Stefan Borov

Mr. Stefan Borov

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
SBStefan Borov
Stefan Borov
BBBenito Baldauf
Benito Baldauf
JHJana Henke
Jana Henke
HPHerribert Pavaci
Herribert Pavaci
APArben Perani
Arben Perani
HBHendrik Bonnemeier
Hendrik Bonnemeier
TauroPace (Tauropharm, Bavaria Germany), a taurolidine solution for combating cardiac implantable electronic device (CIED) infection, was compared with a historical control of 3% hydrogen peroxide (H2O2) in a prospective observational study. The device pocket was irrigated, and all hardware accessible within (leads, suture sleeves, pulse generator) was wiped with H2O2, TauroPace, or taurolidine in a galenic formulation during any invasive CIED procedure at the study centre. Only CIED procedures covered by TauroPace or H2O2 from 1 January 2017 to 28 February 2022 were included for analysis. Patients who underwent >1 procedure were censored for the last treatment group and reassigned at the next procedure. The primary endpoint was major CIED infection within 3 months. The secondary endpoints were CIED infection beyond 3 months, adverse events potentially related to the antimicrobial solutions, CIED system, procedure, and death, till the end of follow-up. TauroPace covered 654 procedures on 631 patients, and H2O2 covered 551 procedures on 532 patients. The TauroPace group had more patient risk factors for infection than the H2O2 group (P = 0.0058) but similar device and procedure-specific risk factors (P = 0.17). Cardiac implantable electronic device infection occurred in 0/654 (0%) of the TauroPace group and 6/551 (1.1%) of the H2O2 group (P = 0.0075). Death occurred in 23/654 (3.5%) of the TauroPace group and 14/551 (2.5%) of the H2O2 group (P = 0.33). Non-infection related adverse events were rarer in the TauroPace (3.8%) than the H2O2 (6.0%) group (P = 0.0802). TauroPace is safe but more effective than H2O2 in reducing CIED infection. ClinicalTrials.gov Identifier: NCT05576194

Verified
Journal Article
Open access
PDF file
MGMarzia Giaccardi
Marzia Giaccardi
BBBenito Baldauf
Benito Baldauf
ELErnest W. Lau
Ernest W. Lau
SBStefan Borov
Stefan Borov
HBHendrik Bonnemeier
Hendrik Bonnemeier
We reported the novel use of a taurolidine-containing antimicrobial solution in the successful salvage of a partially exposed and polymicrobially infected cardiac implantable electronic device pulse generator in a frail patient unfit for lead extraction. The old, salvaged device was entirely internalized, and there were no signs of recurrent infection at 9 months follow-up.

15 September 2023 in Methods and Protocols
Verified
Journal Article
Open access
PDF file
RVReinhard Vonthein
Reinhard Vonthein
BBBenito Baldauf
Benito Baldauf
SBStefan Borov
Stefan Borov
ELErnest W. Lau
Ernest W. Lau
MGMarzia Giaccardi
Marzia Giaccardi
HBHendrik Bonnemeier
Hendrik Bonnemeier
Background: Cardiac implantable electronic device (CIED) placement comes with certain complications. CIED infection is a severe adverse event related to CIED placement. In randomised controlled trials, the preoperative intravenous administration of antibiotics and the adjunctive use of an antibiotic mesh envelope resulted in significant reduction in infections related to cardiac implantable electronic devices. The adjunctive use of taurolidine for this purpose is relatively novel and not considered in the guidelines. The required evidence may consist of a set of clinical studies. Methods: The European TauroPaceTM registry (ETPR) prospectively evaluates every consecutive invasive procedure involving any CIED with adjunct TauroPace™ use in the contributing centres. As the estimation of the infection rate needs to be defensible, only interventions registered prior to the procedure will be followed-up. The endpoint is a major cardiac implantable electronic device infection according to the novel CIED infection criteria (1). Secondary endpoints comprise all-cause mortality, complications, adverse events of all grades, and major CIED infections during all follow-up examinations. The follow-up times are three months, twelve months, and eventually 36 months, as acute, subacute, and long-term CIED infections are of interest. Results: As the rate of CIED infections is expected to be very low, this registry is a multicentre, international project that will run for several years. Several reports are planned. The analyses will be included in the case number calculations for future randomised controlled trials. Conclusions: The ETPR will accumulate large case numbers to estimate small event rates more precisely; we intend to follow up on participants for years to reveal possible late effects.