Objective: To evaluate the marginal gap (MG) and absolute marginal discrepancy (MD) of full ceramic crowns with two finish line designs, shoulder and chamfer, using microcomputed tomography (micro-CT) before and after cementation. Materials and Methods: Sixty extracted human maxillary premolar teeth were divided into two groups based on the finish line design: Group I: 90° shoulder and Group II: 135° chamfer. The specimens were further grouped based on the type of full ceramic crown they received: Group A: Feldspathic Cerec inLab ceramic system, Group B: Cerec inLab aluminum oxide ceramic system and Group C: Lithium disilicate press ceramic system. Before cementation, five crowns from each group were scanned using micro-CT in two sections, sagittal and coronal, to determine the MG and MD values for four regions of the crown (sagittal buccal, sagittal lingual, coronal mesial and coronal distal). After cementation and thermal cycling, the scanning was repeated. Measurements were obtained from 10 points for each region, 80 points totally, to evaluate the MG and MD values. Files were processed using NRecon and CTAn software. Results were statistically analyzed using one- and two-way ANOVA and Tukey HSD tests (P = 0.05). Results: Full ceramic systems showed clinically acceptable marginal adaptation values. The Feldspathic Cerec inLab ceramic system generally presented the lowest variance, except in the MG values of the coronal mesial region. The MG and MD values of all ceramics increased significantly after cementation, except in the shoulder preparation design (sagittal buccal region) for MG and in the chamfer preparation design (sagittal lingual region) for MD values. Conclusions: Full-ceramic crowns showed clinically acceptable marginal adaptation values. The Feldspathic Cerec inLab ceramic system (Vitablocs Mark II) generally presented the lowest variance when compared with the other ceramics, except for the MG values on the mesial surface of the coronal section.
Objective. To determine the influence of the home bleaching agent, Opalescence PF, on the surface roughness and microhardness of glazed glassy matrix CAD‐CAM ceramics. Materials and Methods. The 28 sintered leucite‐ and lithium disilicate‐reinforced ceramic specimens (IPS Empress CAD and IPS e.max CAD) were divided into control and bleached groups. The home bleaching agent was applied to specimens of bleached groups for 7 days. The surface roughness and microhardness of all specimens were measured. A scanning electron microscope was used to evaluate the surface properties. The data were statistically analyzed by two‐way ANOVA. Results. The control e.max CAD showed the lowest surface roughness values. For both Empress and e.max CAD, surface roughness was significantly higher for the bleached group (p < 0.05). No significant differences in microhardness were observed. Conclusions. According to our study, patients should be careful when using home bleaching agents because whitening agents can affect the mechanical properties of full ceramic restorations like e.max CAD and Empress CAD. Ceramic polishing may be required in clinical situations where ceramic restorations are accidentally exposed to bleaching gels.
Objective. This research study investigated the effect of new decontamination protocols on the bonding capacity of saliva-contaminated monolithic zirconia (MZ) ceramics cemented with two different monomer-containing self-adhesive resin cements. Materials and Methods. Standardized tooth preparations (4 mm. axial height) were performed for eighty human maxillary premolars under constant water cooling system. Eighty monolithic zirconia crowns (Whitepeaks Supreme Monolith) ( groups) were manufactured by CAD-CAM. Specimens were kept in the artificial saliva at for 1 minute at 37°C except control groups. The specimens have not been prealumina blasted and grouped according to cleaning methods and resin cements: control groups (C) (no saliva (N) (CN) and 10-MDP (M) containing resin cement (CM), alumina blasted (ALN) and 10-MDP containing resin cement (ALM), zirconium oxide containing universal cleaning agent (IC) (N) (ICN) and 10-MDP containing resin cement (ICM), pumice (P)
Purpose Maintaining the surface quality of ceramic restorations after clinical adjustments is critical for both aesthetic outcomes and long-term oral health, yet the optimal approach to restoring gloss and smoothness remains unclear. The purpose of this study is to investigate the effect of different surface finishing and grinding procedures on the surface gloss and roughness of three different monolithic lithium disilicate ceramics and one monolithic ultra-translucent zirconia ceramic. Materials and Methods A total of 104 specimens (1.5 × 12 × 14 mm) were prepared from four ceramic materials: LiSi CEREC Tessera (CT), GC Initial LiSi (LS), IPS e.max CAD (EC), and zirconia disc (KATANA UTML (KAT)). Each was divided into two subgroups based on surface finishing (mechanical polishing or glazing; n = 10). Gloss and surface roughness were measured using a glossmeter and a profilometer, respectively. One specimen per subgroup was analyzed under SEM at ×1000 magnification. Results Gloss and roughness values were analyzed with the two-way robust ANOVA test and multiple comparisons were made with Bonferroni correction. The significance level was set at p < 0.05. Mechanical polishing, glazing, and repolishing increased the gloss values of the materials, with the KAT group achieving the highest gloss in the repolishing groups. The lowest gloss values were observed in the grinding groups. Additionally, these surface treatments reduced the roughness of the surface of all the materials. Conclusions Surface finishing procedures significantly influenced the gloss and roughness of monolithic lithium disilicate and zirconia ceramics. Mechanical polishing systems performed similarly or better than glazing. However, selecting an appropriate polishing system for each material is essential.
