Microneedles (MNs) hold significant potential for applications in transdermal drug delivery and biosensing. However, when traditional 3D printing technology is used for their manufacture, a substantial deviation in output size occurs. The effects of various parameters on the morphology of MNs produced through microscale 3D printing remain unclear. This study investigated the relationship between the design and fabrication of acrylic resin MNs and their output forms via a projection microstereolithography (PµSL) technology system. Modifying the shape parameters and array configurations elucidates the causes of size deviation and proposes a control strategy. This is particularly significant for the prototyping and mold manufacturing of MNs in relevant fields. This study indicates that a printing layer thickness of 10 µm optimally balances efficiency and clinical conversion requirements. Additionally, an exposure intensity of 65 mW/cm2 achieves both a high fidelity and an appropriate base size. The printing angle significantly influences the morphology and mechanical properties of MNs. The diameter and aspect ratio of solid MNs correlate with their dimensional stability. Clinically, conical or quadrilateral MNs with defined parameters are recommended. A critical spacing (≥40 µm) and an optimal arrangement of the MN arrays were established. The specific exposure intensity and vertical printing angle of the hollow MNs ensure the precision of the micropore diameter and wall thickness. This approach offers theoretical insights and process parameters essential for high-precision, customizable MN engineering design.
16 September 2024 in Journal of Applied Electrochemistry
Recent studies have identified microneedle (MN) arrays as promising alternatives for transdermal drug delivery. This study investigated the properties of novel staggered MN arrays design featuring two distinct heights of MNs. The staggered MN arrays were precisely fabricated via PμSL light-cured 3D printing technology. The arrays were systematically evaluated for their morphology, fracture force, skin penetration ability, penetration mechanism, and drug delivery capability. The results demonstrated that the staggered MN arrays punctured the skin incrementally, leveraging the benefits of skin deformation during the puncture process. This approach effectively reduced the puncture force needed, achieving a maximum reduction of approximately 80.27% due to variations in the staggered height. Additionally, the staggered design facilitated skin penetration, as confirmed by the results of the rat skin hematoxylin-eosin (H&E) staining experiments. Compared with 3D-printed planar structures and highly uniform MN arrays, the staggered design exhibited enhanced hydrophilicity, as evidenced by a reduction in the contact angle from approximately 93° to 70°. Simulated drug release images of both coated and hollow staggered MNs illustrated the release and delivery capabilities of these structures across various skin layers, and the staggered design expanded the effective area of the MN arrays within the vertical dimension of the skin layers. This study offers both experimental and theoretical foundations for developing MN arrays with three–dimensional structural distributions, thereby facilitating advancements in MN array technology.
31 October 2023 in Journal of Applied Electrochemistry
Co-Cr-Mo alloy as a human body implant material has a long history, because of its excellent corrosion resistance and biocompatibility, and is widely used in human hip joint materials. Co-Cr-Mo alloy in the human body is often in a passivation state; the formation of dense oxide film on the alloy surface prevents further corrosion of the alloy. The main component of the passivation film is the oxide of Cr, so a layer of oxide film formed by Cr on the surface of Co-Cr-Mo alloy is the reason for its good corrosion resistance. In biocompatibility, cytotoxicity is the first choice and necessary option for biological evaluation, and cytotoxicity can quickly detect the effect of materials on cells in a relatively short time. Therefore, this research conducted a comparative evaluation on the corrosion resistance and biocompatibility of forged Co-Cr-Mo alloys produced in domestic and foreign alloys in line with medical standards. Three simulated human body fluids and Princeton electrochemical station were selected for corrosion resistance experiments, and it was found that the corrosion resistance of four alloys in sodium citrate solution inside and outside China would be reduced. All the alloys exhibit secondary passivation behavior in Hanks solution, which improves the corrosion resistance of the alloys. According to the self-corrosion potential Ecorr analysis, the corrosion resistance of domestic B alloy is the best, while that of foreign R31537 alloy is poor. In the biocompatibility experiment, the biocompatibility of Co-Cr-Mo alloy was evaluated through the measurement of contact Angle and cytotoxicity reaction. The experimental results show that Co-Cr-Mo alloy is a hydrophilic material, and the contact Angle of foreign R31537 alloy is smaller, indicating that the surface of R31537 alloy is more suitable for cell adhesion and spreading. According to the qualitative and quantitative analysis of the cytotoxicity experiment, the toxic reaction grade of domestic A, B and R31537 alloy is grade 1, the toxic reaction grade of C alloy is grade 2, and C alloy has a slight toxic reaction.
The service life of graphite anodes—key consumables in the Pr/Nd fluoride molten salt electrolysis process—directly governs production continuity, cost-efficiency, and supply chain stability. This study systematically evaluated five industrial-grade anodes produced from different raw materials and processes. Multimodal characterization—combining macroscopic and microscopic morphology, SEM/EDS, XRD, Raman, and physical property analysis—was employed to correlate initial anode properties with corrosion-induced morphological and mass changes during electrolysis. The results show that the raw material quality and preparation methods synergistically regulate both the crystal structure and microstructure, thereby governing the corrosion behaviour and mass loss. Anodes #2 and #3, which were fabricated from high-quality petroleum coke and subjected to full densification and graphitization, exhibited high graphitization (93.7–94.5%), large crystallites (59.6–64.5 nm), minimal defects (low ID/IG), and suppressed microporosity, leading to the lowest mass loss (10.2 ± 0.8 kg and 10.6 ±0.9 kg). In contrast, anodes #1, #4, and #5, made from recycled graphite without graphitization, contained abundant structural defects and large pores and led to greater morphological changes and quality losses. Moreover, for recycled graphite anodes, the presence of large pores and cracks is one of the important reasons for their failure. This work clarifies the “process–microstructure–mass loss” relationship in graphite anodes for Pr/Nd electrolysis, offering key insights for designing high-performance anodes and advancing sustainable rare earth production.