ISABEL FERNANDEZ LIZARANZU

ISABEL FERNANDEZ LIZARANZU

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2023 in Contemporary Clinical Trials
Verified
Journal Article
Open access
MPMichael Pavlides
Michael Pavlides
FMFerenc E. Mózes
Ferenc E. Mózes
SASalma Akhtar
Salma Akhtar
KWKristy Wonders
Kristy Wonders
JCJeremy Cobbold
Jeremy Cobbold
SHStephen Harrison
Stephen Harrison
Non-alcoholic fatty liver disease (NAFLD) is the liver manifestation of the metabolic syndrome with global prevalence reaching epidemic levels. Despite the high disease burden in the population only a small proportion of those with NAFLD will develop progressive liver disease, for which there is currently no approved pharmacotherapy. Identifying those who are at risk of progressive NAFLD currently requires a liver biopsy which is problematic. Firstly, liver biopsy is invasive and therefore not appropriate for use in a condition like NAFLD that affects a large proportion of the population. Secondly, biopsy is limited by sampling and observer dependent variability which can lead to misclassification of disease severity. Non-invasive biomarkers are therefore needed to replace liver biopsy in the assessment of NAFLD. Our study addresses this unmet need. The LITMUS Imaging Study is a prospectively recruited multi-centre cohort study evaluating magnetic resonance imaging and elastography, and ultrasound elastography against liver histology as the reference standard. Imaging biomarkers and biopsy are acquired within a 100-day window. The study employs standardised processes for imaging data collection and analysis as well as a real time central monitoring and quality control process for all the data submitted for analysis. It is anticipated that the high-quality data generated from this study will underpin changes in clinical practice for the benefit of people with NAFLD. Study Registration: clinicaltrials.gov: NCT05479721.

23 October 2024 in Heritage
Verified
Journal Article
Open access
PDF file
GVGiovanna Vasco
Giovanna Vasco
HAHélène Aureli
Hélène Aureli
ILISABEL FERNANDEZ LIZARANZU
ISABEL FERNANDEZ LIZARANZU
JMJavier Moreno-Soto
Javier Moreno-Soto
AKAnabelle Kriznar
Anabelle Kriznar
MRMiguel Angel Respaldiza
Miguel Angel Respaldiza
In the last decade, the hyperspectral imaging (HSI) method allowed performing non-invasive analysis in the field of cultural heritage. However, a considerable limitation was given by redundant and time-consuming features, with the necessary application of statistical algorithms and image-processing tools to extract relevant information. In this study, the Centro Nacional de Aceleradores (CNA) and the Group of Interdisciplinary Physics (GFI) of the School of Engineering (ETSI) of the University of Seville tested the application of three different hyperspectral cameras in the visible and near-infrared (VNIR) and short-wave infrared (SWIR) range for the investigation of an ancient painting. A reference-based procedure was realised to build a starting personal library and to evaluate the best working conditions for non-invasive and non-destructive characterisation with data treatment using the commercially available software Evince® and Specim IQ® to apply, respectively, the Principal Component Analysis (PCA) model functions and the classification method. The evaluation of the protocol was tested by acquiring complementary information by X-ray fluorescence (XRF), Ultraviolet Luminescence (UVL) imaging, and Infrared Reflectography (IRR). This exploration established a simplified protocol to analyse the large collection of paintings of the Archbishop’s Palace and the Cathedral of Seville.

