Anton Bereš

Dr. Anton Bereš


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
TTTomáš Toporcer
Tomáš Toporcer
ŠLŠtefan Lukačin
Štefan Lukačin
AKAndrea Kraus
Andrea Kraus
MHMarián Homola
Marián Homola
ABAnton Bereš
Anton Bereš
AKAdrián Kolesár
Adrián Kolesár
Background: Aortic valve replacement (AVR) is the definitive therapy for patients with severe aortic valve stenosis (AoS). The aim of this work is to compare the effect of a mechanical prosthesis (MP) and a bioprosthesis (BP) on the survival of patients aged 50–65 years after AVR. Methods: The retrospective analysis included 276 patients aged 50 to 65 years who had undergone isolated AVR for AoS; 161 patients were implanted with an MP and 115 with a BP. Patient survival, adjusted for age, gender and risk parameters affecting survival, was assessed. A subgroup analysis was performed on the 208 patients with a modern valve (prosthesis models that are no longer used in clinical practice were removed from the sample). Results: After adjusting for risk factors for overall survival as well as for age and sex, the implantation of an MP did not have a significant effect on overall survival in comparison to a BP, at a median follow-up of 10.3 years (p = 0.477). The size of the MP had no significant effect on overall survival either (HR: 1.29; 95%CI: 0.16–10.21; p = 0.812). However, the indexed effective orifice area of the BP had a positive effect on overall survival (HR: 0.09; 95%CI: 0.01–0.78; p = 0.029). Conclusions: The estimated survival of patients aged between 50 and 65 years after implantation of a BP with a sufficiently large indexed effective orifice area may exceed that of patients with an MP.

TTTomáš Toporcer
Tomáš Toporcer
MHMarián Homola
Marián Homola
ABAnton Bereš
Anton Bereš
MTMichal Trebišovský
Michal Trebišovský
TLTomáš Lopuchovský
Tomáš Lopuchovský
AKAdrián Kolesár
Adrián Kolesár
Background: In recent decades, aortic valve surgery has transitioned from conventional median sternotomy (MS) to minimally invasive techniques, including partial upper mini-sternotomy (PUMS) and right anterolateral mini-thoracotomy (RAMT). This study retrospectively compares the outcomes of aortic valve replacement (AVR) using PUMS during the learning phase with those of standard MS. Methods: A retrospective analysis was conducted on patients (n = 211) who underwent AVR for aortic stenosis. They were divided into MS (n = 119) and PUMS (n = 92) groups. Various preoperative, surgical and postoperative parameters, including survival, were examined. Results: Preoperatively, the main difference was age, with PUMS patients being older (67.5 ± 7 vs. 66.5 ± 9.6; p = 0.010). PUMS patients also had longer cardiopulmonary bypass (CPB) and cross-clamping times (99 ± 25 vs. 80 ± 16 min; p < 0.002; 79 ± 18 vs. 65 ± 13 min; p < 0.024). There were no significant differences in body mass index, prosthesis size, indexed effective orifice area, hospitalisation duration or any other monitored parameter. Echocardiographic follow-up found no differences in prosthetic pressure gradients, flow velocity or paravalvular leak between the PUMS and MS groups. Survival rates were similar over 1000 days. Conclusions: The data suggest that PUMS offers comparable surgical outcomes to MS for AVR with additional cosmetic benefits, undeterred by a learning curve.

Verified
Journal Article
Open access
PDF file
TTTomáš Toporcer
Tomáš Toporcer
MHMarián Homola
Marián Homola
ABAnton Bereš
Anton Bereš
MTMichal Trebišovský
Michal Trebišovský
TLTomáš Lopuchovský
Tomáš Lopuchovský
AKAdrián Kolesár
Adrián Kolesár
Background: Aorto–atrial fistula is a rare pathological communication associated with diagnostic difficulties, progressive hemodynamic consequences, and potential infective complications. Methods and Results: We present a 53-year-old woman with a long-standing congenital non-coronary sinus of Valsalva–to–right atrial fistula that had been followed for nine years under the working diagnosis of a Gerbode defect. The communication was first detected at the age of 44 years during pregnancy and was managed conservatively while the patient remained largely asymptomatic. At the age of 53 years, recurrent exertional dyspnea prompted definitive reassessment. Right heart catheterization demonstrated a hemodynamically significant left-to-right shunt at the right atrial level, with a pulmonary-to-systemic blood flow (Qp/Qs) ratio of 2.1. Intraoperatively, the communication was shown to originate immediately above the non-coronary cusp and drain into the right atrium, establishing the diagnosis of a congenital aorto–right atrial fistula. A granulomatous, windsock-like endocardial lesion was identified at its right atrial opening, and Staphylococcus capitis was isolated from surgically obtained tissue. Histopathology showed nonspecific regressive changes without specific features of active infective endocarditis. The fistula was closed with an autologous pericardial patch, and intravenous flucloxacillin was administered because of probable localized infective involvement. Conclusions: This case illustrates the diagnostic difficulty of distinguishing an aorto–atrial fistula from a Gerbode defect and supports careful multimodality evaluation of the anatomical origin and flow characteristics of intracardiac shunts. Persistent high-velocity flow may contribute to endocardial injury and create a substrate for subsequent bacterial colonization, although causality cannot be established from a single case. Isolation of a low-virulence skin commensal from pathological cardiac tissue should be interpreted in the complete clinical, operative, microbiological, and histopathological context rather than automatically classified as contamination.

