Courtney Jarrahian

Ms. Courtney Jarrahian

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Journal of Controlled Release
Verified
Journal Article
Open access
PGPatricia González-Vázquez
Patricia González-Vázquez
Eneko LarrañetaEneko Larrañeta
Eneko Larrañeta
MMMaelíosa T.C. McCrudden
Maelíosa T.C. McCrudden
CJCourtney Jarrahian
Courtney Jarrahian
ARAnnie Rein-Weston
Annie Rein-Weston
Ryan DonnellyRyan Donnelly
Ryan Donnelly
Neonatal infections are a leading cause of childhood mortality in low-resource settings. World Health Organization guidelines for outpatient treatment of possible serious bacterial infection (PSBI) in neonates and young infants when referral for hospital treatment is not feasible include intramuscular gentamicin (GEN) and oral amoxicillin. GEN is supplied as an aqueous solution of gentamicin sulphate in vials or ampoules and requires health care workers to be trained in dose calculation or selection of an appropriate dose based on the patient's weight band and to have access to safe injection supplies and appropriate sharps disposal. A simplified formulation, packaging, and delivery method to treat PSBI in low-resource settings could decrease user error and expand access to lifesaving outpatient antibiotic treatment for infants with severe infection during the neonatal period. We developed dissolving polymeric microneedles (MN) arrays to deliver GEN transdermally. MN arrays were produced from aqueous blends containing 30% (w/w) of GEN and two polymers approved by the US Food and Drug Administration: sodium hyaluronate and poly(vinylpyrrolidone). The arrays (19×19 needles and 500μm height) were mechanically strong and were able to penetrate a skin simulant to a depth of 378μm. The MN arrays were tested in vitro using a Franz Cell setup delivering approximately 4.45mg of GEN over 6h. Finally, three different doses (low, medium, and high) of GEN delivered by MN arrays were tested in an animal model. Maximum plasma levels of GEN were dose-dependent and ranged between 2 and 5μg/mL. The time required to reach these levels post-MN array application ranged between 1 and 6h. This work demonstrated the potential of dissolving MN arrays to deliver GEN transdermally at therapeutic levels in vivo.

7 April 2011
Verified
Book Chapter
Closed access
PDF file
YKY. C. Kim
Y. C. Kim
CJCourtney Jarrahian
Courtney Jarrahian
DZD. Zehrung
D. Zehrung
SMS. Mitragotri
S. Mitragotri
MPMark R. Prausnitz
Mark R. Prausnitz

1 December 2010 in Journal of Controlled Release
Verified
Journal Article
Closed access
XCXianfeng Chen
Xianfeng Chen
AKAngela Shaulov Kask
Angela Shaulov Kask
MCMichael Crichton
Michael Crichton
CMCelia McNeilly
Celia McNeilly
SYSally Yukiko
Sally Yukiko
MKMark A.F. Kendall
Mark A.F. Kendall

1 April 2018 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
AHAaron R.J. Hutton
Aaron R.J. Hutton
HQHelen L. Quinn
Helen L. Quinn
PMPaul J. McCague
Paul J. McCague
CJCourtney Jarrahian
Courtney Jarrahian
ARAnnie Rein-Weston
Annie Rein-Weston
Ryan DonnellyRyan Donnelly
Ryan Donnelly
Vitamin K deficiency within neonates can result in vitamin K deficiency bleeding. Ensuring that newborns receive vitamin K is particularly critical in places where access to health care and blood products and transfusions is limited. The World Health Organization recommends that newborns receive a 1 mg intramuscular injection of vitamin K at birth. Evidence from multiple surveillance studies shows that the introduction of vitamin K prophylaxis reduces the incidence of vitamin K deficiency bleeding. Despite these recommendations, coverage of vitamin K prophylactic treatment in low-resource settings is limited. An intramuscular injection is the most common method of vitamin K administration in neonates. In low- and middle-income countries, needle sharing may occur, which may result in the spread of bloodborne diseases. The objective of our study was to investigate the manufacture of microneedles for the delivery of vitamin K. Following microneedle fabrication, we performed insertion studies to assess the microneedle's mechanical properties. Results indicate that vitamin K in a microneedle array was successfully delivered in vitro across neonatal porcine skin with 1.80 ± 0.08 mg delivered over 24 h. Therefore, this initial study shows that microneedles do have the potential to prevent vitamin K deficiency bleeding. Future work will assess delivery of vitamin K in microneedle array in vivo.

1 July 2013 in Vaccine
Verified
Journal Article
Closed access
DZDarin Zehrung
Darin Zehrung
CJCourtney Jarrahian
Courtney Jarrahian
AWAmy Wales
Amy Wales

1 June 2021 in Advanced Drug Delivery Reviews
Verified
Journal Article
Closed access
Alejandro ParedesAlejandro Paredes
Alejandro Paredes
IRInken K. Ramöller
Inken K. Ramöller
PMPeter E. McKenna
Peter E. McKenna
MAMarco T.A. Abbate
Marco T.A. Abbate
FVFabiana Volpe-Zanutto
Fabiana Volpe-Zanutto
Ryan DonnellyRyan Donnelly
Ryan Donnelly