SEUNGGI KIM

Mr. SEUNGGI KIM

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SJSung-Yoon Jung
Sung-Yoon Jung
SKSEUNGGI KIM
SEUNGGI KIM
JKJoo-Hyung Kim
Joo-Hyung Kim
SPSe hoon Park
Se hoon Park
Commercial multi-degrees-of-freedom (multi-DOF) myoelectric hand prostheses can perform various hand gestures and grip motions using multiple DOFs. However, as most upper limb amputees have less than two electromyogram (EMG) signals generated at the amputation site, it is difficult to control various hand gestures and grip motions using multi-DOF myoelectric hand prostheses. This paper proposes a multifunctional myoelectric hand prosthesis system that uses only two EMG sensors while improving the convenience of upper limb amputees in everyday life. The proposed system comprises a six-DOF myoelectric hand prosthesis and an easy and effective control algorithm that enables upper limb amputees to perform various hand gestures and grip motions. More specifically, the hand prosthesis has a multi-DOF five-finger mechanism and a small controller that can be mounted inside the hand, allowing it to perform various hand gestures and grip motions. The control algorithm facilitates four grip motions and four gesture motions using the adduction and abduction positions of the thumb, the flexion and extension state of the thumb, and three EMG signals (co-contraction, flexion, and extension) generated using the two EMG sensors. Experimental results indicate that the proposed system is a versatile, flexible, and effective hand prosthesis system for upper limb amputees.

6 August 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSEUNGGI KIM
SEUNGGI KIM
JPJin-Kook Park
Jin-Kook Park
BHBum-Ki Hong
Bum-Ki Hong
NPNa-Yoen Park
Na-Yoen Park
CKChil-Yong Kwon
Chil-Yong Kwon
SESu-Hong Eom
Su-Hong Eom
Microprocessor-controlled knee prostheses (MPKs) face limited accessibility in resource-constrained environments due to high implementation costs and excessive power consumption associated with complex actuators. This study examines the technical feasibility of a low-cost electronically controlled pneumatic knee (ECPK) that combines structural mechanics with minimal electronic control. A functional decoupling strategy was implemented: stance-phase stability is provided by passive kinematic locking of a four-bar linkage over the near-extended stance range, while a lightweight feedforward controller driven by a single joint-axis Hall sensor segments the gait cycle continuously, updates its speed estimate once per step, and adjusts the valve only for swing-phase damping. From the stance duration of the preceding steps, this controller presets the pneumatic valve orifice to compensate for mechanical response delays, so that link rotation speed is regulated semi-actively without powered actuation. System integration and control viability were evaluated in a single-case feasibility study (N = 1), in which the ECPK was compared within subject with a commercial mechanical prosthesis after a 4-week adaptation period. Despite a 400 g distal mass penalty, the semi-active control algorithm was associated with a smaller increase in step-length asymmetry at the highest speed tested. Furthermore, net oxygen cost was lower with the ECPK during high-speed walking. Because the conditions were compared at unmatched self-selected speeds and the ECPK condition reached a respiratory exchange ratio (RER) of 1.13, this observation is hypothesis-generating. Coupling passive four-bar stance stability with minimal electronic swing regulation is therefore a viable engineering basis for accessible prostheses, and the present study establishes its technical feasibility rather than its clinical effectiveness.

1 May 2025 in Journal of Institute of Control, Robotics and Systems
Verified
Journal Article
Closed access
SKSEUNGGI KIM
SEUNGGI KIM
JPJin-Kook Park
Jin-Kook Park
HSHyun-Jun Shin
Hyun-Jun Shin
SESu-Hong Eom
Su-Hong Eom
KKKyoung-Ho Kim
Kyoung-Ho Kim
SPSe hoon Park
Se hoon Park
This study introduces an electronically controlled pneumatic knee (ECPK) prosthesis designed to enhance gait adaptability and stability in transfemoral amputees. While pneumatic prostheses are lightweight and cost-efficient, they often lack responsiveness and stability. Therefore, a 4-bar linkage mechanism with a pneumatic cylinder is implemented, along with a motor-driven control algorithm using a unipolar Hall sensor to adjust damping based on real-time gait phase detection. A dedicated PC application is also developed to monitor gait parameters and configure control settings. Gait experiments with a transfemoral amputee demonstrate that an ECPK prothesis improves step length symmetry, dynamic stability, and responsiveness over fixed-nozzle and conventional pneumatic prostheses. These findings suggest that the ECPK prosthesis effectively bridges the gap between simple mechanical design and adaptive performance, providing a practical and scalable solution for improving prosthetic gait support.