Yongjun Qiu

Dr. Yongjun Qiu


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2024 in Machines
Verified
Journal Article
Open access
PDF file
YPYan Peng
Yan Peng
JLJunde Liu
Junde Liu
HJHe Junjie
He Junjie
YQYongjun Qiu
Yongjun Qiu
LXLiu Xie
Liu Xie
YWYuhan Wang
Yuhan Wang
In order to ensure the safety of steel wire rope in various application scenarios, it is particularly important to quantitatively detect the defects of wire rope. Complex detection conditions affect the detection efficiency of wire rope. Therefore, based on the magnetic flux leakage method, this study proposes a method to identify the damage width of steel wire rope for multi-channel fusion of a Hall sensor array. Firstly, the Hall sensor array is used to capture the magnetic flux leakage data of steel wire rope; then, continuous wavelet transform is used to decompose the original data, and moving average filtering is used to denoise each component; the denoised components are merged and converted into a time spectrum, and the time spectrum is classified by ResNet50 image classification model to realize the detection of wire rope damage width. According to the dataset used in this study, the results show that the proposed method performs best in the mainstream noise reduction model; detection accuracy for the width of damage in steel wire ropes is 97%, which proves that the proposed method is effective and feasible.

31 October 2024 in Highlights in Science, Engineering and Technology
Verified
Journal Article
Open access
PDF file
DKDugang Kang
Dugang Kang
YQYongjun Qiu
Yongjun Qiu
LKLigui Kang
Ligui Kang
YHYanyun Huang
Yanyun Huang
LMLin Ma
Lin Ma
SHSong Huang
Song Huang
The fluctuation current introduced by renewable power sources often fluctuates in a wide power range due to their own fluctuation, greatly affecting the performance and safety of the electrolysis cell. Therefore, the input power of PEM water electrolysis process is variable, and it needs to be adjusted in combination with its dynamic characteristics during operation to ensure its performance and safety. In the transient model, research has found that under the condition of step voltage, the current density rapidly decreases, then rapidly increases, rises to the highest point, and slowly decreases before finally stabilizing. On the contrary, under the condition of step flow rate, the current density response is slow and takes about 8 seconds to stabilize.

31 October 2024 in Highlights in Science, Engineering and Technology
Verified
Journal Article
Open access
PDF file
CLChaojun Luo
Chaojun Luo
ZLZhangxu Liu
Zhangxu Liu
YQYongjun Qiu
Yongjun Qiu
ZWZhangjian Wang
Zhangjian Wang
DKDugang Kang
Dugang Kang
In recent years, the safety problems caused by frequent failures of old elevators have attracted increasing social attention. The safety evaluation of old elevators is an effective method to comprehensively judge the safety status of elevators. Through the statistics of the relevant data of the safety evaluation conclusions of more than 100 old elevators, this paper focuses on the analysis of the typical potential safety risks and puts forward practical and effective measures and suggestions, so as to provide effective guidance for ensuring the safe operation of old elevators.

30 June 2024 in Highlights in Science, Engineering and Technology
Verified
Journal Article
Open access
PDF file
LKLigui Kan
Ligui Kan
YQYongjun Qiu
Yongjun Qiu
DKDugang Kang
Dugang Kang
MLMa Lin
Ma Lin
YHYanyun Huang
Yanyun Huang
PYPengkai Yang
Pengkai Yang
This article comprehensively explores the risk prevention and control measures for equipment safety, ensuring the stability and safety of equipment operation. Firstly, a solution for the oxidation and aging issues of alloy materials is proposed, which involves surface treatment through electroplating metal and painting, with special attention paid to the protection of key components such as main and auxiliary steel and support columns. Secondly, the importance of connecting load-bearing components of the equipment was emphasized, and the stability and safety of the structure were improved through the use of high-strength bolts, nuts, and washers. In terms of maintenance of mechanical systems, regular lubrication of chains and sprockets, as well as scientific layout of electrical testing equipment, can ensure the safe operation of the equipment. The prevention, maintenance, monitoring, and early warning systems for improper personnel operation are very important and necessary.

26 September 2024
Verified
Conference Paper
Open access
PDF file
YPYan Peng
Yan Peng
YQYongjun Qiu
Yongjun Qiu
DKDugang Kang
Dugang Kang
YHYanyun Huang
Yanyun Huang
LMLin Ma
Lin Ma
SHSong Huang
Song Huang
In recent years, the study of clean energy, specifically hydrogen energy, has become increasingly prevalent. Significant advancements have been made in hydrogen production technologies, such as water electrolysis. Among these, Proton Exchange Membrane Water Electrolysis (PEMWE) is regarded as the most promising green hydrogen production technology for the future. However, the performance output of a PEM electrolyzer can vary with changes in parameters. This paper employs steady-state equations and COMSOL software to simulate changes in the porosity of the anode and cathode diffusion layers in a PEM electrolyzer. Findings indicate that a rise in the porosity of the anode diffusion layer enhances the electrolyzer’s performance. Conversely, increasing the porosity of the cathode diffusion layer has a minimal impact on the electrolyzer’s output performance.