Gerald Loeb

Dr. Gerald Loeb

orcid

Research Focus & Metrics

Academic Career Length

55Years (1972-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 1972 in Experimental Cell Research
Verified
Journal Article
Closed access
CTC Thomasjr
C Thomasjr
PSP Springer
P Springer
GLGerald Loeb
Gerald Loeb
YBY Berwaldnetter
Y Berwaldnetter
LOL Okun
L Okun

1 January 2008 in Advanced Robotics
Verified
Journal Article
Closed access
NWNicholas Wettels
Nicholas Wettels
VSVeronica J. Santos
Veronica J. Santos
RJRoland S. Johansson
Roland S. Johansson
GLGerald Loeb
Gerald Loeb
The performance of robotic and prosthetic hands in unstructured environments is severely limited by their having little or no tactile information compared to the rich tactile feedback of the human ...

1 January 1987 in Journal of Morphology
Verified
Journal Article
Closed access
PDF file
GLGerald Loeb
Gerald Loeb
CPC. A. Pratt
C. A. Pratt
CCC. M. Chanaud
C. M. Chanaud
FRF. J. R. Richmond
F. J. R. Richmond

23 May 2012 in Journal of Neuroscience
Verified
Journal Article
Open access
PDF file
ARAymar de Rugy
Aymar de Rugy
GLGerald Loeb
Gerald Loeb
TCTimothy J. Carroll
Timothy J. Carroll
When sharing load among multiple muscles, humans appear to select an optimal pattern of activation that minimizes costs such as the effort or variability of movement. How the nervous system achieves this behavior, however, is unknown. Here we show that contrary to predictions from optimal control theory, habitual muscle activation patterns are surprisingly robust to changes in limb biomechanics. We first developed a method to simulate joint forces in real time from electromyographic recordings of the wrist muscles. When the model was altered to simulate the effects of paralyzing a muscle, the subjects simply increased the recruitment of all muscles to accomplish the task, rather than recruiting only the useful muscles. When the model was altered to make the force output of one muscle unusually noisy, the subjects again persisted in recruiting all muscles rather than eliminating the noisy one. Such habitual coordination patterns were also unaffected by real modifications of biomechanics produced by selectively damaging a muscle without affecting sensory feedback. Subjects naturally use different patterns of muscle contraction to produce the same forces in different pronation–supination postures, but when the simulation was based on a posture different from the actual posture, the recruitment patterns tended to agree with the actual rather than the simulated posture. The results appear inconsistent with computation of motor programs by an optimal controller in the brain. Rather, the brain may learn and recall command programs that result in muscle coordination patterns generated by lower sensorimotor circuitry that are functionally “good-enough.”

15 April 1999 in Experimental Brain Research
Verified
Journal Article
Closed access
PDF file
GLGerald Loeb
Gerald Loeb
IBI. E. Brown
I. E. Brown
ECE. J. Cheng
E. J. Cheng

1 March 1977 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
GLGerald Loeb
Gerald Loeb
MBM. J. Bak
M. J. Bak
MSM. Salcman
M. Salcman
ESE. M. Schmidt
E. M. Schmidt
One of the major problems in the design of neurophysiologiv extracellular microelectrodes is the application and selective removal of the insulation. In addition to the usual problems of achieving pin-hole-free coatings and reproducible tip exposures and impedances, chronic electrode designshave the additional requirement of maintaining megohm levels of electrical isolation for months in vivo. A method of insulating finely tapered microelectrodes with complicated shapes by vapor condensation of Parylene-C is presented, along with a method for exposing controlled, reproducible lengths of their tips. In vivo and in vitro impedance tests and unit records obtained over 100 days in monkey motor cortex are presented. The electric arc process used to expose Parylene-covered iridium and tungsten microelectrodes is found to give cleaner recording surfaces with impedances lower than those obtainable with previously described methods. Chronic iridium microelectrodes so fabricated have recorded unit potentials and maintained constant impedances for over 4 months in vivo.