1 November 1995 in Journal of Parenteral and Enteral Nutrition
Verified
Journal Article
Closed access
EMEliane Moreira
Eliane Moreira
Luis FontanaLuis Fontana
Luis Fontana
MLM Isabel Torres López
M Isabel Torres López
ILISABEL FERNANDEZ LIZARANZU
ISABEL FERNANDEZ LIZARANZU
ARAntonio Ríos
Antonio Ríos
AGAngel Gil
Angel Gil

19 September 2022 in Operative Neurosurgery
Verified
Journal Article
Open access
EGEmilio Gomez-Gonzalez
Emilio Gomez-Gonzalez
FMFrancisco Javier Munoz-Gonzalez
Francisco Javier Munoz-Gonzalez
ABAlejandro Barriga-Rivera
Alejandro Barriga-Rivera
MPManuel Perales
Manuel Perales
MGManuel Guerrero-Claro
Manuel Guerrero-Claro
JMJavier Márquez-Rivas
Javier Márquez-Rivas
BACKGROUND: Obstructive failure of implanted shunts is the most common complication in the treatment of hydrocephalus. Biological material and debris accumulate in the inner walls of the valve and catheters block the normal flow of the drained cerebrospinal fluid causing severe symptoms with high morbidity and mortality. Unfortunately, at present, there is no effective preventive protocol or cleaning procedure available. OBJECTIVE: To assess whether externally applied, focused ultrasound beams can be used to resuspend deposits accumulated in brain shunts safely. METHODS: A computational model of an implanted brain shunt was implemented to test the initial design parameters of a system comprising several ultrasound transducers. Under laboratory conditions, configurations with 3 and 4 transducers were arranged in a triangle and square pattern with their radiation axis directed towards a target model of the device, 2 catheters and a brain shunt filled with water and deposited graphite powder. The ultrasound beams were then concentrated on the device across a head model. RESULTS: The computational model revealed that by using only 3 transducers, the acoustic field intensity on the valve was approximately twice that on the brain surface suggesting that acoustic cavitation could be selectively achieved. Resuspension of graphite deposits inside the catheters and the valve were then physically demonstrated and video-recorded with no temperature increase. CONCLUSION: The technology presented here has the potential to be used routinely as a noninvasive, preventive cleaning procedure to reduce the likelihood of obstruction-related events in patients with hydrocephalus treated with an implanted shunt.

28 April 2022 in arXiv
Verified
Preprint
Open access
PDF file
EGEmilio Gomez-Gonzalez
Emilio Gomez-Gonzalez
OMOlga Muñoz
Olga Muñoz
JGJuan Carlos Gomez-Martin
Juan Carlos Gomez-Martin
JAJesus Aceituno-Castro
Jesus Aceituno-Castro
BFBeatriz Fernández-Muñoz
Beatriz Fernández-Muñoz
JMJavier Márquez-Rivas
Javier Márquez-Rivas
Objective: To conduct a proof-of-concept study of the detection of two synthetic models of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using polarimetric imaging. Methods: Two SARS-CoV-2 models were prepared as engineered lentiviruses pseudotyped with the G protein of the vesicular stomatitis virus, and with the characteristic Spike protein of SARS-CoV-2. Samples were preparations in two biofluids (saline solution and artificial saliva), in four concentrations, and deposited as 5-{\mu}L droplets on a supporting plate. The angles of maximal degree of linear polarization (DLP) of light diffusely scattered from dry residues were determined using Mueller polarimetry of 87 samples at 405 nm and 514 nm. A polarimetric camera was used for simultaneous imaging of several samples under 380-420 nm illumination at angles similar to those of maximal DLP. A per-pixel image analysis included quantification and combination of polarization feature descriptors in other 475 samples. Results: The angles (from sample surface) of maximal DLP were 3 degrees for 405 nm and 6 degrees for 514 nm. Similar viral particles that differ only in the characteristic spike protein of the SARS-CoV-2, their corresponding negative controls, fluids, and the sample holder were discerned from polarimetric image analysis at 10-degree and 15-degree configurations. Conclusion: Polarimetric imaging in the visible spectrum has the potential for non-contact, reagent-free detection of viruses in multiple dry fluid residues simultaneously. Further analysis including real SARS-CoV-2 in human samples -- particularly, fresh saliva -- are required. Significance: Polarimetric imaging under visible light could contribute to fast, cost-effective screening of SARS-CoV-2 and other pathogens.