The aim of this study was to quantitatively analyze quite standing postural stability of adolescent idiopathic scoliosis (AIS) patients in respect to three sensory systems (visual, vestibular, and somatosensory). In this study, we analyzed the anterior-posterior center of pressure (CoP) signal using discrete wavelet transform (DWT) between AIS patients (n = 32) and normal controls (n = 25) during quiet standing. The energy rate (∆EEYE%) of the CoP signal was significantly higher in the AIS group than that in the control group at levels corresponding to vestibular and somatosensory systems (p < 0.01). This implies that AIS patients use strategies to compensate for possible head position changes and spinal asymmetry caused by morphological deformations of the spine through vestibular and somatosensory systems. This could be interpreted that such compensation could help them maintain postural stability during quiet standing. The interpretation of CoP signal during quiet standing in AIS patients will improve our understanding of changes in physical exercise ability due to morphological deformity of the spine. This result is useful for evaluating postural stability before and after treatments (spinal fusion, bracing, rehabilitation, and so on).
Whole-body center of gravity (CG) movements in relation to the center of pressure (COP) offer insights into the balance control strategies of the human body. Existing CG measurement methods using expensive measurement equipment fixed in a laboratory environment are not intended for continuous monitoring. The development of wireless sensing technology makes it possible to expand the measurement in daily life. The insole system is a wearable device that can evaluate human balance ability by measuring pressure distribution on the ground. In this study, a novel protocol (data preparation and model training) for estimating the 3-axis CG trajectory from vertical plantar pressures was proposed and its performance was evaluated. Input and target data were obtained through gait experiments conducted on 15 adult and 15 elderly males using a self-made insole prototype and optical motion capture system. One gait cycle was divided into four semantic phases. Features specified for each phase were extracted and the CG trajectory was predicted using a bi-directional long short-term memory (Bi-LSTM) network. The performance of the proposed CG prediction model was evaluated by a comparative study with four prediction models having no gait phase segmentation. The CG trajectory calculated with the optoelectronic system was used as a golden standard. The relative root mean square error of the proposed model on the 3-axis of anterior/posterior, medial/lateral, and proximal/distal showed the best prediction performance, with 2.12%, 12.97%, and 12.47%. Biomechanical analysis of two healthy male groups was conducted. A statistically significant difference between CG trajectories of the two groups was shown in the proposed model. Large CG sway of the medial/lateral axis trajectory and CG fall of the proximal/distal axis trajectory is shown in the old group. The protocol proposed in this study is a basic step to have gait analysis in daily life. It is expected to be utilized as a key element for clinical applications.
Accurate registration between medical images and patient anatomy is crucial for surgical navigation systems in minimally invasive surgeries. This study introduces a novel deep learning-based refinement step to enhance the accuracy of surface registration without disrupting established workflows. The proposed method integrates a machine learning model between conventional coarse registration and ICP fine registration. A deep-learning model was trained using simulated anatomical landmarks with introduced localization errors. The model architecture features global feature-based learning, an iterative prediction structure, and independent processing of rotational and translational components. Validation with silicon-masked head phantoms and CT imaging compared the proposed method to both conventional registration and a recent deep-learning approach. The results demonstrated significant improvements in target registration error (TRE) across different facial regions and depths. The average TRE for the proposed method (1.58 ± 0.52 mm) was significantly lower than that of the conventional (2.37 ± 1.14 mm) and previous deep-learning (2.29 ± 0.95 mm) approaches (p < 0.01). The method showed a consistent performance across various facial regions and enhanced registration accuracy for deeper areas. This advancement could significantly enhance precision and safety in minimally invasive surgical procedures.