Purpose: The current review aims to summarize the international experience of the impact of adaptive radiotherapy on dosimetry and clinical and toxicity outcomes. Additionally, it might trigger Radiation Oncologists to use ART and evaluate whether ART improves target volume coverage and/or normal tissue sparing and, consequently, therapeutic results. Materials and methods: We conducted an electronic literature search of PubMed/MEDLINE and ScienceDirect from January 2007 to January 2023. The search adhered to the PRISMA guidelines and employed keywords such as ART, HNC, parotid gland, and target volume. Furthermore, we examined the reference lists for studies pertinent to the present review. This study included both retrospective and prospective studies that were considered for inclusion. Conclusion: ART replanning appears to be a sustainable strategy to minimize toxicity by improving normal tissue sparing. Furthermore, it can enhance target volume coverage by correctly determining the specific dose to be delivered to the tumor. In conclusion, this review confirmed that ART benefits dosimetric, clinical/therapeutic, and toxicity outcomes.
Radiotherapy (RT)-induced lymphopenia may hinder the anti-tumor immune response. Preoperative RT or chemo-RT (CRT) for locally advanced rectal cancer is a standard therapeutic approach, while immunotherapy has been approved for mismatch repair-deficient rectal tumors. We retrospectively analyzed 98 rectal adenocarcinoma patients undergoing neoadjuvant CRT with VMAT (groups A, B, C) or IMRT (group D) techniques, with four different RT schemes: group A (n = 24): 25 Gy/5 Gy/fraction plus a 0.2 Gy/fraction rectal tumor boost; group B (n = 22): 34 Gy/3.4 Gy/fraction, with a 1-week treatment break after the first five RT fractions; group C (n = 20): 46 Gy/2 Gy/fraction plus a 0.2 Gy/fraction rectal tumor boost; group D (n = 32): 45 Gy/1.8 Gy/fraction followed by 5.4 Gy/1.8 Gy/fraction to the rectal tumor. We examined the effect of the time-corrected normalized total dose (NTD-T) to the BM on lymphopenia. Groups A and B (hypofractionated RT) had significantly higher lymphocyte counts (LCs) after RT than groups C and D (p < 0.03). An inverse association between the LCs after RT and NTD-T was demonstrated (p = 0.01). An NTD-T threshold of 30 Gy delivered to 30% of the BM volume emerged as a potential constraint for RT planning, which could be successfully integrated in the RT plan. Hypofractionated and accelerated RT schemes, and BM-sparing techniques may reduce lymphocytic damage and prove critical for immuno-RT clinical trials.
The current work describes the implementation of the American Association of Physicists in Medicine (AAPM)'s Task Group 119 report on a volumetric phantom (Delta4, Scandidos, Uppsala, Sweden) following the stated dose goals, to evaluate the step-and-shoot intensity modulated radiation therapy (IMRT) system. Delta4 consists of diode detectors, lying on two crossed planes, measuring the delivered dose, and providing two-dimensional dosimetric information. Seven plans of different goals and complexity were performed, with individual structure sets. TG199 structure sets and plans were transferred and implemented on the Delta4 phantom taking into account its cylindrical geometry. All plans were delivered with a 6 MV linear accelerator equipped with multileaf collimator of 1 cm thickness. Plan results for each test met the recommended dose goals. The evaluation was performed in terms of dose deviation, distance to agreement, and gamma index passing rate. In all test cases, the gamma index passing rate was measured >90%. Delta4 phantom has proven to be fast, applicable, and reliable for the step-and-shoot IMRT commissioning following TG119's recommended tests. Although AAPM's TG119 report is referring to the implementation of test plans that do not correspond to patient plans, it could be used as an evaluation tool of various IMRT systems, considering the local treatment planning system and the delivery system.
We performed electronic research for articles published in PubMed, MEDLINE, and ScienceDirect databases from January 2004 to January 2023. The systematic review of twenty (20) peer-reviewed articles about dosimetric parameters and eight (8) articles about clinical outcomes confirmed the dosimetric advantages of ART through better target coverage and Organs at Risk (OARs) sparing, with subsequent benefits on decreased toxicity and improved clinical outcome, specifically local control of the disease. ART replanning is a sustainable strategy for minimizing toxicity by improving normal tissue sparing. Furthermore, it enhances target volume coverage by correctly determining the specific amount of dose to be delivered to the tumor. In conclusion, this review confirms that ART benefits dosimetric, clinical/therapeutic, and toxicity outcomes.