1 November 2013 in Biomaterials
Verified
Journal Article
Open access
KCKim Chaffin
Kim Chaffin
CWCharles L. Wilson
Charles L. Wilson
AHAdam K. Himes
Adam K. Himes
JDJames W. Dawson
James W. Dawson
THTarek D. Haddad
Tarek D. Haddad
NSNarendra K. Simha
Narendra K. Simha
Segmented polyurethane multiblock polymers containing polydimethylsiloxane and polyether soft segments form tough and easily processed thermoplastic elastomers (PDMS-urethanes). Two commercially available examples, PurSil 35 (denoted as P35) and Elast-Eon E2A (denoted as E2A), were evaluated for abrasion and fatigue resistance after immersion in 85 °C buffered water for up to 80 weeks. We previously reported that water exposure in these experiments resulted in a molar mass reduction, where the kinetics of the hydrolysis reaction is supported by a straight forward Arrhenius analysis over a range of accelerated temperatures (37-85 °C). We also showed that the ultimate tensile properties of P35 and E2A were significantly compromised when the molar mass was reduced. Here, we show that the reduction in molar mass also correlated with a reduction in both the abrasion and fatigue resistance. The instantaneous wear rate of both P35 and E2A, when exposed to the reciprocating motion of an ethylene tetrafluoroethylene (ETFE) jacketed cable, increased with the inverse of the number averaged molar mass (1/Mn). Both materials showed a change in the wear surface when the number-averaged molar mass was reduced to ≈ 16 kg/mole, where a smooth wear surface transitioned to a 'spalling-like' pattern, leaving the wear surface with ≈ 0.3 mm cracks that propagated beyond the contact surface. The fatigue crack growth rate for P35 and E2A also increased in proportion to 1/Mn, after the molar mass was reduced below a critical value of ≈30 kg/mole. Interestingly, this critical molar mass coincided with that at which the single cycle stress-strain response changed from strain hardening to strain softening. The changes in both abrasion and fatigue resistance, key predictors for long term reliability of cardiac leads, after exposure of this class of PDMS-urethanes to water suggests that these materials are susceptible to mechanical compromise in vivo.


16 April 2025 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Open access
IGIoan P. I. Gitsov
Ioan P. I. Gitsov
YLYunzhi Liu
Yunzhi Liu
DSDavid M. Saylor
David M. Saylor
AHAngela L. Hendrickx
Angela L. Hendrickx
AGAnn M. Gronda
Ann M. Gronda
KCKim Chaffin
Kim Chaffin
The United States Food and Drug Administration (FDA) recently announced an update to their 510(k) medical device sterility guidance to include vapor phase hydrogen peroxide (VH2O2) as an established ‘Category A’ sterilization process. This places VH2O2 in the same category as ethylene oxide (EO or EtO), which has demonstrated user and patient safety as well as microbiocidal effectiveness through scientific literature and FDA‐recognized consensus standards. For some implantable medical devices, the sterilant chemistry must diffuse through the polymers of construction to access sealed parts of the finished assembly to achieve an appropriate sterility assurance level. Diffusion of EO through materials has been well established over decades of successful use. However, the ability of VH2O2 to diffuse through materials of construction has not been demonstrated. In this work, we measured the diffusivity and permeability of VH2O2 for a series of increasing durometer poly(ether)urethanes (PEUs) commonly used in the construction of single‐use medical devices. The diffusion coefficients were 1 × 10−8 cm2/s for PEU75D, 2 × 10−8 cm2/s for PEU55D, and 5 × 10−8 cm2/s for PEU80A. The permeabilities were calculated to be 4.7 × 10−6 cm2/s and 1.3 × 10−5 cm2/s for PEU55D and PEU80A, respectively. For a typical cardiac or neuromodulation lead, the PEU80A wall thickness is on the order of 0.013 cm, resulting in penetration of hydrogen peroxide into the sealed construction in less than 10 min, a timeframe that is a fraction of the total sterilization cycle time.

1 January 2013
Verified
Book Chapter
Closed access
KCKim Chaffin
Kim Chaffin
CTCatherine Taylor
Catherine Taylor
TGT. Grailer
T. Grailer

23 May 2025 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Open access
ELEric K. Long
Eric K. Long
JHJoseph F. Hassler
Joseph F. Hassler
DSDavid M. Saylor
David M. Saylor
IGIoan P. I. Gitsov
Ioan P. I. Gitsov
LJLogan Jolliffe
Logan Jolliffe
KCKim Chaffin
Kim Chaffin
Medical devices should be biocompatible throughout the entire lifecycle, but the evaluation for biocompatibility is typically performed on a new, fully finished device. While long‐term implantable devices such as cardiac leads maintain function for more than a decade, studies have not addressed changes in extractable species throughout the implant life cycle. In this study, we performed extractables analysis on cardiac leads that were implanted in humans for times ranging from 3 to 130 months. The exhaustive extracts were analyzed using liquid chromatography coupled to mass spectrometry to identify and relatively quantify extractable species. Over implant times exceeding a decade, no new species were formed, and the quantity of each class of mobile species remained constant or decreased over time. Polyurethane oligomers, a byproduct of the polymerization route, generally remained at constant levels, suggesting that there is little to no driving force for them to enter the surrounding tissue. Small molecule additives, such as the antioxidant Irganox 1076, contained within the polyurethane outer coating, decreased at a rate that was consistent with diffusional release rather than reactive consumption. These results support two important conclusions. First, the chemical profile of the mobile species does not change over the implanted lifecycle, indicating the biocompatibility of durable cardiac leads does not change over time. Second, the toxicological assumption that all mobile species identified in exhaustive extractions of a new device are released upon implant is extremely conservative when contrasted with the diffusional release rates measured in the human explanted leads studied herein.

1 January 2009 in MRS Proceedings
Verified
Journal Article
Closed access
PDF file
JZJianbin Zhang
Jianbin Zhang
LLLian Luo
Lian Luo
SLSuping Lyu
Suping Lyu
BPBryant Pudil
Bryant Pudil
JSJim Schley
Jim Schley
RSRandy Sparer
Randy Sparer