Abhishek Jain

Dr. Abhishek Jain

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2014 in Nature Biotechnology
Verified
Journal Article
Closed access
PDF file
DLDaniel C Leslie
Daniel C Leslie
AWAnna Wayerhouse
Anna Wayerhouse
JBJulia B Berthet
Julia B Berthet
TVThomas M Valentin
Thomas M Valentin
AWAlexander L Watters
Alexander L Watters
DIDonald E Ingber
Donald E Ingber

24 January 2015 in Annual Review of Pathology: Mechanisms of Disease
Verified
Journal Article
Closed access
KBKambez H. Benam
Kambez H. Benam
SDStephanie Dauth
Stephanie Dauth
BHBryan Hassell
Bryan Hassell
AHAnna Herland
Anna Herland
AJAbhishek Jain
Abhishek Jain
DIDonald E Ingber
Donald E Ingber
The ultimate goal of most biomedical research is to gain greater insight into mechanisms of human disease or to develop new and improved therapies or diagnostics. Although great advances have been made in terms of developing disease models in animals, such as transgenic mice, many of these models fail to faithfully recapitulate the human condition. In addition, it is difficult to identify critical cellular and molecular contributors to disease or to vary them independently in whole-animal models. This challenge has attracted the interest of engineers, who have begun to collaborate with biologists to leverage recent advances in tissue engineering and microfabrication to develop novel in vitro models of disease. As these models are synthetic systems, specific molecular factors and individual cell types, including parenchymal cells, vascular cells, and immune cells, can be varied independently while simultaneously measuring system-level responses in real time. In this article, we provide some examples of these efforts, including engineered models of diseases of the heart, lung, intestine, liver, kidney, cartilage, skin and vascular, endocrine, musculoskeletal, and nervous systems, as well as models of infectious diseases and cancer. We also describe how engineered in vitro models can be combined with human inducible pluripotent stem cells to enable new insights into a broad variety of disease mechanisms, as well as provide a test bed for screening new therapies.

17 May 2017 in Clinical Pharmacology & Therapeutics
Verified
Journal Article
Closed access
PDF file
AJAbhishek Jain
Abhishek Jain
RBR Barrile
R Barrile
AMAndries van der Meer
Andries van der Meer
AMA Mammoto
A Mammoto
TMT Mammoto
T Mammoto
DIDE Ingber
DE Ingber

6 January 2016 in Nature Communications
Verified
Journal Article
Open access
AJAbhishek Jain
Abhishek Jain
AGAmanda Graveline
Amanda Graveline
AWAnna Wayerhouse
Anna Wayerhouse
AVAndyna Vernet
Andyna Vernet
RFRobert Flaumenhaft
Robert Flaumenhaft
DIDonald E Ingber
Donald E Ingber
Accurate assessment of blood haemostasis is essential for the management of patients who use extracorporeal devices, receive anticoagulation therapy or experience coagulopathies. However, current monitoring devices do not measure effects of haemodynamic forces that contribute significantly to platelet function and thrombus formation. Here we describe a microfluidic device that mimics a network of stenosed arteriolar vessels, permitting evaluation of blood clotting within small sample volumes under pathophysiological flow. By applying a clotting time analysis based on a phenomenological mathematical model of thrombus formation, coagulation and platelet function can be accurately measured in vitro in patient blood samples. When the device is integrated into an extracorporeal circuit in pig endotoxemia or heparin therapy models, it produces real-time readouts of alterations in coagulation ex vivo that are more reliable than standard clotting assays. Thus, this disposable device may be useful for personalized diagnostics and for real-time surveillance of antithrombotic therapy in clinic.

15 October 2021 in Science Advances
Verified
Journal Article
Open access
SXShangjing Xin
Shangjing Xin
KDKaivalya A. Deo
Kaivalya A. Deo
JDJing Dai
Jing Dai
NPNavaneeth Krishna Rajeeva Pandian
Navaneeth Krishna Rajeeva Pandian
DCDavid Chimene
David Chimene
DADaniel L. Alge
Daniel L. Alge
Bioprinting hydrogel microparticles requires consideration of size, stiffness, and nozzle geometry due to jamming effects.

27 July 2016 in Biomedical Microdevices
Verified
Journal Article
Open access
PDF file
AJAbhishek Jain
Abhishek Jain
AMAndries van der Meer
Andries van der Meer
APAnne-Laure Papa
Anne-Laure Papa
RBRiccardo Barrile
Riccardo Barrile
ALAngela Lai
Angela Lai
DIDonald E Ingber
Donald E Ingber
The vascular endothelium and shear stress are critical determinants of physiological hemostasis and platelet function in vivo, yet current diagnostic and monitoring devices do not fully incorporate endothelial function under flow in their assessment and, therefore, they can be unreliable and inaccurate. It is challenging to include the endothelium in assays for clinical laboratories or point-of-care settings because living cell cultures are not sufficiently robust. Here, we describe a microfluidic device that is lined by a human endothelium that is chemically fixed, but still retains its ability to modulate hemostasis under continuous flow in vitro even after few days of storage. This device lined with a fixed endothelium supports formation of platelet-rich thrombi in the presence of physiological shear, similar to a living arterial vessel. We demonstrate the potential clinical value of this device by showing that thrombus formation and platelet function can be measured within minutes using a small volume (0.5 mL) of whole blood taken from subjects receiving antiplatelet medications. The inclusion of a fixed endothelial microvessel will lead to biomimetic analytical devices that can potentially be used for diagnostics and point-of-care applications.