Research from JAMA Otolaryngology–Head & Neck Surgery — Visual Acuity While Walking and Oscillopsia Severity in Healthy Subjects and Patients With Unilateral and Bilateral Vestibular Function Loss
Objective: To optimize the current diagnostic and treatment procedures for patients with bilateral vestibulopathy (BV), this study aimed to determine the complete spectrum of symptoms associated with BV.Method: A prospective mixed-method study design was used. Qualitative data were collected by performing semi-structured interviews about symptoms, context, and behavior. The interviews were recorded and transcribed until no new information was obtained. Transcriptions were analyzed in consensus by two independent researchers. In comparison to the qualitative results, quantitative data were collected using the Dizziness Handicap Inventory (DHI), Hospital Anxiety and Depression Scale (HADS) and a health-related quality of life questionnaire (EQ-5D-5L).Results: Eighteen interviews were transcribed. Reported symptoms were divided into fourteen physical symptoms, four cognitive symptoms, and six emotions. Symptoms increased in many situations, such as darkness (100%), uneven ground (61%), cycling (94%) or driving a car (56%). These symptoms associated with BV often resulted in behavioral changes: activities were performed more slowly, with greater attention, or were avoided. The DHI showed a mean score of severe handicap (54.67). The HADS questionnaire showed on average normal results (anxiety = 7.67, depression = 6.22). The EQ-5D-5L demonstrated a mean index value of 0.680, which is lower compared to the Dutch age-adjusted reference 0.839 (60–70 years).Conclusion: BV frequently leads to physical, cognitive, and emotional complaints, which often results in a diminished quality of life. Importantly, this wide range of symptoms is currently underrated in literature and should be taken into consideration during the development of candidacy criteria and/or outcome measures for therapeutic interventions such as the vestibular implant.
Vestibular implants are devices designed to rehabilitate patients with a bilateral vestibular loss (BVL). These patients lack a properly functioning vestibulo-ocular reflex (VOR), which impairs gaze stabilization abilities and results in an abnormal loss of visual acuity (VA) in dynamic situations (i.e., severely limiting the patient’s ability to read signs or recognize faces while walking). We previously demonstrated that the VOR can be artificially restored in a group of BVL patients fitted with a prototype vestibular implant. This study was designed to investigate whether these promising results could be translated to a close-to-reality task, significantly improving VA abilities while walking. Six BVL patients previously implanted with a vestibular implant prototype participated in the experiments. VA was determined using Sloan letters displayed on a computer screen, in four conditions: (1) with the patient standing still without moving (static), (2) while the patient was walking on a treadmill at constant speed with the vestibular implant prototype turned off (systemOFF), (3) while the patient was walking on a treadmill at constant speed with the vestibular implant prototype turned on providing coherent motion information (systemONmotion), and (4) a “placebo” condition where the patient was walking on a treadmill at constant speed with the vestibular implant prototype turned on providing reversed motion information (systemONsham). The analysis (one-way repeated measures analysis of variance) revealed a statistically significant effect of the test condition (F(3,12) = 30.5, p<0.001). Significant decreases in VA were observed with the systemOFF condition when compared to the static condition (Tukey post-hoc p<0.001). When the vestibular implant was turned on,delivering pertinent motion information (systemONmotion) the VA improved to close to normal values. The improvement disappeared in the placebo condition (systemONsham) and VA values also dropped significantly in this condition (Tukey post-hoc p<0.001). These results are a significant step forward in the field, demonstrating for the first time in humans that gaze stabilization abilities can be restored with a vestibular implant prototype. The vestibular implant shows considerable promise of being the first-ever effective therapeutic alternative for patients with a BVL in the near future.
The impact of vibrotactile feedback of the gravity vector, provided by a “balance” belt worn around the waist, was evaluated in 39 patients with a severe bilateral vestibular loss, confirmed by extensive laboratory testing and suffering from a low quality of life, mainly due to imbalance. The mobility and balance score (MBS) of all patients prior to the use of the belt was equal or less than 5 out of a scale of 10. Thirty-one out of the 39 patients experienced the effect of the belt on their balance and mobility as positive in a preselection trial of 2 h in the hospital. The 31 positive responders then used the belt for 1 month in daily life. The average MBS increased significantly from 4.2 to 7.9 (paired T test, T = 9.82, p < 0.00001). Twenty-three out of 31 patients reported a benefit ranging from an improvement of 60–200% in their MBS. Eight patients did not experience any benefit. In summary, 23 out of 39 patients with a severe imbalance due to a bilateral vestibular loss experienced a clear benefit of vibrotactile feed = back in daily life. We conclude that vibrotactile feedback via the waist can serve as an effective prothesis for patients with severe bilateral vestibular loss to improve the quality of life.
The purpose of this study was to evaluate whether it is possible to restore the high-frequency angular vestibulo-ocular reflex (aVOR) in patients suffering from a severe bilateral vestibulopathy (BV) and implanted with a vestibular implant prototype. Three patients (S1–3) participated in the study. They received a prototype vestibular implant with one to three electrode branches implanted in the proximity of the ampullary branches of the vestibular nerve. Five electrodes were available for electrical stimulation: one implanted in proximity of the left posterior ampullary nerve in S1, one in the left lateral and another one in the superior ampullary nerves in S2, and one in the right lateral and another one in the superior ampullary nerves in S3. The high-frequency aVOR was assessed using the video head impulse test (EyeSeeCam; EyeSeeTec, Munich, Germany), while motion-modulated electrical stimulation was delivered via one of the implanted vestibular electrodes at a time. aVOR gains were compared to control measurements obtained in the same patients when the device was not activated. In three out of the five tested electrodes the aVOR gain increased monotonically with increased stimulation strength when head impulses were delivered in the plane of the implanted canal. In these cases, gains ranging from 0.4 to values above 1 were measured. A “reversed” aVOR could also be generated when inversed stimulation paradigms were used. In most cases, the gain for excitatory head impulses was superior to that recorded for inhibitory head impulses, consistent with unilateral vestibular stimulation. Improvements of aVOR gain were generally accompanied by a concomitant decrease of corrective saccades, providing additional evidence of an effective aVOR. High inter-electrode and inter-subject variability were observed. These results, together with previous research, demonstrate that it is possible to restore the aVOR in a broad frequency range using motion-modulated electrical stimulation of the vestibular afferents. This provides additional encouraging evidence of the possibility of achieving a useful rehabilitation alternative for patients with BV in the near future.
The primary goal of the vestibular implant is to restore the vestibular function in patients with a disabling bilateral vestibular loss for whom there is currently no available treatment. The prototype developed by our team is a hybrid system consist