Background and Purpose: This study aimed to evaluate the flexural strength, color change and antimicrobial effect of silver–zeolite nanoparticles (NPs) in acrylic resin materials. Methods: Fifty-six disc-shaped acrylic resin samples were divided into four groups (n = 7) according to concentrations of silver–zeolite NPs (0%, 2%, 4%, 5%). Discs were contaminated with C. albicans and S. mutans. The antimicrobial effect was tested by inoculating contaminated discs on Tryptic soy agar (TSA), Sabouraud Dextrose Agar (SDA), Tryptic soy broth (TSB), and Sabouraud dextrose broth (SDB). Forty rectangular 65 × 10 × 2.5 mm acrylic resin specimens were also classified into four groups (n = 10) according to concentrations of silver–zeolite NPs. For the color change, L, a, and b values of rectangular specimens were examined with a spectrophotometer. A three-point bending test was also performed using a Devotrans device to determine the flexural bond strength of rectangular specimens. Scanning electron microscope analysis (SEM/EDX analysis) was also performed. Results: In this study, the antimicrobial effect increased with the concentration of silver–zeolite NPs added to acrylic resin discs. In our study, adding 2% silver–zeolite NPs was more effective against C. albicans. The antimicrobial effect against S. mutans increased with concentration of silver–zeolite NPs (<0.001). The colonization of C. albicans was significantly reduced by silver–zeolite NPs. A significant increase was observed in the color change as the nanoparticle percentage ratio increased (p < 0.001). The flexural strength values of the groups containing 2% and 4% nanoparticles were found to be clinically acceptable. Conclusions: The study showed that bacterial and fungal colonization is significantly reduced by adding silver–zeolite nanoparticles to acrylic resin discs. Based on its antimicrobial, physical, and mechanical properties, we recommend adding 2% silver–zeolite nanoparticles to the acrylic resin material for optimal results.
The objective of this study was to explore the effect of different surface treatments and bonding types on elemental composition and bond strength of dentin. Under water cooling, 1.5 mm of tooth structure containing just dentin was cut from 39 extracted human molars. Dentin surfaces were untreated (control) or treated by erbium: yttrium aluminum garnet or femtosecond laser (n = 13, each). One sample from each group underwent scanning electron microscopy. Then, dentin surfaces were bonded by Clearfil SE Bond or Clearfil SE Protect (n = 6, each). Energy dispersive X-ray spectroscopy was performed both after surface treatment and bonding application. The dual-polymerized resin cement was applied to dentin surfaces with a special teflon mold (diameter:3 mm × height:3 mm). After polymerization of the resin cement, shear force was applied at the resin cement-dentin interface. Elemental composition value (weight%) of dentin after surface treatment was analyzed by one-way analysis of variance (ANOVA), and the difference value in pre and post-bonding elemental composition by two-way ANOVA. Paired t-tests were executed to compare the weight% values of each element before and after each bonding application. Bond strength was analyzed by two-way ANOVA. The post-hoc test was Tukey’s honest significant difference test. Both laser treatments increased the mineral content of dentin, compared to the controls (P0.05). For resin cementation, either surface treatment is suitable. After laser treatment, Clearfil SE Bond is recommended over Clearfil SE Protect.