4 October 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TTTomáš Toporcer
Tomáš Toporcer
LVLukáš Vajda
Lukáš Vajda
ABAnton Bereš
Anton Bereš
JBJaroslav Benedík
Jaroslav Benedík
MHMarián Homola
Marián Homola
AKAdrián Kolesár
Adrián Kolesár
Background/Objectives: Limited availability of pulmonary homografts may restrict right ventricular outflow tract reconstruction after the Ross procedure. This technical note describes the geometric construction of a valved conduit composed of autologous pericardial cusps and a tubularized bovine pericardial patch. Methods: Autologous pericardium (approximately 10 × 8 cm) is treated with 0.9% glutaraldehyde for 10 min, and three size-4 cusps with triangular ears are fashioned using a Fehling template. A bovine pericardial patch (14 × 9 cm) is marked with the cusp attachment baseline, the commissural fixation line, and asymmetric tubularization lines. The cusp implantation field is divided into three equal segments, and each cusp is sutured to the mesothelial surface of the patch with a continuous suture, followed by commissural fixation. The patch is then tubularized, and valve competence is assessed by saline testing. Results: The conduit was constructed in approximately 60 min, in parallel with the main operation, and implanted in four patients undergoing a modified Ross procedure in 2025. Echocardiography on the first postoperative day showed no more than trace pulmonary regurgitation and no conduit obstruction. No conduit-related complications occurred; only early postoperative follow-up is available. Conclusions: The technique allows construction of a valved conduit from autologous and bovine pericardium using widely available materials. Currently, it demonstrates technical feasibility only; hemodynamic performance, safety, and durability remain to be established in larger studies with standardized follow-up.

Verified
Journal Article
Open access
PDF file
PJPeter Na Jakub
Peter Na Jakub
TTTomáš Toporcer
Tomáš Toporcer
MMMatúš Marcin
Matúš Marcin
MTMichal Trebišovský
Michal Trebišovský
ABAnton Bereš
Anton Bereš
AKAdrián Kolesár
Adrián Kolesár
The aim of this study was to retrospectively compare modified Del Nido and blood-based St. Thomas cardioplegia in adult patients undergoing isolated aortic valve replacement (AVR). This retrospective study included adult patients undergoing isolated AVR because of aortic valve stenosis between 2024 and 2025. Patients were stratified into blood-based St. Thomas and modified Del Nido groups. The main modification of the Del Nido solution was the adjustment of the crystalloid-to-blood ratio to 1:4. Preoperative and perioperative variables, as well as postoperative biomarkers, including high-sensitivity troponin I, creatine kinase (CK), CK-MB, and lactate, were analyzed. A total of 93 patients were included in the study (blood-based St. Thomas: n = 22; modified Del Nido: n = 71). No significant differences were observed in cardiopulmonary bypass time [98 min (IQR 84–110) vs. 90 min (IQR 74–110); p = 0.184] or aortic cross-clamp time [75 min (IQR 67–86) vs. 73 min (IQR 62–87); p = 0.345]. High-sensitivity troponin I levels at 24 h were numerically, but not statistically significantly, lower in the blood-based St. Thomas group [1961 ng/L (IQR 1367–4423) vs. 2819 ng/L (IQR 1698–5054); p = 0.240]. CK levels at 6 h were comparable between the groups [8.4 μkat/L (IQR 6.5–10.1) vs. 8.5 μkat/L (IQR 6.0–12.7); p = 0.632], as were CK-MB and lactate levels at all evaluated time points. In exploratory multivariable analyses adjusted for age, sex, preoperative LVEF, cardiopulmonary bypass time, and aortic cross-clamp time, cardioplegia type was not independently associated with postoperative biomarker levels. The less frequent dosing and membrane-stabilizing properties of modified Del Nido cardioplegia did not translate into statistically significant clinical or biochemical advantages in the setting of relatively short, isolated AVR procedures.