a support tool of WBS.
Hashimoto’s thyroiditis (HT) is often associated with papillary thyroid carcinoma (PC); it is still a matter of controversy whether the behavior of carcinoma is more aggressive or not. During the follow-up, we retrospectively enrolled 97 patients with PC/HT after thyroidectomy without risk factors at the surgery of the primary tumor, such as multifocality/multicentricity, extrathyroid tumor extension, vascular invasion, neck and distant metastases, and aggressive histological variants. HT diagnosis was confirmed by histology and serum thyroid antibodies. Tumor size was ≤10 mm in 64 cases (microcarcinomas); 206 matched PC patients after thyroidectomy without HT and risk factors were enrolled as controls, totaling 122 microcarcinomas. During follow-up, metastases occurred in 15/97 (15.5%) PC/HT cases, eight microcarcinomas, and in 16/206 (7.8%) without HT, eight microcarcinomas (p = 0.04). Considering both PC/HT and PC patients without HT who developed metastases, univariate analysis showed an increased risk of metastases in patients with HT coexistence, OR: 2.17 (95% CI 1.03–4.60) p = 0.043. Disease-free survival (DFS) was significantly (p = 0.0253) shorter in PC/HT than in the controls. The present study seems to demonstrate that HT is not a cancer protective factor in PC patients given the less favorable outcomes and significantly shorter DFS. HT may also represent an independent recurrence predictor without other risk factors.