Revati Shriram

Ms. Revati Shriram


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010
Verified
Conference Paper
Closed access
RSRevati Shriram
Revati Shriram
AWAsmita Wakankar
Asmita Wakankar
NDNivedita Daimiwal
Nivedita Daimiwal
DRDipali Ramdasi
Dipali Ramdasi
Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. This paper describes the method developed by the authors to measure systolic blood pressure from pulse transit time (PTT) Pulse transit time is the time taken for the arterial pulse pressure wave to travel from the aortic valve to a peripheral site. It is usually measured from the R wave on the electrocardiogram to a photoplethysmography signal. PTT is inversely proportional to blood pressure. This method does not require an air cuff and only a minimal inconvenience of attaching electrodes and LED/photo detector sensors on a subject. Twenty three healthy subjects (age 18-60 yrs) were studied. Blood pressure measurement is carried out using pulse transit time and is compared with sphygmomanometry, the reference standard and the oscillometric based automatic BP measuring machine. The results show that the standard deviation of their differences was around 3 mmHg. The developed pulse transit time based method can be used as a noninvasive and cuffless alternative to the conventional occluding-cuff approaches for long-term and continuous monitoring of blood pressure.

1 April 2014
Verified
Conference Paper
Closed access
NDNivedita Daimiwal
Nivedita Daimiwal
MSM. Sundhararajan
M. Sundhararajan
RSRevati Shriram
Revati Shriram
Measurement of blood volumetric changes in human body by photoplethysmographic sensors is used in present study. Objective is to measured different parameters that are heart rate, respiratory rate, BP. PPG signal is acquired by PPG sensor, microcontroller and RS 232. The acquired PPG signal is displayed in MATLAB. Frequency domain analysis of PPG signal shows a two peaks first at around 0.25 to 0.35 Hz and second at around 1 to 1.5 Hz. FFT at 1Hz relates to 60 BPM and FFT at 0.25 Hz relates to 15 respiratory cycles per minute. For BP Measurement, the pulse height of PPG is proportional to the difference between the systolic and the diastolic pressure in the arteries. The standard blood pressure monitoring instrument is used to calculate correlation coefficient. The arterial blood pressure is calculated based on these coefficients. PPG signal is used to detect blood pressure pulsations in a finger and achieved an accuracy of (0.8 ± 7) mmHg and (0.9 ± 6) mmHg for systolic and diastolic pressure, respectively. The developed PPG based method can be used as a noninvasive alternative to the conventional occluding-cuff approaches for long-term and continuous monitoring of blood pressure, heart rate and respiratory rate.

1 April 2014
Verified
Conference Paper
Closed access
SUSukhada A. Unde
Sukhada A. Unde
RSRevati Shriram
Revati Shriram
Coherence analysis can be detect for coordination of EEG rhythms between brain areas. It could not reflect the dynamic properties changing with time. Coherence analysis is a method developed on base of classic coherence analysis and signal's joint time-frequency representations in recent years. It was used to extract transient characteristics of interactions among brain areas. It describes the temporal, spatial and frequency relationships of brain activities. This paper discuss the frequency-varying coherence of EEG (Electroencephalogram) to study the coordination mechanism of brain. The power spectral density is the frequency-varying method to study the coordination mechanism of brain areas. The Welch method and the periodogram method are the two methods to study the power spectral density. The results showed that appropriate methods were effective tools for EEG to study the coordination between brain areas.

1 September 2016
Verified
Conference Paper
Closed access
SDSamruddhi Deshpande
Samruddhi Deshpande
RSRevati Shriram
Revati Shriram
This paper presents camera based system which will help blind person for reading text patterns printed on hand held objects. This is the framework to assist visually impaired persons to read text patterns and convert it into the audio output. To obtain the object from the background and extract the text pattern from that object, the system first proposes the method that will capture the image from the camera and object region is detected. The text which are maximally stable are detected using Maximally Stable External Regions (MSER) feature. A novel algorithm is evaluated on variety of scenes. The detected text is compared with the template and converted into the speech output. The text patterns are localized and binarized using Optical Character Recognition (OCR). The recognized text is converted to an audio output. The speech output is given to the blind user. Experimental results shows the analysis of MSER and OCR for different text patterns. MSER shows that it is robust algorithm for the text detection. Therefore, this paper deals with analysis of detection and recognition of different text patterns on different objects.

1 April 2014
Verified
Conference Paper
Closed access
NDNivedita Daimiwal
Nivedita Daimiwal
MSM. Sundhararajan
M. Sundhararajan
RSRevati Shriram
Revati Shriram
Detection of blood volume change in the skin by using Photoplethysmogram (PPG) sensor is based on the principle that hemoglobin in the blood absorbs infrared light than the other tissue. Favorable optical window is around 990 nm range. The reflectance type photoplethysmographic sensor is designed using two different detectors. Objective is to compare the response of PPG sensor by using Light Dependent resistors (LDR) and OPT101 as a detector. Signal is recorded by placing the sensor on a finger tip for wavelength ranging from visible to near IR (400 to 1000 nm) range. It is observed that the PPG signal captured using LDR is around 660 nm wavelength but for the OPT101 response is 500 nm to 1000 nm. That is OPT 101 can be used to capture PPG in visible and infrared region. Brain mapping using optical sensor OPT101 is preferable for the measurement of blood volume and blood flow. For source of 660 nm, LDR or OPT 101 can be used to detect the peripheral pulse. LDR is not suitable for the measurement in infrared range.

1 April 2014
Verified
Conference Paper
Closed access
SSSupriya Shete
Supriya Shete
RSRevati Shriram
Revati Shriram
The effective classification of EEG used for brain computer interface and can be used for silent communication or for recognizing different mental tasks. The electroencephogram (EEG) contains information about brain hence the sub-band decomposition of EEG is used for analyzing many brain diseases. The sub-band decomposition means to extract various brain waves with different frequency bands such as alpha, beta, delta, theta and gamma from EEG signal to get more information from it. The work was carried out to extract various brain waves using discrete wavelet transform. The EEG signal is decompose into five sub-bands alpha, beta, gamma, theta, delta using daubechies and symlet wavelet. Based on application, these decomposed brain waves can be given to any network as input for further analysis. The decomposed signal was further reconstructed to obtain the original signal. Original signal was compared with the reconstructed signal and mean square error (MSE) was calculated. The work carried out shows that the MSE for symlet wavelet is less as compared to that of the daubechies wavelet. Symlet wavelet is the best suited wavelet for sub-band decomposition.