The interest of the scientific community for ultrasound techniques has increased in recent years due to its wide range of applications. A continuous effort of researchers and industries has been made in order to improve and increase the applicability of non-destructive evaluations (NDE). In this context, the monitoring of manufacturing processes, such as the grinding process, arises. This work proposes a novel technique of ultrasound monitoring (chirp-through-transmission) through low-cost piezoelectric diaphragms and digital signal processing. The proposed technique was applied to the monitoring of material removal during the grinding process. The technique is based on changes in ultrasonic waves when propagated through the material under study, with the difference that this technique does not use traditional parameters of ultrasonic techniques but digital signal processing (RMS and Counts). Furthermore, the novelty of the proposed technique is also the use of low-cost piezoelectric diaphragms in the emission and reception of ultrasonic waves, enabling the implementation of a low-cost monitoring system. The results show that the monitoring technique proposed in this work, when used in conjunction with the frequency band selection, is sensitive to the material removal in the grinding process and therefore presents an advance for monitoring the grinding processes.
The 3D printing process deals with the manufacture of parts by adding layers of material onto a heated printing bed. Electret microphones are widely used as low-cost and precise measuring devices. However, its response was negatively affected by higher temperatures due to the field effect transistor utilized in its construction. The Pencil Lead Break (PLB) method is a standardized artificial acoustic emission source utilized for the evaluation of sensors response. The present work aimed to study the electret microphone response for 3D printing monitoring and to evaluate the efficiency of a proposed housing to reduce the printing bed temperature’s influence on the electret microphone’s response. The microphone housing was 3D-printed utilizing ABS filament; its geometry was designed with the purpose of separating the sensor from the heated bed and creating an acoustic shell. Then, PLB tests were performed, and the raw signal was collected from housed and non-housed microphones at 5 MHz sampling frequency. The sensors were tested under three temperatures of the printer bed: at 25 °C (ambient), at 65 °C (operating temperature), and, finally, after the temperature of the table was naturally stabilized from 65 °C to 25 °C. The signals were investigated in the time and frequency domain. The results showed that the housing impacts the microphone’s response positively when operating at 25 °C, where the signals presented higher amplitudes in both domains. However, the response obtained by the housed sensor was considerably attenuated at 65 °C. Furthermore, the signals collected at 25 °C after exposing the housed microphone to heat demonstrated a “greenhouse effect”, keeping the sensor at higher temperatures for an extended period. It can be concluded that the proposed housing failed in reducing the temperature effects in the sensor’s response. However, these effects were shown to be significant and the need for an alternative method to attenuate them was reinforced.
12 April 2022 in IEEE Transactions on Industrial Electronics
High voltage direct current (HVdc) detection is essential to ensure the suitability and operation of electrical systems, as well as personal safety. Today there are commercial sensing devices equipped with a safety system that emits audible warnings, but they do not indicate voltage and polarity levels. Likewise, although the scientific literature describes various solutions with satisfactory results, very few of these achievements are found in real-world applications. The purpose of this article is to present a technological alternative based on the study and development of a simple and portable electronic device to enable the detection and quantification of high voltage and polarity in HVdc systems. The principle is based on the detection of corona current by means of an aluminum tip held at a distance of about 5 mm from the energized surface through a radial contact rod. The detected electrical current signal is collected and processed through an electronic system. The performance was analyzed by means of corona discharge models and high voltage experimental tests in real-world conditions. The results demonstrated the satisfactory response of the proposed approach in the detection, quantification, and identification of polarity in a ±600 kV HVdc transmission system, with an error varying from 1.79% to 2.72% compared to theoretical values, as well as its ability to withstand the influence of temperature variations between 18 °C to 29 °C, relative humidity between 56% and 78%, and an atmospheric pressure kept constant at 101.6 kPa. The proposed approach contributes to HVdc monitoring and inspection activities, helping to ensure their operation and suitability.
The evaluation of the response of sensors fixed to the print bed in the fused filament fabrication (FFF) process has been the subject of recent studies due to the increasing use of the FFF process. Many of these studies focus on topics related to monitoring the FFF process through the signals collected by sensors. Recently, some works employing piezoelectric diaphragm and electret microphones can be found in the monitoring of the FFF process, but the influence of the transducer response due to the variation of temperature has not been addressed. Thus, this work presents a study of the response of a low-cost electret microphone attached to the print bed under different temperature values. A 3D printer with polylactic acid (PLA) filament was used in the tests, which consisted of applying the pencil lead break method (PLB on the heated print bed at temperature values ranging from 25 °C to 65 °C. The acoustic waves generated by the tests were captured by the electret microphone attached near the breakage point, and the signals were sampled using an oscilloscope at a frequency of 2 MHz. The signals were processed in the time and frequency domains, followed by comparative analyses between the signals obtained for different temperature values. The results showed that it was not possible to determine a single temperature value at which the response of the electret microphone starts to undergo significant changes, but rather there is inconsistent change in the transducer’s response across all frequency bands, indicating that the influence of temperature takes place in a complex way as frequency varies. This complexity is further evidenced by the non-linear behavior of RMSD values for the evaluated temperatures. Thus, the results can be helpful to those who use this type of transducer attached to the printing bed for monitoring purposes.
This work presents the study of a reproducible acoustic emission method based on the launching of a metallic sphere and low-cost piezoelectric diaphragm. For this purpose, tests were first conducted on a carbon fiber-reinforced polymer structure, and then on an aluminum structure for comparative analysis. The pencil-lead break (PLB) tests were also conducted for comparisons with the proposed method. Different launching heights and elastic deformations of the structures were investigated. The results show higher repeatability for the sphere impact method, as the PLB is more affected by human inaccuracy, and it was also effective in damage detection.
This work presents the study of a reproducible acoustic emission method based on the launching of a metallic sphere and low-cost piezoelectric diaphragm. For this purpose, tests were first conducted on a carbon fiber-reinforced polymer structure, and then on an aluminum structure for comparative analysis. The Pencil Lead Break (PLB) tests were also conducted for comparisons with the proposed method. Different launching heights and elastic deformations of the structures were investigated. The results show higher repeatability for the sphere impact method, as the PLB is more affected by human inaccuracy, and it was also effective in damage detection.