Esophagectomy is the standard treatment for stage I esophageal squamous cell carcinoma (ESCC). We conducted a single-arm prospective study to confirm the efficacy and safety of selective chemoradiotherapy (CRT) based on findings from endoscopic resection (ER). We performed a prospective study of patients with T1b (SM1-2) N0M0 thoracic ESCC from December 2006 through July 2012; 176 patients underwent ER. Based on the findings from ER, patients received the following: no additional treatment for patients with pT1a tumors with a negative resection margin and no lymphovascular invasion (group A); prophylactic CRT with 41.4 Gy delivered to locoregional lymph nodes for patients with pT1b tumors with a negative resection margin or pT1a tumors with lymphovascular invasion (group B); or definitive CRT (50.4 Gy) with a 9-Gy boost to the primary site for patients with a positive vertical resection margin (group C). Chemotherapy comprised 5-fluorouracil and cisplatin. The primary end point was 3-year overall survival in group B, and the key secondary end point was 3-year overall survival for all patients. If lower limits of 90% confidence intervals for the primary and key secondary end points exceeded the 80% threshold, the efficacy of combined ER and selective CRT was confirmed. Based on the results from pathology analysis, 74, 87, and 15 patients were categorized into groups A, B, and C, respectively. The 3-year overall survival rates were 90.7% for group B (90% confidence interval, 84.0%-94.7%) and 92.6% in all patients (90% confidence interval, 88.5%-95.2%). In a prospective study of patients with T1b (SM1-2) N0M0 thoracic ESCC, we confirmed the efficacy of the combination of ER and selective CRT. Efficacy is comparable to that of surgery, and the combination of ER and selective CRT should be considered as a minimally invasive treatment option. UMIN-Clinical Trials Registry no.: UMIN000000553.
Background: This study was conducted to evaluate the real-world safety and efficacy of boron neutron capture therapy (BNCT) with borofalan(10B) in Japanese patients with locally advanced or locally recurrent head and neck cancer (LA/LR-HNC). Methods: This prospective, multicenter observational study was initiated in Japan in May 2020 and enrolled all patients who re-ceived borofalan(10B) as directed by regulatory authorities. Patient enrollment continued until at least 150 patients were enrolled, and adverse events attributable to drugs, treatment devices, and BNCT were evaluated. The patients with LA/LR-HNC were systematically evaluated to determine efficacy. Results: The 162 patients enrolled included 144 patients with squamous cell carcinoma of the head and neck (SCCHN), 17 patients with non-SCCHN (NSCCHN), and 1 patient with glioblastoma. Treatmentrelated adverse events (TRAEs) were hyperamylasemia (84.0%), stomatitis (51.2%), sialoadenitis (50.6%), and alopecia (49.4%) as acute TRAEs and dysphagia (4.5%), thirst (2.6%), and skin disorder (1.9%) as more common late TRAEs. One- and two-year OS rates in patients with recurrent SCCHN were 78.8% and 60.7%, respectively. Conclusions: This post-marketing surveillance confirmed the safety and efficacy of BNCT with borofalan(10B) in patients with LA/LR-HNC in a real-world setting.
The world’s first accelerator based epithermal neutron source for clinical boron neutron capture therapy (BNCT) was designed, developed, and commissioned between 2008 and 2010 by Sumitomo Heavy Industries in collaboration with Kyoto University at the Kyoto University Institute for Integrated Radiation and Nuclear Science. The accelerator system is cyclotron-based and accelerates a proton up to an energy of approximately 30 MeV. The proton strikes a beryllium target, which produces fast neutrons that traverse a beam shaping assembly composed of a combination of lead, iron, aluminum, and calcium fluoride to reduce the neutron energy down to the epithermal range (∼10 keV) suitable for BNCT. The system is designed to produce an epithermal neutron flux of up to 1.4 × 10 9 n · cm − 2 · s − 1 (exiting from the moderator of a 12 cm diameter collimator) with a proton current of 1 mA. In 2017, the same type of accelerator was installed at the Kansai BNCT Medical Center and in March 2020 the system received medical device approval in Japan (Sumitomo Heavy Industries, NeuCure® BNCT system). Soon after, BNCT for unresectable, locally advanced, and recurrent carcinoma of the head and neck region was approved by the Japanese government for reimbursement covered by the national health insurance system.