Burcu Batak

Dr. Burcu Batak

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
BBBurcu Batak
Burcu Batak
GÇGülce Çakmak
Gülce Çakmak
WJWilliam M. Johnston
William M. Johnston
BYBurak Yilmaz
Burak Yilmaz
High-performance polymers have been recommended by their manufacturers as a framework material for implant-supported fixed prostheses. However, little is known about the surface roughness of high-performance polymers in different compositions and whether they require layering with a composite resin or acrylic resin on the tissue surface. The purpose of this in vitro study was to evaluate the surface roughness of different computer-aided design and computer-aided manufacture (CAD-CAM) high-performance polymers and the effect of polishing on their surface roughness. Seventy high-performance polymer specimens (n=10) for 4 different polyetheretherketone (PEEK) brands (BRE, CP, ZZ, J), 1 polyetherketoneketone (PEKK) (PK), and 2 different fiber-reinforced composite resin (FRC) materials (T, TR) were milled from 7×8×30-mm CAD-CAM blocks. The surface roughness (Ra) of each specimen was measured on the same surfaces after milling (baseline) and after polishing by using a contact profilometer. Two-way repeated measures ANOVA (MIXED procedure) and the Bonferroni corrected t test (α=.05) were used to analyze the surface roughness data. No significant differences were found among high-performance polymers when the baseline surface roughness measurements of the materials were compared (P>.05). All materials (BRE, PK, CP, T, TR, ZZ), except for a PEEK material (J) (P<.05), had no significant differences in their surface roughness before and after polishing. After polishing, the surface roughness of the J PEEK material was higher than that of CP, PK, T, and ZZ (P<.05). The surface roughness of high-performance polymers in different compositions after milling was similar. Polishing increased the surface roughness of only one PEEK (J) material. All surface roughness values were above the clinical acceptability threshold of 0.2 μm.

1 March 2020 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
BBBurcu Batak
Burcu Batak
BYBurak Yilmaz
Burak Yilmaz
KSKarnik Shah
Karnik Shah
RRRajat Rathi
Rajat Rathi
MSMartin Schimmel
Martin Schimmel
LLLisa Lang
Lisa Lang

23 October 2019 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
BYBurak Yilmaz
Burak Yilmaz
BBBurcu Batak
Burcu Batak
RSRobert R. Seghi
Robert R. Seghi


1 January 2020 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
FAFunda Akaltan
Funda Akaltan
BBBurcu Batak
Burcu Batak
EOEce İrem Oğuz
Ece İrem Oğuz
KOKaan Orhan
Kaan Orhan

5 March 2021 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
BYBurak Yilmaz
Burak Yilmaz
BBBurcu Batak
Burcu Batak
RSRobert Seghi
Robert Seghi
WJWilliam M. Johnston
William M. Johnston
LLLisa A. Lang
Lisa A. Lang